97
Views
2
CrossRef citations to date
0
Altmetric
Original Research

Diathermy for 23-gauge sclerotomy: a functional and morphologic study to avoid ocular hypotony

ORCID Icon, , ORCID Icon, ORCID Icon, ORCID Icon &
Pages 1703-1710 | Published online: 04 Sep 2019

Reference

  • Fuji GY, De Juan E Jr., Humayun MS, et al. Initial experience using the transconjunctival sutureless vitrectomy system for vitreoretinal surgery. Ophthalmology. 2002;109:1814–1820. doi:10.1016/s0161-6420(02)01119-3
  • Recchia FM, Scott IU, Brown GC, Brown MM, Ho AC, Ip MS. Small-gauge pars plana vitrectomy: a report by the American Academy of Ophthalmology. Ophthalmology. 2010;117:1851–1857. doi:10.1016/j.ophtha.2010.06.014
  • Meyer CH, Rodrigues EB, Schmidt JC, Hörle S, Kroll P. Sutureless vitrectomy surgery. Ophthalmology. 2003;110:2427–2428. doi:10.1016/j.ophtha.2003.09.004
  • Reibaldi M, Longo A, Reibaldi A, et al. Diathermy of leaking sclerotomy after 23-gauge transconjunctival pars plana vitrectomy. Retina. 2013;33:939–945. doi:10.1097/IAE.0b013e3182725d65
  • Kim MJ, Park KH, Hwang JM, Yu HG, Yu YS, Chung H. The safety and efficacy of transconjunctival sutureless 23-gauge vitrectomy. Korean J Ophthalmol. 2007;21:201–207. doi:10.3341/kjo.2007.21.4.201
  • Fortun JA, Grossniklaus HE, Wabner KA, Dou C, Olsen TW, Hubbard GB. The effect of air tamponade on the ingress of ocular surface pathogens in sutureless transconjunctival microincisional vitrectomy. Retina. 2013;33:566–570. doi:10.1097/IAE.0b013e31826710c0
  • Barak Y, Lee ES, Schaal S. Sealing, effect of external diathermy on leaking sclerotomies after small-gauge vitrectomy: a clinicopathological report. JAMA Ophthalmol. 2014;132:891–892. doi:10.1001/jamaophthalmol.2014.341
  • Woo SJ, Park KH, Hwang JM, Kim JH, Yu YS, Chung H. Risk factors associated with sclerotomy leakage and postoperative hypotony after 23-gauge transconjunctival sutureless vitrectomy. Retina. 2009;29:456–463. doi:10.1097/IAE.0b013e318195cb28
  • Parolini B, Prigione G, Romanelli F, Cereda MG, Sartore M, Pertile G. Postoperative complications and intraocular pressure in 943 consecutive cases of 23-gauge transconjunctival pars planavitrectomy with 1-year follow-up. Retina. 2010;30:107–111. doi:10.1097/IAE.0b013e3181b21082
  • Boscia F, Besozzi G, Recchimurzo N, Sborgia L, Furino C. Cauterization for the prevention of leaking sclerotomies after 23-gauge transconjunctival pars planavitrectomy: an easy way to obtain sclerotomy closure. Retina. 2011;31:988–990. doi:10.1097/IAE.0b013e31821361a5
  • Lee BR, Song Y. Releasable suture technique for the prevention of incompetent wound closure in transconjunctival vitrectomy. Retina. 2008;28:1163–1165. doi:10.1097/IAE.0b013e3181840b80
  • Chieh JJ, Rogers AH, Wiegand TW, Baumal CR, Reichel E, Duker JS. Short-term safety of 23-gauge single-step transconjunctival vitrectomy surgery. Retina. 2009;29:1486–1490. doi:10.1097/IAE.0b013e3181aa8e6c
  • Veritti D, Sarao V, Lanzetta P. A propensity-score matching comparison between 27-gauge and 25-gauge vitrectomy systems for the repair of primary rhegmatogenous retinal detachment. J Ophthalmol. 2019;1–38. doi:10.1155/2019/3120960
  • Yoon YH, Kim DS, Kim JG, Hwang J-U. Sutureless vitreoretinal surgery using a new 25-gauge transconjunctival system. Comparison between 20-gauge technique. Ophthalmic Surg Lasers Imaging. 2006;37:12–19.
  • Amato JE, Akduman L. Incidence of complications in 25-gauge transconjunctival sutureless vitrectomy based on the surgical indications. Ophthalmic Surg Lasers Imaging. 2007;38:100–102.
  • Rodrigues EB, Meyer CH, Schmidt JC, Hoerle S, Kroll P. Unsealed sclerotomy after intravitreal injection with a 30-gauge needle. Retina. 2004;24:810–812.
  • Javey G, Rigi M, Barkmeier AJ, Heffez JL, Carvounis PE. Sclerotomy leakage in transconjunctival small-gauge pars plana vitrectomy: effect of removing the cannula over the light pipe. Retina. 2017;37:1079–1083. doi:10.1097/IAE.0000000000001310
  • Küçük E, Yılmaz U, Zor KR, Kalaycı D, Sarıkatipoğlu H. Risk factors for suture requirement and early hypotony in 23-gauge vitrectomy for complex vitreoretinal diseases. Int Ophthalmol. 2017;37:989–994. doi:10.1007/s10792-016-0361-x
  • Duval R, Hui JM, Rezaei KA. Rate of sclerotomy suturing in 23-gauge primary vitrectomy. Retina. 2014;34:679–683. doi:10.1097/IAE.0b013e3182a48972