89
Views
2
CrossRef citations to date
0
Altmetric
Original Research

Biomechanical evaluation of three fixation modalities for preperitoneal inguinal hernia repair: a 24-hour postoperative study in pigs

, &
Pages 437-444 | Published online: 09 Dec 2014

References

  • EU Hernia Trialists CollaborationLaparoscopic compared with open methods of groin hernia repair: systematic review of randomized controlled trialsBr J Surg200087786086710931019
  • FrännebyUSandblomGNordinPNyrénOGunnarssonURisk factors for long-term pain after hernia surgeryAnn Surg2006244221221916858183
  • EU Hernia Trialists CollaborationMesh compared with non-mesh methods of open groin hernia repair: systematic review of randomized controlled trialsBr J Surg200087785485910931018
  • EU Hernia Trialists CollaborationRepair of groin hernia with synthetic mesh: meta-analysis of randomized controlled trialsAnn Surg2002235332233211882753
  • ByrdJFAgeeNSwanRZEvaluation of absorbable and permanent mesh fixation devices: adhesion formation and mechanical strengthHernia201115555355821594698
  • BansalVKMisraMCBabuDA prospective, randomized comparison of long-term outcomes: chronic groin pain and quality of life following totally extraperitoneal (TEP) and transabdominal pre-peritoneal (TAPP) laparoscopic inguinal hernia repairSurg Endosc20132772373238223389072
  • TolverMARosenbergJBisgaardTEarly pain after laparoscopic inguinal hernia repair. A qualitative systematic reviewActa Anaesthesiol Scand201256554955722260427
  • IsmailMGargPLaparoscopic inguinal total extraperitoneal hernia repair under spinal anesthesia without mesh fixation in 1,220 hernia repairsHernia200913211511919005613
  • FortelnyRHPetter-PuchnerAHGlaserKSRedlHUse of fibrin sealant (Tisseel/Tissucol) in hernia repair: a systematic reviewSurg Endosc20122671803181222278103
  • SajidMSLadwaNKalraLMcFallMBaigMKSainsPA meta-analysis examining the use of tacker mesh fixation versus glue mesh fixation in laparoscopic inguinal hernia repairAm J Surg2013206110311123388426
  • SchwabRSchumacherOJungeKBinneböselMKlingeUSchumpelickVFibrin sealant for mesh fixation in Lichtenstein repair: biomechanical analysis of different techniquesHernia200711213914517252181
  • KingsnorthAGingell-LittlejohnMNienhuijsSRandomized controlled multicenter international clinical trial of self-gripping Parietex™ ProGrip™ polyester mesh versus lightweight polypropylene mesh in open inguinal hernia repair: interim results at 3 monthsHernia201216328729422453675
  • DuffyAJHogleNJLaPerleKMFowlerDLComparison of two composite meshes using two fixation devices in a porcine laparoscopic ventral hernia repair modelHernia20048435836415290611
  • KrpataDMBlatnikJAHarthKCPhillipsMSNovitskyYWRosenMJEvaluation of fibrin sealant for biologic mesh fixation at the hiatus in a porcine modelSurg Endosc201226113120312622538698
  • McGintyJJHogleNJMcCarthyHFowlerDLA comparative study of adhesion formation and abdominal wall ingrowth after laparoscopic ventral hernia repair in a porcine model using multiple types of meshSurgi Endosc2005196786790
  • FortelnyRHPetter-PuchnerAHFergusonJA comparative biomechanical evaluation of hernia mesh fixation by fibrin sealantJ Surg Res2011171257658120869077
  • MelmanLJenkinsEDDeekenCREvaluation of acute fixation strength for mechanical tacking devices and fibrin sealant versus polypropylene suture for laparoscopic ventral hernia repairSurg Innov201017428529020817641
  • RiederEStoiberMScheiklVMesh fixation in laparoscopic incisional hernia repair: glue fixation provides attachment strength similar to absorbable tacks but differs substantially in different meshesJ Am Coll Surg20112121808621036072
  • Schug-PassCLippertHKöckerlingFFixation of mesh to the peritoneum using a fibrin glue: investigations with a biomechanical model and an experimental laparoscopic porcine modelSurg Endosc200923122809281522219021
