References
- AccusorbMRI (homepage on the Internet) Available from: http://www.accusorb.com/index.htmlAccessed August 25, 2014
- InmanDMMaschinoSERF shielding in MRI for safety of implantable medical devices2008 Available from: http://www.google.com/patents/US20080023010Accessed March 12, 2014
- DörrTWeissIShielding apparatus and shielding structures for magnetic resonance imaging and method for operating a magnetic resonance imaging scanner2012 Available from: http://www.google.com/patents/EP2446923A1?cl=enAccessed March 12, 2014
- WilkoffBLAlbertTLazebnikMSafe magnetic resonance imaging scanning of patients with cardiac rhythm devices: a role for computer modelingHeart Rhythm201310121815182124096164
- LiuYShenJKainzWQianSWuWChenJNumerical investigations of MRI RF field induced heating for external fixation devicesBiomed Eng Online20131211223394173
- GornyKRPrestiMFGoerssSJMeasurements of RF heating during 3.0-T MRI of a pig implanted with deep brain stimulatorMagn Reson Imaging201331578378823228310
- GornyKRBernsteinMAFelmleeJPCalorimetric calibration of head coil SAR estimates displayed on a clinical MR scannerPhys Med Biol200853102565257618441413
- GornyKRBernsteinMAWatsonRE3 Tesla MRI of patients with a vagus nerve stimulator: initial experience using a T/R head coil under controlled conditionsJ Magn Reson Imaging201031247548120099360
- QianDEl-SharkawyA-MMBottomleyPAEdelsteinWAAn RF dosimeter for independent SAR measurement in MRI scannersMed Phys2013401212230324320534
- NehrkeKBörnertPDREAM – a novel approach for robust, ultrafast, multislice B(1) mappingMagn Reson Med20126851517152622252850
- SledJGPikeGBStanding-wave and RF penetration artifacts caused by elliptic geometry: an electrodynamic analysis of MRIIEEE Trans Med Imaging19981746536629845320
- FleysherRFleysherLIngleseMSodicksonDTROMBONE: T1-relaxation-oblivious mapping of transmit radio-frequency field (B1) for MRI at high magnetic fieldsMagn Reson Med201166248349121394765
- GilbertKMSchollTJChronikBARF coil loading measurements between 1 and 50 MHz to guide field-cycled MRI system designConcepts Magn Reson Part B Magn Reson Eng200833B31771191
- ASTM F2182-11. Standard test method for measurement of radio frequency induced heating on or near passive implants during magnetic resonance Available from: http://www.astm.org/Standards/F2182.htmAccessed August 25, 2014
- MatteiETriventiMCalcagniniGComplexity of MRI induced heating on metallic leads: experimental measurements of 374 configurationsBiomed Eng Online200871118315869
- ArmeneanCPerrinEArmeneanMBeufOPilleulFSaint-JalmesHRF-induced temperature elevation along metallic wires in clinical magnetic resonance imaging: influence of diameter and lengthMagn Reson Med20045251200120615508156