References
- House W F, Urban J C. Long term results of electrode implantation and electrical stimulation of the cochlea in man. Ann Otol Rhinol Laryngol 1973; 82: 504–510
- Burian K, Hochmair E S, Hochmair-Desoyer I J, Lessel M R. Designing of and experience with multichannel cochlear implants. Acta Otolaryngol (Stockh) 1979; 87: 190–195
- Eddington D K. Speech discrimination in deaf subjects with cochlear implants. J Acoust Soc Am 1980; 68: 885–891
- Michelson R P, Schindler R A. Multichannel cochlear implant: Preliminary results in man. Laryngoscope 1981; 91: 38–41
- Tong Y C, Clark G M, Seligman P M, Patrick J F. Speech processing for a multiple-electrode cochlear implant hearing prosthesis. J Acoust Soc Am 1980; 68: 1897–1899
- Patrick J F, Clark G M. The Nucleus 22-Channel Cochlear Implant System. Ear Hear 1991; l2(suppl to No 4)3–S-9S
- Tong Y C, Lim H H, Clark G M. Synthetic vowel studies on cochlear implant patients. J Acoust Soc Am 1988; 84: 876–887
- McKay C, McDermott H J, Vandali A, Clark G M. Preliminary results with a six spectral maxima sound processor for the University of Melbourne/Nucleus multiple-electrode cochlear implant. J Otolaryng Soc Austr 1991; 6: 354–359
- Dillier N, Lai W K, Bogli H. A high spectral transmission coding strategy for a multi-electrode cochlear implant. Advances in Cochlear Implants. Proc 3rd Int Cochlear Implant Conf, Innsbruck, 1994, 152–157
- Dillier N, Bogli H, Spillmann T. Speech encoding strategies for mul-tielectrode cochlear implants. A digital signal processor approach. Prog Brain Res 1993; 97: 301–311
- Wilson B S, Finley C C, Lawson D T, Wolford R D, Zerbi M. Design and evaluation of a continuous interleaved sampling (CIS) processing strategy for multichannel cochlear implants. J Rehabil Res Dev 1993; 30: 110–116
- Schíndler RA, Kessler D K, Hagger-ty H S. Clarion cochlear implant: Phase I investigational results (corrected; erratum to be published). Am J Otol 1993; 14: 263–272
- Zierhofer C, Peter O, Brill S. A multichannel cochlear implant system for high-rate pulsatile stimulation strategies. Advances in Cochlear Implants. Proc 3rd Int Cochlear Implant Conf, Innsbruck, 1994, 204–207
- Patrick J F, Seligman P M, Money D K, Kuzma J A. Engineering;. Cochlear Prostheses., G M Clark, Y T Tong, JF Patrick. Churchill Livingstone, Edinburgh 1990; 99–124
- McDermott H J, McKay C, Vandali A E. A new portable sound processor for the University of Melbourne/ Nucleus Limited multielectrode cochlear implant. J Acoust Soc Am 1992; 91: 3367–3371
- Skinner M W, Clark G M, Whitford L A. Evaluation of a new spectral peak coding strategy for the Nucleus 22 channel cochlear implant system. Am J Otol 1994; 15(suppl)15–27
- Dillier N, Battmer R D, Ddring W H, Miiller-Deile J. Multicentric field evaluation of a new spectral peak coding strategy with native German speaking cochlear implant users (abstract). Second Eur Symp on Paediatric Cochlear Implantation 1994, La Grande Motte, May 26–28,1994
- Dillier N, Battmer R D, Doring W H, Miiller-Deile J. Multicentric field evaluation of a spectral peak (SPEAK) cochlear implant speech coding strategy. Proc 5th Int Symp on Cochlear Implants. Surgical Workshop and 1st Int Auditory Brainstem Satellite Symp, Freiburg, June 24–26, 1994, in press
- Keller F. Verschiedene Aussprachen des Sprachverstandnistests nach DIN 45621 (Freiburger Test). Bio-med Tech (Berlin) 1977; 22: 292–298
- Hochmaier-Desoyer I J, Hochmair E S, Fischer R E, Burian K. Cochlear prostheses in use: Recent speech comprehension results. Arch Oto-rhinolaryngol 1980; 229: 81–98
- Wesselkamp M, Kliem K, Kollmei-er B. Erstellung eines optimierten Satztests in deutscher Sprache;. Moderne Verfah-ren der Sprachaudiometrie., B Kollmaier. Median-Verlag von Killisch-Horn, Heidelberg 1992; 330–343
- Miiller-Deile J. Logopadische Be-merkungen zum Satztest 1994, unpubl
- Niemeyer W. Sprachaudiometrie mit Satzen. I. Grundlagen und Testmaterial einer Diagnostik des Gesamtsprachverstandnisses. HNO 1967; 15: 335–343
- Thornton A RD, Raffin M JM. Speech-discrimination scores modeled as a binomial variable. J Speech Hear Res 1978; 21: 507–518
- Norusis MJ. SPSS for Windows Professional Statistics Release. SPSS Inc., Chicago 1992; 5
- Ni D, Seldon H L, Shepherd R K, Clark G M. Effect of chronic electrical stimulation on cochlear nucleus neuron size in normal hearing kittens (review). Acta Otolaryngol (Stockh) 1993; 113: 489–497