750
Views
12
CrossRef citations to date
0
Altmetric
Review

Emerging clinical applications of computed tomography

, , , , , , & show all
Pages 265-278 | Published online: 05 Jun 2015

References

  • CormackAMReconstruction of densities from their projections, with applications in radiological physicsPhys Med Biol1973181952074805109
  • HounsfieldGNComputerized transverse axial scanning (tomography) part 1. Description of the systemBr J Radiol197346101610224757352
  • CierniakRX-Ray Computed Tomography in Biomedical EngineeringLondon, UKSpringer-Verlag2011
  • RöntgenWCÜber eine neue Art von Strahlen. Sitzungsberichte der Physikalisch-medizinischen Gesellschaft zu Würzburg [on a new kind of rays]Science18963227231 German
  • ThomsonEStereoscopic roentgen picturesElectr Eng189621256
  • BushbergJTThe Essential Physics of Medical Imaging2nd edPhiladelphia, PA, USALippincott Williams and Wilkins2002
  • ChoZHJonesJPSinghMFoundations of Medical Imaging1st edNew York, NY, USAJohn Wiley and Sons1993
  • KakACSlanleyMPrinciples of Computerized Tomographic Imaging1st edNew York, NY, USAIEEE Press1988
  • GloverGHCompton scatter effects in CT reconstructionsMed Phys198298608677162472
  • KarçaaltıncabaMAktaşADual-energy CT revisited with multidetector CT: review of principles and clinical applicationsDiagn Interv Radiol20111718119420945292
  • KarenMHSheilaSFrankCMultidetector row CT: principles and clinical applicationsCrit Rev Comput Tomogr20024314318112233913
  • KazaRKPlattJFGoodsittMMEmerging techniques for dose optimization in abdominal CTRadiographics20143441724428277
  • CochetHDuboisRSacherFCardiac arrythmias: multimodal assessment integrating body surface ECG mapping into cardiac imagingRadiology201427123924724475841
  • GodoyMCNaidichDPMarchioriEBasic principles and postprocessing techniques of dual-energy CT: illustrated by selected congenital abnormalities of the thoraxJ Thorac Imaging20092415215919465844
  • AranSShaqdanKVAbujudehHHDual-energy computed tomography (DECT) in emergency radiology: basic principles, techniques, and limitationsEmerg Radiol20142139140524676736
  • JohnsonTRCDual-energy CT: general principlesAm J Roentgenol20121995 Suppl38
  • VoglTJSchulzBBauerRWDual-energy CT applications in head and neck imagingAJR Am J Roentgenol2012199S34S3923097166
  • TawfikAMKerlJMBauerRWDual-energy CT of head and neck cancer: average weighting of low- and high-voltage acquisitions to improve lesion delineation and image quality-initial clinical experienceInvest Radiol20124730631121577123
  • KangMParkCMLeeCHDual-energy CT: clinical applications in various pulmonary diseasesRadiographics20103068569820462988
  • BrownCLHartmanRPDzyubakOPDual-energy CT iodine overlay technique for characterization of renal masses as cyst or solid: a phantom feasibility studyEur Radiol2009191289129519153744
  • GraserAJohnsonTRHechtEMDual-energy CT in patients suspected of having renal masses: can virtual nonenhanced images replace true nonenhanced images?Radiology200925243344019487466
  • StolzmannPScheffelHRentschKDual-energy computed tomography for the differentiation of uric acid stones: ex vivo performance evaluationUrol Res20083613313818545993
  • StolzmannPLeschkaSScheffelHCharacterization of urinary stones with dual-energy CT: improved differentiation using a tin filterInvest Radiol2010451619996763
  • SilvaACMorseBGHaraAKPadenRGHongoNPavlicekWDual-energy (spectral) CT: applications in abdominal imagingRadiographics2011311031104621768237
  • FischerMAReinerCSRaptisDQuantification of liver iron content with CT-added value of dual-energyEur Radiol2011211727173221472472
  • StolzmannPFrauenfelderTPfammatterTEndoleaks after endovascular abdominal aortic aneurysm repair: detection with dual-energy dual-source CTRadiology200824968269118780822
  • ChandaranaHGodoyMCVlahosIAbdominal aorta: evaluation with dual-source dual-energy multidetector CT after endovascular repair of aneurysms – initial observationsRadiology200824969270018812561
  • RuzsicsBSchwarzFSchoepfUJComparison of dual-energy computed tomography of the heart with single photon emission computed tomography for assessment of coronary artery stenosis and of the myocardial blood supplyAm J Cardiol200910431832619616661
  • NagaoMKidoTWatanabeKFunctional assessment of coronary artery flow using adenosine stress dual-energy CT: a preliminary studyInt J Cardiovasc Imaging20112747148120686853
