References
- van Aken J. Geometrical errors in lateral skull x-ray projections. Nederl. T. Tandheelk. 1963; 70: 18–30
- Atwood D. A. A cephalometric study of the clinical rest position of the mandible. Part II. The variability in the rate of bone loss following the removal of occlusal contacts. J. prost. Dent. 1957; 7: 544–552
- Atwood D. A. Some clinical factors related to rate of resorption of residual ridges. J. prost. Dent. 1962; 12: 441–450
- Barber T. K., Pruzansky S., Lauterstein A., Kindelsperger R. Application of Roent-genographic Cephalometry to Pedodontic Research. J. Dent. Child. 1960; 27: 97–106
- Barber T. K., Pruzansky S., Kindelsperger R. An evaluation of the oblique Cephalometric Film. J. Dent Child. 1961; 28: 94–105
- Björk A. The face in profile. Svensk tandl. T. 1947; 40, suppl. B
- Björk A. Facial growth in man, studied with the aid of metallic implants. Acta odont. scand. 1955; 24: 9–34
- Björk A. Variations in the growth pattern of the human mandible: Longitudinal radiographic study by the implant methods. J. dent. Res. 1963; 42: 400–411
- Björk A. Sutural growth of the Upper Face studied by the Implant Method. Trans. Europ. orth. Soc. 1964; 49–65
- Carlsson G. E. Error in X-ray cephalometry. Odont. T. 1967; 75: 99–129
- Carlsson G. E., Bergman B., Hedegård B. Changes in Contour of the maxillary alveolar Process under Immediate Dentures. Acta odont. scand. 1967; 25: 1–31
- Carlsson G. E., Persson G. Morphologic changes of the mandible after extraction and wearing of dentures. Odont. Rev. 1967; 18: 27–54
- Carlsson G-E., Ragnarson N., Åstrand P. Changes in height of the alveolar process in edentulous segments. Odont. T. 1967; 75: 193–208
- Cartwright L.J., Harvold E. P. Improved Radiographic Results in Cephalometry through the use of High Kilovoltage. J. Canad. dent. Ass. 1954; 20: 261–163
- Graber T. M. Orthodontics 2. ed. Philadelphia-London 1966
- Harvold E. P., Rolling S. The use of high kilovoltage and logetronic prints in cephalometry. A way to improve detail definition and reduce radiation. Trans. Europ. orth. Soc. 1962; 204–107
- Hatton M-E., Grainger R. M. Reliability of measurements from Cephalograms at the Burlington Orthodontic Research Centre. J. dent. Res. 1958; 37: 853–859
- Hedegård B. Some observations on tissue changes with immediate maxillary dentures. Dent. Pract. dent. Rec. 1962; 13: 70–78
- Israel H. Radiogrammetric Replicability and direct validity of small mandibular measurements in the 45-degree Projection. J. dent. Res. 1966; 45: 1570
- Koski K. Kefalometrisessä röntgenkuvauksessa esiintyvien projektiovirheiden merkityksestä mittaustarkkuuden kannalta. Suom. hammaslääk. toim. 1954; 49: 85–89
- Margolis H. I. Standardized x-ray cephalographics. Amer J. Orth. 1940; 2♀: 725–740
- Nawrath K. Möglichkeiten und Grenzen der röntgenologischen Kephaloraetrie. Habilitationsschrift, Mainz 1961
- Savara B. S., Tracy W. E., Miller P. A. Analysis of errors in cephalometric measurements of three dimensional distances on the human mandible. Arch, oral Biol. 1966; 11: 209–217
- Solow B. The pattern of craniofacial associations. Acta odont. scand. 1966; 24, Suppl. 46
- Tallgren A. The reduction in face height of edentulous and partially edentulous subjects during long-term denture wear. Acta odont. scand. 1966; 24: 195–239
- Wictor in L. Bone resorption in cases with complete upper denture. Acta radiol. (Stockh.) 1964, suppl. 228