Internal membranes and laminates for adaptation of amperometric enzyme electrodes to direct biofluid analysis

, , , &
Pages 53-60 | Published online: 08 Jul 2009

References

  • Turner A PF, Karube I, Wilson G S. “Biosensor: Fundamentals and Applications”. Oxford Science Publication, New York 1987
  • Guilbaut G G. Enzyme electrode probes. Methods in Enzymology 1988; 137: 14–29
  • Mc Donnell M B, Vadgama P M. Membranes: Separation principles and sensing. Selective Electrode Rev 1989; 11: 17–67
  • Mullen W H, Keedy F H, Churchouse S J, Vadgama P M. Glucose enzyme electrode with extended linearity; application to undiluted blood measurements. Anal Chim Acta 1986; 183: 59–66
  • Vadgama P. Diffusion limited enzyme electrodes. Analytical Uses of Immobilised Biological Compounds for Detection, Medical and Industrial Uses, G G Guilbaut, M Mascini. D. Reidel Publishing Co., Dordrecht 1988; 359–77
  • Schichiri M, Kawamori R, Hakui N, Abe H. Wearable artificial endocrine pancreas with needle-type sensor. The Lancet 1982; ii: 1129–31
  • Churchouse S J, Battersby C M, Mullen W H, Vadgama P M. Needle enzyme electrodes for biological studies. Biosensors 1986; 2: 325–42
  • Tuschada T, Yoda K. Multi-enzyme membrane electrodes for determination of creatinine and creatine in serum. Clin Chem 1983; 29: 837–41
  • Vadgama P, Spoors J, Tang L X, Battersby C. The needle glucose electrode: In-vitro performance and optimisation for implantation. Biomed Biochim Acta 1989; 48: 935–42
  • Crump P W, Ghosh S, Vadgama P. Blood testing of a polyether-urethane as a diffusion limiting and potentially haemocompatible external membrane for enzyme electrode biosensors. Testing of standard biomaterials. Concerted action on replacement of body parts and functions, Haemo-compatibility. Medical research programme of the European communities. 1992, Gentofte, Copenhagen January 31st - February 1st.(in press)
  • Gorton L, Karan H I, Hale P D, Inagaki T, Okamoto Y, Skothein T A. A glucose electrode based on carbon paste chemically modified with a ferrocene-containing siloxane polymer and glu-cose-oxidase, coated with a poiy(ester-suiphonic acid) cation-exchanger. Anal Chim Acta 1990; 223: 23–30
  • Meares P. “Membrane separation processes”. Elsevier, Amsterdam 1976
  • Cass A EG, Davis G, Francis G D, Hill H AO, Aston W J, Higgens I J, Plotkin E V, Scott L DL, Turner A PF. Ferrocene-mediated enzyme electrode for amperometric determination of glucose. Anal Chem 1984; 56: 667–71
  • Cardosi M F, Turner A PF. The realisation of electron transfer from biological molecules to electrodes. Biosensors: Fundamentals and Applications. Turner APF, I Karube, G S Wilson. Oxford University Press, Oxford 1987; 257–75
  • Francis G, Hill H AO, Higgens I J, Aston W J, Plotkin E V, Scott L DL, Turner A PF. Ferrocene mediated enzyme electrode for amperometric determination of glucose. Anal Chem 1984; 56: 667–71
  • Vroman L. What factors determine thrombo-genicity. Bull. N.Y. Acad Sci 1972; 48: 302–10
  • Vadgama P. Biosensors: Adaptation for practical use. Sensors and Actuators 1990; 8: 1–7

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.