  • SchwarzFRuzsicsBSchoepfUJDual-energy CT of the heart – principles and protocolsEur J Radiol20086842343319008064
  • ZhangLJPengJWuSYYehBMZhouCSLuGMDual source dual-energy computed tomography of acute myocardial infarction: correlation with histopathologic findings in a canine modelInvest Radiol20104529029720421797
  • BauerRWKerlJMFischerNDual-energy CT for the assessment of chronic myocardial infarction in patients with chronic coronary artery disease: comparison with 3-T MRIAJR Am J Roentgenol201019563964620729440
  • BarretoMSchoenhagenPNairAPotential of dual-energy computed tomography to characterize atherosclerotic plaque: ex vivo assessment of human coronary arteries in comparison to histologyJ Cardiovasc Comput Tomogr2008223424219083956
  • BollDTMerkleEMPaulsonEKMirzaRAFleiterTRCalcified vascular plaque specimens: assessment with cardiac dual-energy multidetector CT in anthropomorphically moving heart phantomRadiology200824911912618710959
  • HazirolanTAkpinarBUnalSGümrükFHalilogluMAlibekSValue of dual energy computed tomography for detection of myocardial iron deposition in thalassaemia patients: initial experienceEur J Radiol20086844244518768275
  • IbrahimE-SHBowmanAWCharacterization of myocardial iron overload by dual-energy computed tomography compared to T2* MRI. A phantom studyConf Proc IEEE Eng Med Biol Soc201420145133513625571148
  • HenzlerTFinkCSchoenbergSOSchoepfUJDual-energy CT: radiation dose aspectsAm J Roentgenol2012199S16S2523097163
  • LinXZWuZYTaoRDual energy spectral CT imaging of insulinoma – value in preoperative diagnosis compared with conventional multi-detector CTEur J Radiol201282487249422153746
  • LeschkaSStolzmannPBaumüllerSPerformance of dual-energy CT with tin filter technology for the discrimination of renal cysts and enhancing massesAcad Radiol20101752653420207320
  • Van WerkhovenJMGaemperliOSchuijfJDMultislice computed tomography coronary angiography for risk stratification in patients with an intermediate pretest likelihoodHeart2009951607161119581272
  • HadamitzkyMFreissmuthBMeyerTPrognostic value of coronary computed tomographic angiography for prediction of cardiac events in patients with suspected coronary artery diseaseJACC Cardiovasc Imaging2009240441119580721
  • ShumanWPBranchKRMayJMProspective versus retrospective ECG gating for 64-detector CT of the coronary arteries: comparison of image quality and patient radiation doseRadiology200824843143718552312
  • SommerWHAlbrechtEBambergFFeasibility and radiation dose of high-pitch acquisition protocols in patients undergoing dual-source cardiac CTAJR Am J Roentgenol20101951306131221098188
  • EinsteinAJHenzlovaMJRajagopalanSEstimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiographyJAMA200729831732317635892
  • EinsteinAJSanzJDellegrottaglieSRadiation dose and cancer risk estimates in 16-slice computed tomography coronary angiographyJ Nucl Cardiol20081523224018371595
  • AchenbachSMarwanMSchepisTHigh pitch spiral acquisition: a new mode for coronary angiographyJ Cardiovasc Comput Tomogr20093117e219332343
  • ChinnaiyanKMBilolikarANWalshECT dose reduction using prospectively triggered or fast-pitch spiral technique employed in cardiothoracic imaging (the CT dose study)J Cardiovasc Comput Tomogr2014820521424939069
  • BruderHPetersilkerMMehldauHFlash imaging in dual source CT (DSCT). Proc SPIE 7258, Medical Imaging2009Physics of Medical Imaging, 72580D Available from: http://proceedings.spiedigitallibrary.org/proceeding.aspx?articleid=1335243Accessed May 9, 2015
  • ChinnaiyanKMBouraJADePetrisAProgressive radiation dose reduction from coronary computed tomography angiography in a statewide collaborative quality improvement program: results from the Advanced Cardiovascular Imaging ConsortiumCirc Cardiovasc Imaging20136646e65423926193
  • StaffordRJFuentesDElliottAAWeinbergJSAhrarKLaser-induced thermal therapy for tumor ablationCrit Rev Biomed Eng2010387910021175405
  • Lepetit-CoifféMLaumonierHSerorOReal-time monitoring of radiofrequency ablation of liver tumors using thermal-dose calculation by MR temperature imaging: initial results in nine patients, including follow-upEur Radiol20102019320119657650
  • SaccomandiPSchenaESilvestriSTechniques for temperature monitoring during laser-induced thermotherapy: an overviewInt J Hyperthermia20132960961924032415
