References
- Bailey R. R., Rogers T. G.H., Tail J. J. Measurement of glomerular filtration rate using a single injection of 51cr-edetic acid. Aust. NZ. J. Med 1970; 3: 255
- Bröchner-Mortensen J. A simple method for the determination of glomerular filtration rate. Scand. J. clin. Lab. Invest 1972; 30: 271
- Bröchner-Mortensen J. The glomerular filtration rate during moderate hyperglycemia in normal man. Acta med. Scand 1973; 194: 31
- Bröchner-Mortensen J. Routine methods and their reliability for assessment of glomerular filtration rate in adults. Dan. med. Bull 1978; 25: 181
- Bröchner-Mortensen J., Rödbro P. Comparison between total and renal plasma clearance of [51Cr]EDTA. Scand. J. clin. Lab. Invest 1976; 36: 247
- Chantler C., Garnett E. S., Parsons V., Veall N. Glomerular filtration rate measurement in man by the single injection method using 51Cr-EDTA. Clin. Sci. molec. Med 1969; 37: 169
- Fisher M., Veall N. Glomerular filtration rate estimation based on a single blood sample. Br. med. J 1975; ii: 542
- Furlani C., Morpurgo G., Sartori G. Absorption-spektren der Komplexe des dreiwertigen Chroms mit Äthylendiamintetraessigsäure. Z. anorg. allg. Chem 1960; 303: 1
- Garnett E. S., Parsons V., Veall N. Measurement of glomerular filtration-rate in man using a 51Cr/ edetic-acid complex. Lancet 1967; i: 818
- Hagstam K. E., Nordenfelt I., Svensson L., Svensson S. E. Comparison of different methods for determination of glomerular filtration rate in renal disease. Scand. J. clin. Lab. Invest 1974; 34: 31
- Hamm R. E. Complex ions of chromium. IV. The ethylenediaminetetraacetic acid complex with chromium(III). J. Am. chem. Soc 1953; 75: 5670
- Heath D. A., Knapp M. S., Walker W. H.C. Comparison between inulin and 51Cr-labelled edetic acid for the measurement of glomerular filtration rate. Lancet 1968; ii: 1110
- Knapp M. S., Walker W. H.C. Glomerular filtration rate. Br. med. J 1967; ii: 836, Letter
- Pecsok R. L., Shields L. D., Schaefer W. P. Complexes of chromium (II) and (III) with ethylenediaminetetraacetic acid. Inorg. Cheni 1964; 3: 114
- Stacy B. D., Thorburn G. D. Chromium-51 ethylenediaminetetraacetate for estimation of glomerular filtration rate. Science 1966; 152: 1076
- Stamp T. C.B., Stacey T. E., Rose G. A. Comparison of glomerular filtration rate measurements using inulin, 51CrEDTA, and a phosphate infusion technique. Clinica Chim. Acta 1970; 30: 351
- Venkatachalam M. A., Rennke H. G. The structural and molecular basis of glomerular filtration. Circulation Res 1978; 43: 337