148
Views
0
CrossRef citations to date
0
Altmetric
Original Research

Trial Tibial Inserts May Result in Different Knee Kinematics from Final Poly Inserts in Total Knee Arthroplasty

ORCID Icon, , , ORCID Icon &
Pages 81-88 | Published online: 28 Jun 2021

References

  • Inacio MCS, Paxton EW, Graves SE, Namba RS, Nemes S. Projected increase in total knee arthroplasty in the United States - an alternative projection model. Osteoarthritis Cartilage. 2017;25(11):1797–1803. doi:10.1016/j.joca.2017.07.022
  • Bourne RB, Chesworth BM, Davis AM, Mahomed NN, Charron KDJ. Patient satisfaction after total knee arthroplasty: who is satisfied and who is not? Clin Orthop. 2010;468(1):57–63. doi:10.1007/s11999-009-1119-9
  • Van Onsem S, Verstraete M, Van Eenoo W, Van Der Straeten C, Victor J. Are TKA kinematics during closed kinetic chain exercises associated with patient-reported outcomes? A preliminary analysis. Clin Orthop Relat Res. 2019;17.
  • Risitano S, Karamian B, Indelli PF. Intraoperative load-sensing drives the level of constraint in primary total knee arthroplasty: surgical technique and review of the literature. J Clin Orthop Trauma. 2017;8(3):265–269. doi:10.1016/j.jcot.2017.06.004
  • Angerame MR, Holst DC, Jennings JM, Komistek RD, Dennis DA. Total knee arthroplasty kinematics. J Arthroplasty. 2019;34(10):2502–2510. doi:10.1016/j.arth.2019.05.037
  • Sidhu SP, Moslemian A, Yamomo G, et al. Lateral subvastus lateralis versus medial parapatellar approach for total knee arthroplasty: a cadaveric biomechanical study. Knee. 2020;27(6):1735–1745. doi:10.1016/j.knee.2020.09.022
  • Willing R, Moslemian A, Yamomo G, Wood T, Howard J, Lanting B. Condylar-stabilized TKR may not fully compensate for PCL-deficiency: an in vitro cadaver study. J Orthop Res. 2019;37(10):2172–2181. doi:10.1002/jor.24392
  • Advanced Mechanical Technology, Inc. VIVOTM, bringing new life to joint motion simulation. AMTI; 2013. https://www.amti.jp/AMTI-VIVO-Brochure-Rev2-HiRes.pdf. Accessed June 21, 2021.
  • Grood ES, Suntay WJ. A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. J Biomech Eng. 1983;105(2):136–144. doi:10.1115/1.3138397
  • Blankevoort L, Huiskes R. Ligament-bone interaction in a three-dimensional model of the knee. J Biomech Eng. 1991;113(3):263–269. doi:10.1115/1.2894883
  • Bloemker KH, Guess TM, Maletsky L, Dodd K. Computational knee ligament modeling using experimentally determined zero-load lengths. Open Biomed Eng J. 2012;6:33–41. doi:10.2174/1874120701206010033
  • Willing R, Walker PS. Measuring the sensitivity of total knee replacement kinematics and laxity to soft tissue imbalances. J Biomech. 2018;77:62–68. doi:10.1016/j.jbiomech.2018.06.019
  • Sharkey PF, Hozack WJ, Rothman RH, Shastri S, Jacoby SM, Insall Award paper. Why are total knee arthroplasties failing today? Clin Orthop. 2002;404:7–13. doi:10.1097/00003086-200211000-00003
  • Chow JC, Breslauer L. The use of intraoperative sensors significantly increases the patient-reported rate of improvement in primary total knee arthroplasty. Orthopedics. 2017;40(4):e648–51. doi:10.3928/01477447-20170503-01