15
Views
13
CrossRef citations to date
0
Altmetric
Original Article

Anticoagulant-induced preanalytical errors in ionized calcium determination on blood

, , , &
Pages 647-651 | Received 27 Oct 1988, Accepted 06 Apr 1989, Published online: 08 Jul 2009

References

  • Sachs C, Thode J (1986) Preanalytical errors in ionised calcium determination in blood: a review for a subsequent recommendation for sampling. Methodology and clinical applications of ion selective electrodes. Proceedings of the Fourth Meeting of the EWGISE, Helsinki, June, 1985, A HJ Maas, F BJ Boink, N EL Saris, R Sprokholt, P D Wimberley. Radiometer (Private Press), Copenhagen, 7: 259–70
  • Drop L J, Laver M B. Low plasma ionised calcium and response to calcium therapy in critically ill man. Anesthesiology 1975; 43: 300–6
  • Drop L J, Tochka L N, Misiano D R. Comparative evaluation of two calcium ion-selective electrode systems and their utility for monitoring steady-state changes in ionized calcium. Clin Chem 1982; 28: 129–33
  • Vacutainer Serum Separator (SST) Tubes. Method Instruction. Becton-Dickinson, Rutherford, NJ 1984
  • Toffaletti J, Blosser N, Kirvan K. Effects of storage temperature and time before centrifugation on ionized calcium in blood collected in plain Vacutainer Tubes and silicon-separator (SST) tubes. Clin Chem 1984; 30: 553–6
  • Larson L, Öhman S. Effect of silicon-separator tubes and storage time on ionized calcium in serum. Clin Chem 1985; 31: 169–70
  • Sigaard-Anderson O, Thode J, Wandrup J. The concentration of free calcium ions in the blood plasma, ‘ionized calcium’. Proceedings of the Seventh Meeting of the IFCC Expert Panel on pH and Blood Gases, O Siggaard-Andersen. Radiometer, (Private Press), Copenhagen 1981; 1 vol.: 163–9
  • Urban P, Buchmann B, Scheidegger D. Facilitated determination of ionized calcium. Clin Chem 1985; 31: 264–6
  • Falch-Christiansen T. Heparin and blood sampling for pH, blood gases and direct potentiomet-ric electrolyte analysis. Radiometer (Private Press), Copenhagen 1986; Vol. 1
  • Sachs C, Rabouine P, Kindermans C, Sage C (1987) Preanalytical dilution errors in ionized calcium determination on plasma and whole blood. Methodology and clinical applications of ion selective electrodes. Proceedings of the Seventh Meeting of EWGISE, Graz, Oct., 1986, A HJ Maas, B Buckley, H Marsoner, N E Saris, R Sprokholt. Radiometer (Private Press), Copenhagen, 8: 117–23
  • Sachs C, Bourdeau A, Balsan S. Determination du calcium ionisé dans le sérum avec une électrode spécifique à membrane liquide. Ann Biol Clin 1969; 27: 487–509
  • Bourdeau A M. Contribution à l'étude du dosage du calcium ionisé dans le sang par une électrode à membrane liquide. Université René Descartes, Paris 1972, PhD. (Pharmacy)
  • Moore E W. Ionized calcium in normal serum, ultrafiltrates and whole blood determined by ion-exchange electrodes. J Clin Invest 1970; 49: 318–34
  • Sachs C, Rabouine P, Chaneac M, Kindermans Dechaux C. M (1989) Limits of clinically acceptable preanalytical ‘calcium dilution’ errors in ionized calcium measurements on plasma and whole blood anticoagulated with dry ‘balanced’ sodium heparinate. Methodology and Clinical Applications of ion-selective electrodes. Proceedings of the Tenth Meeting of EGWISE, StresaItaly, Sept., 1988, A HJ Maas, B Buckley, A Manzoni, et al. Radiometer (Private Press), 10: 85–8

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.