References
- Albrektsson T, Zarb G, Worthington P, Eriksson RA. The long-term efficacy of currently used dental implants: a review and proposed criteria of success. Int J Oral Maxillofac Implants 1986;1:11–25.
- Donath K, Laass M, Gunzl HJ. The histopathology of different foreigh-body reactions to oral soft tissue and bone tissue. Virchows Archiv Pathol Anat 1992;420:131–7.
- Cooper L, Felton DA, Kugelberg CF, Ellner S, Chaffee N, Molina AL, A multicenter 12-month evaluation of single-tooth implants restoration 3 weeks after 1-stage surgery. Int J Oral Maxillofac Implants 2001;16:182.
- Fazel A, Aalai S, Rismanchian M. Effect of macro-design of immediately loaded implants on micromotion and stress distribution in surrounding bone using finite element analysis. Implant Dent 2009;18:345.
- Brochu J, Anderson J, Zarb G. The influence of early loading on bony crest height and stability: a pilot study. Int J Prosthodont 2005;18:506.
- Pilliar RM, Lee JM, Maniatopoulos C. Observations on the effect of movement on bone ingrowth into porous-surfaced implants. Clin Orthop Relat Res 1986;5:108–13.
- Viceconti M, Muccini R, Bernakiewicz M, Baleani M, Cristofolini L. Large sliding contact elements accurately predict levels of bone-implant micromotion relevant to osseointegration. J Biomech 2000;33:1611–18.
- Brunski JB. Avoid pitfalls overloading and micromotion of intraosseous implants. Dent Implantol Update 1993;4:77–81.
- Chong W, Davliakos JP, Fischman B, Immediate loading. Implant Dent 2002;11:315–23.
- Lindhe J, Lang NP, Karring T. Clinical periodontology and implant dentistry. Oxford: Blackwell Publishing; 2003. p 279–95.
- Tu MG, Hsu JT, Fuh LJ, Lin DJ, Huang HL. Effects of cortical bone thickness and implant length on bone strain and interfacial micromotion in an immediately loaded implant. Int J Oral Maxillofac Implants 2010;25:706–14.
- Fazel A, Aalai S, Rismanchian M, Sadr-Eshkevari P. Micromotion and stress distribution of immediate loaded implants: a finite element analysis. Clin Implant Dent Relat Res 2009;11:267–71.
- Ho GW, Matinlinna JP. Insights on porcelain as a dental material. Part I: ceramic material types in dentistry. Silicon 2011; in press; DOI: 10.1007/s12633–011–9079–6.
- Liu D, Matinlinna JP, Pow EHN. Insights into porcelain zirconia bonding. J Adhes Sci Techn 2011; submitted 2011.
- Choi AH, Ben-Nissan B, Conway RC. Three-dimensional modelling and finite element analysis of the human mandible during clenching. Aust Dent J 2005;50:42–8.
- Choi AH, Matinlinna JP, Ben-Nissan B. Finite element stress analysis of Ti-6Al-4V and partially stabilized zirconia dental implant during clenching. Acta Odont Scand 2011; Early Online, 1–9.
- Arendts FJ, Sigolotto C. Standard measurements, elastic values and tensile strength behavior of the human mandible, a contribution to the biomechanics of the mandible - I. Biomed Tech 1989;34:248–55.
- Arendts FJ, Sigolotto C. Mechanical characteristics of the human mandible and study of in vivo behavior of compact bone tissue, a contribution to the description of biomechanics of the mandible - II. Biomed Tech 1990;35:123–30.
- Weinstein AM, Klawitter JJ, Cook SD. Implant-bone interface characteristics of bioglass dental implants. J Biomed Mater Res 1980;14:23–9.
- Cook SD, Weinstein AM, Klawitter JJ. Parameters affecting the stress distribution around LTI carbon and aluminium oxide dental implants. J Biomed Mater Res 1982;16:875–85.
- Piconi C, Maccauro G. Zirconia as a ceramic biomaterial. Biomaterials 1999;20:1–25.
- Callister WD. Materials in science and engineering - an introduction. 7th ed. New York: Wiley & Sons; 2007.
- Reilly SB, Burstein AH. The elastic and ultimate properties of compact bone tissue. J Biomech 1975;8:393–405.
- Akca K, Iplikcipglu H. Finite element stress analysis of the influence of staggered versus straight placement of dental implants. Int J Oral Maxillofac Implants 2001;16:722–30.
- Mainland D, Hiltz EJ. Forces exerted on the human mandible by the muscles of mastication. J Dent Res 1934;14:107–24.
- Barbenel JC. The biomechanics of the temporomandibular joint: a theoretical study. J Biomech 1972;5:251–6.
- Schumacher GH. Funktionelle morphologie der kinnmuskulatur. Jena: Fisher; 1961.
- Pruim GJ, De Jongh HJ, Ten Bosch JJ. Forces acting on the mandible during bilateral static bite at different bite force levels. J Biomech 1980;13:755–63.
- Poiate IA, de Vasconcellos AB, de Santana RB, Poiate E. Three-dimensional stress distribution in the human periodontal ligament in masticatory, parafunctional, and trauma loads: finite element analysis. J Periodontol 2009;80:1859–67.