266
Views
12
CrossRef citations to date
0
Altmetric
Original Research

Validation of four devices: Omron M6 Comfort, Omron HEM-7420, Withings BP-800, and Polygreen KP-7670 for home blood pressure measurement according to the European Society of Hypertension International Protocol

, , , , , , & show all
Pages 33-44 | Published online: 16 Jan 2014

References

  • ManciaGFagardRNarkiewiczK2013 ESH/ESC Guidelines for the Management of Arterial Hypertension. The Task Force for the Management of Arterial Hypertension of the European Society of Hypertension (ESH) and of the European Society of Cardiology (ESC)J Hypertens2013311281135723817082
  • ChobanianABakrisGBlackHSeventh Report of the Joint National Committee on Prevention, Detection, Evaluation and Treatment of High Blood PressureHypertension2003421206125214656957
  • AsmarRZanchettiAGuidelines for the use of self-blood pressure monitoring: a summary report of the first international consensus conferenceJ Hypertens20001849350810826551
  • ParatiGStergiouGAsmarREuropean Society of Hypertension guidelines for blood pressure monitoring at home: a summary report of the Second International Consensus Conference on Home Blood Pressure MonitoringJ Hypertens2008261505153018622223
  • O’BrienEAsmarRBeilinLon behalf of the European Society of Hypertension Working Group on Blood Pressure MonitoringPractice guidelines of the European Society of Hypertension for clinic, ambulatory and self blood pressure measurementJ Hypertens20052369770115775768
  • National Institute for Health and Care ExcellenceClinical guidelines 127. Hypertension: clinical management of primary hypertension in adults2011 Available from: http://www.nice.org.uk/CG127Accessed November 12, 2013
  • PickeringTHallJLawrenceARecommendations for blood pressure measurement in humans and experimental animals. Part 1. A statement for professionals from the American Heart Association Council on high blood pressure researchHypertension20054514216115611362
  • O’BrienEPetrieJLittlerWABlood Pressure Measurement Recommendations of the British Hypertension SocietyLondon, UKBMJ Publishing Group1997
  • O’BrienEPetrieJLittlerWAThe British Hypertension Society Protocol for the evaluation of blood pressure measuring devicesJ Hypertens199311Suppl 2S43S62
  • Association for the Advancement of Medical InstrumentationAmerican National Standard: non-invasive sphygmomanometers – part 2: clinical validation of automated measurement type; ANSI/AAMI/ISO20098106081062 Available from: www.aami.org/subscriptions/cdchart.pdfAccessed December 12, 2013
  • O’BrienEPickeringTAsmarRWorking Group on Blood Pressure Monitoring of the European Society of Hypertension International protocol for validation of blood pressure measuring devices in adultsBlood Press Monit2002731712040236
  • O’BrienEAtkinsNStergiouGWorking Group on Blood Pressure Monitoring of the European Society of Hypertension. European Society of Hypertension International Protocol Revision 2010 for the validation of blood pressure measuring devices in adultsBlood Press Monit201015233820110786
  • Groupe d’Evaluation et de Mesure de la Société Française d’Hypertension Artérielle. La prise de la tension artérielle au cabinet edical [Measurements of blood pressure in clinic]2001RanDMeudon, France
  • VieraAHinderliterAValidation of the HEM-780REL with easy wrap cuff for self-measurement of blood pressure according to the European Society of Hypertension International protocolBlood Press Monit20071233533817890973
  • BonsoESaladiniFZanierAAccuracy of a single rigid conical cuff with standard-size bladder coupled to an automatic oscillometric device over a wide range of arm circumferencesHypertens Res2010111186119120686489