110
Views
0
CrossRef citations to date
0
Altmetric
Original Research

Scleral Tonometry Precision During Scleral Lens Wear: A Pilot Study

ORCID Icon, & ORCID Icon
Pages 341-350 | Published online: 31 Dec 2021

References

  • Fogt JS, Nau CB, Schornack M, Shorter E, Nau A, Harthan JS. Comparison of pneumatonometry and transpalpebral tonometry measurements of intraocular pressure during scleral lens wear. Optom Vis Sci. 2020;97(9):711–719. doi:10.1097/OPX.0000000000001574
  • Nau CB, Schornack MM, McLaren JW, Sit AJ. Intraocular pressure after 2 hours of small-diameter scleral lens wear. Eye Cont Lens. 2016;42(6):350–353. doi:10.1097/ICL.0000000000000214
  • Kramer EG, Vincent SJ. Intraocular pressure changes in neophyte scleral lens wearers: a prospective study. Cont Lens Anterior Eye. 2020;43(6):609–612. doi:10.1016/j.clae.2020.05.010
  • Formisano M, Franzone F, Alisi L, Pistella S, Spadea L. Effects of scleral contact lenses for keratoconus management on visual quality and intraocular pressure. Ther Clin Risk Manag. 2021;17. doi:10.2147/TCRM.S293425
  • Fedotova K, Zhu W, Astakhov S, Novikov SA, Grabovetskiy VR, Nikolaenko VP. Intraocular pressure with miniscleral contact lenses. Vestn Oftalmol. 2021;137(2):52–58. doi:10.17116/oftalma202113702152
  • Michaud L, Samaha D, Giasson CJ. Intra-ocular pressure variation associated with the wear of scleral lenses of different diameters. Cont Lens Anterior Eye. 2019;42(1):104–110. doi:10.1016/j.clae.2018.07.004
  • Agranat JS, Kitos NR, Jacobs DS. Prosthetic replacement of the ocular surface ecosystem: impact at 5 years. Br J Ophthalmol. 2016;100(9):1171–1175. doi:10.1136/bjophthalmol-2015-307483
  • Tono-Pen AVIA ® Tonometer User’s Guide [Manual on the Internet]. AMETEK, Inc; 2017. Available from: http://doclibrary.com/MSC167/PRM/68E3892-Rev-J-UG-AVIA4540.pdf. Accessed September 14, 2021. 
  • Model 30 TM Pneumatonometer User’s Guide [Manual on the Internet]. AMETEK, Inc; 2017. Available from: https://lombartinstrument.com/store/pub/media/wysiwyg/Model-30-Users-Guide.pdf. Accessed September 14, 2021.
  • Aitsebaomo AP, Wong-Powell J, Miller W, Amir F. Influence of scleral lens on intraocular pressure. J Cont Lens Res Sci. 2019;3(1):e1–e9. doi:10.22374/jclrs.v3i1.34
  • Walker MK, Pardon LP, Redfern R, Patel N. IOP and optic nerve head morphology during scleral lens wear. Optom Vis Sci. 2020;97(9):661–668. doi:10.1097/OPX.0000000000001567
  • Shahnazi KC, Isozaki VL, Chiu GB. Effect of scleral lens wear on central corneal thickness and intraocular pressure in patients with ocular surface disease. Eye Cont Lens. 2020;46(6):341–347. doi:10.1097/ICL.0000000000000670
  • Kolin T, Wedemeyer LL, Kolin E, Braun Y. Comparison of scleral and corneal Tono-Pen readings. J Am Assoc Pediatr Ophthalmol Strabismus. 2003;7(4):291–292. doi:10.1016/S1091-8531(03)00147-2
  • Khan JA. Comparison of oculab Tono-Pen readings obtained from various corneal and scleral locations. Arch Ophthalmol. 1991;109(10):1444. doi:10.1001/archopht.1991.01080100124057
  • Kuo DS, Ou Y, Jeng BH, et al. Correlation of serial scleral and corneal pneumatonometry. Ophthalmology. 2015;122(9):1771–1776. doi:10.1016/j.ophtha.2015.05.033
  • Badakere SV, Choudhari NS, Rao HL, Chary CR, Garudadri CS, Senthil S. Comparison of scleral Tono-Pen intraocular pressure measurements with Goldmann applanation tonometry. Optom Vis Sci. 2018;95(2):129–135. doi:10.1097/OPX.0000000000001174
  • Dielemans I, Vingerling JR, Hofman A, Grobbee DE, de Jong PTVM. Reliability of intraocular pressure measurement with the Goldmann applanation tonometer in epidemiological studies. Graefes Arch Clin Exp Ophthalmol. 1994;232(3):141–144. doi:10.1007/BF00176782
  • Altinkaynak H, Kocasarac C, Dundar H, et al. Which tonometry in eyes with keratoconus? Eye. 2016;30(3):431–437. doi:10.1038/eye.2015.248
  • Lam AKC, Chen D. Effect of ocular massage on intraocular pressure and corneal biomechanics. Eye. 2007;21(9):1245–1246. doi:10.1038/sj.eye.6702928
  • Ruland K, Olayanju J, Borras T, Grewal DS, Fleischman D. Accuracy of Tonopen versus iCare in human cadaveric eyes with edematous corneas over a wide range of intraocular pressures. J Glaucoma. 2019;28(5):e82–e85. doi:10.1097/IJG.0000000000001162
  • Nguyen K, Lee J, Richter GM, Chiu GB. The effect of scleral lens wear on optic disc perfusion measured by optical coherence tomography angiography (OCTA). Global Specialty Lens Symposium. USC Roski Eye Institute; 2021.