  • FortunyGRodríguez-NavarroJSusínALópez-CanoMSimulation and study of the behaviour of the transversalis fascia in protecting against the genesis of inguinal herniasJ Biomech200942142263226719665137
  • GuérinGTurquierFImpact of the defect size, the mesh overlap and the fixation depth on ventral hernia repairs: a combined experimental and numerical approachHernia201317564765523456147
  • Hernández-GascónBGrasaJPeñaEPascualGBellónJMCalvoBNumerical modelling of the abdominal wall applied to hernia surgeryJ Biomech201245S567
  • LubowieckaISzymczakCTomaszewskaAŚmietańskiMMathematical study of a tissue-implant connection in a ventral hernia repair in a context of the system’s parametersProc Appl Math Mech200991167168
  • BinneböselMRoschRJungeKBiomechanical analyses of overlap and mesh dislocation in an incisional hernia model in vitroSurgery2007142336537117723888
  • PodwojewskiFOtténioMBeillasPGuérinGTurquierFMittonDMechanical response of animal abdominal walls in vitro: evaluation of the influence of a hernia defect and a repair with a mesh implanted intraperitoneallyJ Biomech201346356156623099202
  • SchwabRSchumacherOJungeKBiomechanical analyses of mesh fixation in TAPP and TEP hernia repairSurg Endosc200822373173817623239
  • CobbWSBurnsJMKercherKWMatthewsBDJames NortonHTodd HenifordBNormal intraabdominal pressure in healthy adultsJ Surg Res2005129223123516140336
  • BellowsCFSmithAMalsburyJHeltonWSRepair of incisional hernias with biological prosthesis: a systematic review of current evidenceAm J Surg201320518510122867726
  • SlaterNJvan der KolkMHendriksTvan GoorHBleichrodtRPBiologic grafts for ventral hernia repair: a systematic reviewAm J Surg2013205222023023200988
  • SadavaEEKrpataDMGaoYSchomischSRosenMJNovitskyYWLaparoscopic mechanical fixation devices: does firing angle matter?Surg Endosc20132762076208123299138
  • KatkhoudaNMavorEFriedlanderMHUse of fibrin sealant for prosthetic mesh fixation in laparoscopic extraperitoneal inguinal hernia repairAnn Surg20012331182511141220
  • KatkhoudaNA new technique for laparoscopic hernia repair using fibrin sealantSurg Technol Int20041212012615455316
  • HelvindNMAndresenKRosenbergJLower reoperation rates with the use of fibrin sealant versus tacks for mesh fixationSurg Endosc201327114184419123719975
  • TolverMARosenbergJJuulPBisgaardTRandomized clinical trial of fibrin glue versus tacked fixation in laparoscopic groin hernia repairSurg Endosc20132782727273323355162
  • CampanelliGPascualMHHoeferlinARandomized, controlled, blinded trial of Tisseel/Tissucol for mesh fixation in patients undergoing Lichtenstein technique for primary inguinal hernia repair: results of the TIMELI trialAnn Surg2012255465065722395092
  • KaulAHutflessSLeHStaple versus fibrin glue fixation in laparoscopic total extraperitoneal repair of inguinal hernia: a systematic review and meta-analysisSurg Endosc20122651269127822350225
  • Schug-PassCJacobDALippertHKöckerlingFDifferences in biomechanical stability using various fibrin glue compositions for mesh fixation in endoscopic inguinal hernia repairSurg Endosc201226113282328622648108
  • SilvermanRPPassarettiDHuangWRandolphMAYaremchukMJInjectable tissue-engineered cartilage using a fibrin glue polymerPlast Reconstr Surg199910371809181810359239
  • KroezMLangWDickneiteGWound healing and degradation of the fibrin sealant Beriplast P following partial liver resection in rabbitsWound Repair Regen200513331832315953052
  • SandersDLNienhuijsSZiprinPMiserezMGingell-LittlejohnMSmedsSRandomized clinical trial comparing self-gripping mesh with suture fixation of lightweight polypropylene mesh in open inguinal hernia repairBr J Surg2014101111373138225146918
  • CambalMZoncaPHrbatyBComparison of self-gripping mesh with mesh fixation with fibrin-glue in laparoscopic hernia repair (TAPP)Bratisl Lek Listy2012113210310722394041