References
- Albé-Fessard D., Fessard A. Thalamic integrations and their consequences at the telencephalic level. Progr. Brain Res. 1963; 1: 115–148
- Albé-Fessard D. Organisation of somatic central projections. Contrib. Sens. Physiol. 1967; 2: 101–167
- Beagley H.A., Knight J.J. Changes in auditory evoked response with intensity. J. Laryng. Otol. 1967a; 81: 861–873
- Beagley H.A., Knight J.J. The auditory evoked cortical response as an index of hearing in practical audiometry. J. Laryng. Otol. 1967b; 81: 347–351
- Beagley H.A., Kellogg S.E. A comparison of evoked responses and subjective auditory threshold. Int. Audiol. 1969; 8: 345–353
- Burian K., Gestring G.F., Hruby S. Clinical experience with the EEG-computer audiometry. Int. Audiol. 1969; 8: 633–638
- Burian K, Gestring G.F. Discrepancies between subjective and objective acoustic thresholds. Arch. Ohr.Nas.-KehlkHeilk. 1971; 198: 73–84
- Ciganek L. Evoked potentials in man: interaction of sound and light. Electroenceph. clin. Neurophysiol. 1966; 21: 28–33
- Davis P.A. Effects of acoustic stimuli on the waking human brain. J. Neurophysiol. 1939; 2: 494–499
- Davis H., Davis P.A., Loomis A.L., Harvey E.N., Hobart G. Electrical reaction of the human brain to auditory stimulation during sleep. J. Neurophysiol. 1939; 2: 500–514
- Davis H., Truman M., Nobuo Y., Stanley Z. The slow response of the human cortex to auditory stimuli: recovery process. Electroenceph. clin. Neurophysiol. 1966; 21: 105–113
- Davis H., Hirsch S.K., Shelnutt J., Bowers C. Further validation of evoked response audiometry (ERA). J. Speech and Hearing Res. 1967; 10: 717–732
- Davis H. Averaged-evoked-response EEG audiometry in North America. Acta otolaryng., Stockh. 1968; 65: 79–85
- Derbyshire A.J., Fraser A.A., McDermott M., Bridge A. Audiometric measurements by electroencephalography. Electroenceph. clin. Neurophysiol. 1956; 8: 467–478
- Derbyshire A.J., Farely J.C. Sampling auditory responses at the cortical level. Ann. Otol. Rhinol. Laryng., St. Louis 1959; 68: 675–698
- Dimitrijevi M.R., Faganel J., Gregorič M., Nathan P.W., Trontelj J.K. Habituation: effects of regular and stochastic stimulation. J. Neurol. Neurosurg. Psychiat. 1972; 35: 234–242
- Fruhstorfer H. Habituation and dishabituation of the human vertex response. Electroenceph. clin. Neurophysiol. 1971; 30: 306–312
- Larsson L.-E. Electroencephalographic response to peripheral nerve stimulation in man. Electroenceph. clin. Neurophysiol. 1953; 5: 377–384
- Larsson L.-E. Correlation between the psychological significance of stimuli and the magnitudes of the startle blink and evoked EEG potentials in man. Acta physiol. stand. 1960; 48: 276–294
- Larsson L.-E., Prevec T.S. Somato-sensory response to mechanical stimulation as recorded in the human EEG. Electroenceph. clin. Neurophysiol. 1970; 28: 162–172
- Moruzzi G., Magoun H.W. Brain stem reticular formation and activation of EEG. Electroenceph. clin. Neurophysiol. 1949; 1: 455–472
- Öhman A., Lader M. Selective attention and 'habituation' of the auditory averaged evoked response in humans. Physiol. Behav. 1972; 8: 79–85
- Picton T.W., Goodman W.S., Bryce D.P. Amplitude of evoked response to tones of high intensity. Acta oto-laryng., Stockh. 1970; 70: 77–82
- Prevec T.S., Dimitruevi M.R. Cerebralni evocirani potencial u audiometriji. Elektrofiziologija 1969; 1: 5–15
- Rapin I. Evoked responses to click in a group of children with communication disorders. Ann. N.Y. Acad. Sci. 1964; 112: 182–203
- Rapin I., Schimmel H., Cohen M.M. Reliability in detecting the auditory evoked response (AER) for audiometry in sleeping subjects. Electroenceph. clin. Neurophysiol. 1972; 32: 521–528
- Ritter W., Vaughan H. G., Jr., Costa L.D. Orientating and habituation to auditory stimuli: a study of short-term changes in averaged evoked responses. Electroenceph. clin. Neurophysiol. 1968; 25: 550–556
- Rose D.E., Keating L.W., Hedgecock L.D., Miller K.E., Schreurs K.K. A comparison of evoked response audiometry and routine clinical audiometry. Audiology 1972; 11: 238–243
- Rose D.E., Keating L.W., Hedgecock L.D., Schreurs K.K., Miller K.E. Aspects of acoustically evoked responses: Inter-judge and intra-judge reliability. Arch. Otolaryng. 1971; 94: 347–350
- Smith D.B., Allison T., Goff W.R., Principato J.J. Human odorant evoked responses: effects of trigeminal or olfactory deficit. Electroenceph. clin. Neurophysiol. 1971; 30: 313–317
- Spreng M, Keidel W.D. Separierung von Cerebroaudiogramm (CAG), Neuroaudiogramm (NAG) und Otoaudiogramm (OAG) in der objektiven Audiometrie. Arch. Ohr.Nas.-KehlkHeilk. 1967; 189: 225–246
- Taguchi K., Goodman W.S., Brummitt W.M. Evoked response audiometry in mentally retarded children. Acta oto-laryng., Stockh. 1970; 70: 190–196
- Trontelj J., Dimitrijevi M.R., Prevec T.S. A mechanic stimulator for eliciting tendon reflexes and somatosensory cerebral responses in man. Proc. Symp. Electronics in Medicine 1968; vol. 3: 15, Ljubljana
- Tyberghein J., Forrez G. Cortical audiometry in normal hearing subjects. Acta oto-laryng., Stockh. 1969; 67: 24–32
- Uttal W.R., Cook L. Systematics of the evoked somatosensory cortical potential: a psychophysiological-electrophysiological comparison. Ann. N.Y. Acad. Sci. 1964; 112: 60–80
- Walter G.W. Retrospective summary of definitive tests for hearing in young children. Acta oto-laryng., Stockh. 1965; 162–172, Suppl. 206