8
Views
12
CrossRef citations to date
0
Altmetric
Original Article

Polarographic pO2 sensors with heparinized membranes for in vitro and continuous in vivo registration

, , &
Pages 557-563 | Received 15 Dec 1980, Accepted 10 Feb 1981, Published online: 08 Jul 2009

References

  • Asmussen E., Nielsen M. The disappearance of oxygen from shed blood at body temperature. Scand. J. clin. Lab. Invest 1961; 13: 297
  • Blume P. Blood gas measurements. Am J. clin. Path 1978; 70: 440
  • Brown E. G., McDonnel F. E. Oxygen saturation (SO2) and tension (PO2) continuously measured by one catheter. Pediat. Res 1980; 14: 593
  • Clark L. C. Monitoring and control of blood and tissue oxygen tensions. Trans. Am. Soc. Art. Int. Organs 1956; 2: 41
  • Eberhard P., Fehlmann W., Mindt W. An electrochemical sensor for continuous intravascular oxygen monitoring. Biotelemetry Patient Monitg 1979; 6: 16
  • Eriksson J. C., Berger G., Hultquist G., Larsson R., Olsson P., Lagergren H. Auger elecrron spectroscopy studies of glutardialdehyde-stabilized heparin hexadecylamine hydrochloride films. J. Colloid. Interface Sci 1979; 12: 142
  • Huch A., Huch R., Arner B., Rooth G. Continuous transcutaneous oxygen tension measured with a heated electrode. Scand. J. clin. Lab. Invest 1973; 31: 269
  • Lagergren H., Olsson P., Swedenborg J. Inhibited platelet adhesion: A non-thrombogenic characteristic of a heparin-coated surface. Surgery 1974; 75: 643
  • Larsson R., Eriksson J.-C., Lagergren H., Olsson P. Platelet and plasma coagulation compatibility of heparinized and sulphated surfaces. Thromb. Res 1979; 15: 157
  • Larsson R. L., Hjelte M.-B., Eriksson J. C., Lagergren H. R., Olsson P. The stability of glutardialdehyde-stabilized 35S-heparinized surfaces in contact with blood. Thrombos. Haemastas 1977; 31: 262
  • Larsson R., Olsson P., Lindahl U. Inhibition of thrombin and surfaces coated with immobilized heparin and heparin-like polysaccharides: a crucial non-thrombogenic principle. Thromb. Res 1980; 19: 43
  • Larsson R., Rosengren Å., Olsson P. Determination of platelet adhesion to polyethylene and heparinized surfaces with the aid of bioluminescence and 51Chromium labelled platelets. Thromb. Res 1977; 11: 517
  • Lenfant C., Aucutt C. Oxygen uptake and change of carbon dioxide tension in human blood stored at 37°C. J. appl. Pliysiol 1965; 20: 503
  • Lesouef P. N., Morgan A. K., Soutter L. P., Reynolds E. O., Parker D. Continuous comparison of transcutaneous and arterial oxygen tension in newborn infants with respiratory illnesses. Acta anaesthesiol. scand 1978; 68: 91
  • Malmgren R., Olsson P., Tornling G. Uptake and release of serotonin in adhering platelets. Relationship to time and effect of acetylsalicylic acid. Thromb. Res 1979; 15: 803
  • Naas R., Traahall. Reimplantation of isolated skin flaps in dogs with circulation maintained through artificial heparinized shunts. Scand. J. Plast. Reconstr. Surg 1977; 11: 23
  • Poolitzer M. J., Soutter L. P., Osmund E., Reynolds R. Continuous monitoring of arterial oxygen tension in infants: Four years of experience with an intravascular oxygen electrode. Pediatrics 1980; 66: 31

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.