59
Views
0
CrossRef citations to date
0
Altmetric
Review

Single photon emission computed tomography: An alternative imaging modality in left ventricular evaluation

, &
Pages 1069-1072 | Published online: 10 Oct 2008

References

  • AktaŞAYalçinHKoyuncuA2005The influence of post-exercise cardiac changes on thallium-gated myocardial perfusion scintigraphy findings in normal subjectsNucl Med Commun261091415657502
  • AlbrechtssonUEskilssonJLomskyM1982Comparison of left ventricular ejection fraction assessed by radionuclide angiocardiog-raphy, echocardiography and contrast angiocardiographyActa Med Scand211147527080860
  • BarkhausenJRuehmSGGoyenM2001MR evaluation of ventricular function: true fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: feasibility studyRadiology219264911274568
  • Borges-NetoS1993Perfusion and function assessment by nuclear cardiology techniquesCurr Opin Cardiol1258169429831
  • ChanJJenkinsCKhafagiF2006What Is the optimal clinical technique for measurement of left ventricular volume after myocardial infarction? A comparative study of 3-dimensional echocardiography, single photon emission computed tomography, and cardiac magnetic resonance imagingJ Am Soc Echocardiogr1919220116455424
  • DebrunDTherainFNguyenLD2005Volume measurements in nuclear medicine gated SPECT and 4D echocardiography: validation using a dynamic cardiac phantomInt J Cardiovasc Imaging212394716015435
  • DePueyEGNicholsKDobrinskyC1993Left ventricular ejection fraction assessed from gated technetium-99m-sestamibi SPECTJ Nucl Med34187168229227
  • FaberTLStokelyEMCorbettJR1988Surface detection in dynamic tomographic myocardial perfusion images by relaxation labelingSPLE 1001. Visual Communications and Image Processing297301
  • FaberTLStokelyEMPeshockRM1991A model-based four-dimensional left ventricular surface detectorIEEE Trans Med Imaging10321918222833
  • FaberTLCookeDRFolksRD1999Left ventricular function and perfusion from gated SPECT perfusion images: An integrated methodJ Nucl Med40650910210225
  • GermanoGKiatHKavanaghPB1995Automatic quantification of ejection fraction from gated myocardial perfusion SPECTJ Nucl Med362138477472611
  • GopalASKingDLKatzJ1992Three dimensional echocardiographic volume computation by polyhedral surface reconstruction: in vitro validation and comparison to magnetic resonance imagingJ Am Soc Echocardiogr5115241571165
  • Habash-BseisoDERokeyRBergerCJ2005Accuracy of noninvasive ejection fraction measurement in a large community-based clinicClin Med Res3758216012124
  • HandschumacherMDLethorJPSiuSC1993A new fully integrated system for three-dimensional echocardiographic reconstruction: validation for ventricular volume with application in human subjectsJ Am Coll Cardiol21743538436757
  • HyunIYKwanJParkKS2001Reproducibility of Tl-201 and Tc-99m sestamibi gated myocardial perfusion SPECT measurement of myocardial functionJ Nucl Cardiol8182711295696
  • JohnsonLLVerdescaSAAudeWY1997Postischemic stunning can affect left ventricular ejection fraction and regional wall motion on post-stress gated sestamibi tomogramsJ Am Coll Cardiol30164189385888
  • JonesRHJohnsonSHBigelowC1991Exercise radionuclide angiocardiography predicts cardiac death in patients with coronary artery diseaseCirculation841528
  • KanayamaSMatsunariIKajinamiK2007Comparison of gated N-13 ammonia PET and gated Tc-99m sestamibi SPECT for quantitative analysis of global and regional left ventricular functionJ Nucl Cardiol14680717826321
  • LuPLiuXShiR1994Comparison of tomographic and planar radionuclide ventriculography in the assessment of regional left ventricular function in patients with left ventricular aneurysm before and after surgeryJ Nucl Cardiol1537459420748
  • MassardoTJaimovichRLavadosH2007Comparison of radionu-clide ventriculography using SPECT and planar techniques in different cardiac conditionsEur J Nucl Med Mol Imaging3417354617579852
  • MeleDTeoliRCittantiC2004Assessment of left ventricular volume and function by integration of simplified 3D echocardiography, tissue harmonic imaging and automated extraction of endocardial bordersInt J Cardiovasc Imaging2019120215139533
  • MeineTJHansonMWBorges-Neto2004The additive value of combined assessment of myocardial perfusion and ventricular function studiesJ Nucl Med451721415471840
  • MochizukiTMuraseKTanakaH1997Assessment of left ventricular volume using ECG-gated SPECT with technetium-99m-MIBI and technetium-99m tetrofosminJ Nucl Med385378998150
  • NicholsKDePueyEGRozanskiA1997Image enhancement of severely hypoperfused myocardia for computation of tomographic ejection fractionJ Nucl Med381411179293799
  • NicholsKTamisJDePueyEG1998Relationship of gated SPECT ventricular function parameters to angiographic measurementsJ Nucl Cardiol52953039669584
  • NosirYFFiorettiPMVletterWB1996Accurate measurement of left ventricular ejection fraction by three-dimensional echocardiography. A comparison with radionuclide angiographyCirculation94460668759089
  • PflugfelderPWSechtemUPWhiteRD1988Quantification of regional myocardial function by rapid cine MR imagingAJR Am J Roentgenol15052393257602
  • SalustriAKofflardMJRoelandtJR1996Assessment of left ventricular outflow in hypertrophic cardiomyopathy using anyplane and paraplane analysis of three-dimensional echocardiographyAm J Cardiol7846288752194
  • SchaeferWMLipkeCSANowarkB2003Validation of an evaluation routine for left ventricular volumes, ejection fraction and wall motion from gated cardiac FDG PET: a comparison with cardiac magnetic resonance imagingEur J Nucl Med Mol Imaging305455312589480
  • SchaeferWMLipkeCSStandkeD2005Quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPECT: MRI validation and comparison of the Emory Cardiac Tool Box with QGS and 4D-MSPECTJ Nucl Med4612566316085580
  • SiuSCLevineRARiveraJM1995Three-dimensional echocar-diography improves noninvasive assessment of left ventricular volume and performanceAm Heart J130812227572591
  • SteggerLLipkeCSKiesP2007Quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPECT: validation of an elastic surface model approach in comparison to cardiac magnetic resonance imaging, 4D-MSPECT and QGSEur J Nucl Med Mol Imaging34900917216166
  • TeichholzLEKreulenTHermanMV1976Problems in echocar-diographic volume determinations: echocardiographic-angiographic correlations in the presence or absence of asynergyAm J Cardiol377111244736
  • VourvouriECPoldermansDBaxJJ2001Evaluation of left ventricular function and volumes in patients with ischaemic cardiomyopa-thy: gated single-photon emission computed tomography versus two dimensional echocardiographyEur J Nucl Med2816101511702101
  • YalçinFShiotaTOdabashianJ2000Comparison by real-time three-dimensional echocardiography of left ventricular geometry in hypertrophic cardiomyopathy versus secondary left ventricular hypertrophyAm J Cardiol851035810760354
  • YoshiokaJHasegawaSYamaguchiH1999Left ventricular volumes and ejection fraction calculated from quantitative electrocardiographic- gated 99mTc-Tetrofosmin myocardial SPECTJ Nucl Med401693810520710