  • VoglTJStraubREichlerKWoitaschekDMackMGMalignant liver tumors treated with MR imaging-guided laser-induced thermotherapy: experience with complications in 899 patients (2,520 lesions)Radiology200222536737712409568
  • FaniFSchenaESaccomandiPSilcestriSCT-based thermometry: an overviewInt J Hyperthermia20143021922724964063
  • PandeyaGGreuterMde JongKSchmidtBFlohrTOutkerkMFeasibility of noninvasive temperature assessment during radiofrequency liver ablation on computed tomographyJ Comput Assist Tomogr20113535636021586931
  • LiMAbi-JaoudehNKapoorATowards cone-beam CT thermometryProc SPIE2013867117
  • BydderGMKreelLThe temperature dependence of computed tomography attenuation valuesJ Comput Assist Tomogr19793506510457964
  • FalloneBGMoranPRPodgorsakEBNoninvasive thermometry with a clinical X-ray CT scannerMed Phys198297157217155074
  • MahnkenAHBrunersPCT thermometry: will it ever become ready for use?Int J Clin Pract201165Suppl 1711221155936
  • SchenaESaccomandiPGiurazzaFMonitoring of temperature increase and tissue vaporization during laser interstitial thermotherapy of ex vivo swine liver by computed tomographyConf Proc IEEE Eng Med Biol Soc2013201337838124109703
  • PandeyaGDKlaessensJHGreuterMJFeasibility of computed tomography based thermometry during interstitial laser heating in bovine liverEur Radiol2011211733173821432022
  • SchenaESaccomandiPGiurazzaFExperimental assessment of CT-based thermometry during laser ablation of porcine pancreasPhys Med Biol20135811223221023
  • AlfidiRJHaagaJMeaneyTFComputed tomography of the thorax and abdomen: a preliminary reportRadiology19751172572641178849
  • CrommelinDJStormGLuijtenP‘Personalized medicine’ through ‘personalized medicines’: time to integrate advanced, non-invasive imaging approaches and smart drug delivery systemsInt J Pharm20114155821320581
  • KatadaKAnnoHTakeshitaGDevelopment of real-time CT fluoroscopyNippon Igaku Hoshasen Gakkai Zasshi19945411721174 Japanese9261196
  • SartiMBrehmerWPGaySBLow-dose techniques in CT-guided interventionsRadiographics2012321109111922786997
  • GrassoRFCazzatoRLLuppiGPercutaneous lung biopsies: performance of an optical CT-based navigation system with a low-dose protocolEur Radiol2013233071307623783784
  • BeyerTPichlerBA decade of combined imaging: from a PET attached to a CT to a PET inside an MREur J Nucl Med Mol Imaging200936S1S219104807
  • KinahanPTownsendDBeyerTSashinDAttenuation correction for a combined 3D PET/CT scannerMed Phys199825204620539800714
  • PelcNJHybrid x-ray/MR system and other hybrid imaging modalitiesMedical Imaging 2003: Physiology and Function: Methods, Systems, and Applications Clough AVAminiAAProceedings of SPIESan Diego, CA5031February 15; 2003
  • GangulyAWenZDanielBTruly hybrid X-ray/MR imaging: towards a streamlined clinical systemAcad Radiol2005121167117716099685
  • BaikSKimHSJeongMHInternational consortium on phase contrast imaging and radiology beamline at the Pohang light sourceRev Sci Instrum20047543554358
  • SnigirevASnigirevaIKohnVOn the possibilities of x-ray phase contrast microimaging by coherent high-energy synchrotron radiationRev Sci Instrum19956654865492
  • CastelliETonuttiMArfelliFMammography with synchrotron radiation: first clinical experience with phase-detection techniqueRadiology201125968469421436089
  • PisanoEDJohnstonREChapmanDHuman breast cancer specimens: diffraction-enhanced imaging with histologic correlation-improved conspicuity of lesion detail compared with digital radiographyRadiology200021489590110715065
  • ShikhalievPMShannonGFPhoton counting spectral CT versus conventional CT: comparative evaluation for breast imaging applicationPhys Med Biol2011561905193021364268
  • FeuerleinSRoesslEProksaRMultienergy photon-counting K-edge imaging: potential for improved luminal depiction in vascular imagingRadiology20082491010101618849505
  • SchlomkaJRoesslEDorscheidRExperimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomographyPhys Med Biol2008534031403718612175
  • SinghSKalraMKHsiehJAbdominal CT: comparison of adaptive statistical iterative and filtered back projection reconstruction techniquesRadiology201025737338320829535
  • Berrington de GonzálezAMaheshMKimKPProjected cancer risks from computed tomographic scans performed in the United States in 2007Arch Intern Med20091692071207720008689