References
- Assman G, Brinkers H, Schulte H, Carstensen C A. Comparison of the reflectance method (Reflotron reflectance photometer) with the absorbance method (automatic analyzers) for the determination of cholesterol. J Clin Chem Clin Biochem 1989; 27: 961–6
- Bachorik P S., Bradford R H., Cole T, et al. Accuracy and precision of analyses for total cholesterol as measured with the Reflotron cholesterol method. Clin Chem 1989; 35: 1734–9
- Selmer R, Foss O P., Lund-Larsen P G. Reliability of the Reflotron in the determination of cholesterol. Scand J Clin Lab Invest 1990; 50: 261–72
- Bachorik P S., Rock R, Treciak E, Becker D, Sigmund W. Cholesterol Screening: Comparative evaluation of on-site and laboratory-based measurements. Clin Chem 1990; 36: 255–60
- Miller G M., McKenney J M., Conner M R., Chinchilli V M. Total error assessment of five methods for cholesterol screening. Clin Chem 1993; 39(2)297–304
- Statland B E. A review of the analytic performance of the Reflotron system for testing. Clin Ther 1990; 12: 281–6
- Iosefsohn M, Hicks J M. An evaluation of the Boehringer Mannheim Reflotron in a pediatric setting. Clin Chem 1988; 34: 1172, abstr
- Jenner D A., Dunbar D, Vandongen R, Beilin L J. Reflotron cholesterol measurements in 1112 Australian children aged 10–12 years. Med J Austr 1991; 155: 222–5
- Kovanen H, Jokinen E, Myyrinmaa A, et al. Intervention trial in children for early prevention of atherosclerosis-preliminary results. Ped Res 1992; 31: 124A, abstr.
- Siedel J, Schlunberger H, Klose S, Ziegenhorn J, Wahlefeld A W. Improved reagent for the enzymatic determination of serum cholesterol. J Clin Chem Clin Biochem 1981; 19: 838–9
- Bland J M., Altman D G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; i: 307–10
- Boerma G JM, Gelderland J, van Gorp I, Lejnse B. Use of the Reflotron system for cholesterol assay in capillary blood, venous blood and serum-evaluation of accuracy and lot-to-lot reagent comparability. Clin Chem 1988; 34: 2117–9
- Koch T R., Mehta U, Lee H, et al. Bias and precision of cholesterol analyses by physician's office analyzers. Clin Chem 1987; 33: 2262–7
- Kupke I R., Zeygner S, Gottschalk A, Kather B. Difference in lipid and lipoprotein concentrations of capillary and venous blood samples. Clin Chim Acta 1979; 97: 279–83
- National Cholesterol Education Program (NCEP). Highlights of the report of the expert panel on blood cholesterol levels in children and adolescents. Pediatrics 1991; 89: 495–501