113
Views
19
CrossRef citations to date
0
Altmetric
Case Series

The King Vision™ video laryngoscope for awake intubation: series of cases and literature review

&
Pages 475-478 | Published online: 23 Jun 2014

References

  • RosenstockCVThøgersenBAfshariAChristensenALEriksenCGätkeMRAwake fiberoptic or awake video laryngoscopic tracheal intubation in patients with anticipated difficult airway managementAnesthesiology20121161210121622487805
  • AndruszkiewiczPDecMKanskiABeclerRAwake fibreoptic intubationAnestezjol Intens Ter201042246250
  • WadelekJAirway local anaesthesia for awake flexible fiberoptic endotracheal intubationAnesthesiol and Rescue2010499110
  • El-TahanMRDoyleDJKhidrAMAbdulshafiMRegalMAOthmanMSUse of the King Vision™ video laryngoscope to facilitate fibreoptic intubation in critical tracheal stenosis proves superior to the GlideScopeCan J Anaesth20146121321424218194
  • DimitriouVKZogogiannisIDLiotiriDGAwake tracheal intubation using the Airtraq laryngoscope: a case seriesActa Anaesthesiol Scand20095396496719496763
  • XueFSLiaoXYuanYJLiuJHWangQNasotracheal intubation using the Airtraq® optical laryngoscope in patients with a difficult airwayCan J Anaesth20115840640821264557
  • AsaiTPentax-AWS video laryngoscope for awake nasal intubation in patients with unstable necksBr J Anaesth201010410811119923133
  • SuzukiAKunisawaTTakahataOIwasakiHNozakiKHendersonJJPentax-AWS (Airway Scope) for awake tracheal intubationJ Clin Anesth20071964264318083485
  • SuzukiATeraoMAizawaKSasakawaTHendersonJJIwasakiHPentax-AWS Airway Scope as an alternative for awake flexible fiberoptic intubation of a morbidly obese patient in the semi-sitting positionJ Anesth20092316216319234847
  • SasanoNYamauchiHFujitaYFailure of the Airway Scope to reach the larynxCan J Anaesth20075477477517766752
  • JarviKHillermannCDanhaRMendoncaCAwake intubation with the Pentax Airway Scope – initial experience on 17 patients: 19AP5-3Eur J Anaesth201128235
  • GaszynskaEWieczorekAGaszynskiTAwake non-fibroscopic endotracheal intubation in patients with severely restricted mouth opening – alternative devices: series of cases and literature reviewCent Eur J Med2014In press
  • UsluBDamgaard NielsenRKristensenBBMcGrath video laryngoscope for awake tracheal intubation in a patient with severe ankylosing spondylitisBr J Anaesth201010411811920007801
  • SchoettkerPBathoryIBroomeMUse of the nasotracheal Airtraq® to assist difficult nasal fibreoptic intubationCan J Anaesth20085588419050101
  • XueFSLiCWZhangGHGlideScope-assisted awake fibreoptic intubation: initial experience in 13 patientsAnaesthesia2006611014101516978330
  • ChoiGSParkSILeeEHYoonSHAwake GlideScope® intubation in a patient with a huge and fixed supraglottic mass – a case reportKorean J Anesthesiol201059SupplS26S2921286452
  • RaiMRParryTMDombrovskisAWarnerOJRemifentanil target-controlled infusion vs propofol target-controlled infusion for conscious sedation for awake fibreoptic intubation: a double-blinded randomized controlled trialBr J Anaesth200810012513018037667
  • SukhupragarnWChurnchongkolkulWGlidescope intubation after failed fiberoptic intubationPaediatr Anaesth20102090190220716090
  • JeyadossJNanjappaNNemethDAwake intubation using Pentax-AWS video laryngoscope after failed fibreoptic intubation in a morbidly obese patient with a massive thyroid tumour and tracheal compressionAnaesth Intensive Care20113931131221485687
  • Lasinska-KowaraMKarwackiZLapinskiMComplications after using the Airtraq laryngoscope for predicted difficult intubationAnesthesiol Intensive Ther2013453840