519
Views
11
CrossRef citations to date
0
Altmetric
Research Article

Fast conductivity imaging in magnetic resonance electrical impedance tomography (MREIT) for RF ablation monitoring

, , , , , & show all
Pages 447-455 | Received 14 Apr 2014, Accepted 13 Sep 2014, Published online: 20 Oct 2014

References

  • Ni Y, Mulier S, Miao Y, Michel L, Marchal G. A review of the general aspects of radiofrequency ablation. Abdom Imaging 2005;30:381–400
  • Dodd GD, Soulen MC, Kane RA, Livraghi T, Lees WR, Yamashita Y, et al. Minimally invasive treatment of malignant hepatic tumors: At the threshold of a major breakthrough. Radiographics 2000;20:9–27
  • Lubner MG, Brace CL, Hinshaw JL, Lee FT. Microwave tumor ablation: Mechanism of action, clinical results, and devices. J Vasc Interv Radiol 2010;21:S192–203
  • Abdalla EK, Vauthey JN, Ellis LM, Ellis V, Pollock R, Broglio KR, et al. Recurrence and outcomes following hepatic resection, radiofrequency ablation, and combined resection/ablation for colorectal liver metastases. Ann Surg 2004;239:818–27
  • Haemmerich D, Laeseke PF. Thermal tumour ablation: Devices, clinical applications and future directions. Int J Hyperthemia 2005;21:755–60
  • Ahmed M, Liu Z, Afzal KS, Weeks D, Lobo SM, Kruskal JB, et al. Radiofrequency ablation: Effect of surrounding tissue composition on coagulation necrosis in a canine tumor model. Radiology 2004;230:761–7
  • Chauhan M, Jeong WC, Kim HJ, Kwon OI, Woo EJ. Radiofrequency ablation lesion detection using MR-based electrical conductivity imaging: A feasibility study of ex vivo liver experiments. Int J Hyperthermia 2013;29:643–52
  • Cosman ERJ, Cosman ERS. Electric and thermal field effects in tissue around radiofrequency electrodes. Pain Med 2005;6:405–24
  • Goldberg SN, Grassi CJ, Cardella JF, Charboneau JW, Dodd GD III, Dupuy DE, et al. Image-guided tumor ablation: Standardization of terminology and reporting criteria. J Vasc Interv Radiol 2009;7:S377–90
  • Dalong L, Ebbini ES. Real-time 2-D temperature imaging using ultrasound. IEEE Trans Biomed Eng 2010;57:12–16
  • Carey RI, Leveillee RJ. First prize: Direct real-time temperature monitoring for laparoscopic and CT-guided radiofrequency ablation of renal tumors between 3 and 5 cm. J Endourol 2007;21:807–13
  • Quesson B, de Zwart JA, Moonen CT. Magnetic resonance temperature imaging for guidance of thermotherapy. J Magn Reson Imaging 2000;12:525–33
  • Lewin JS, Connell CF, Duerk JL, Chung YC, Clampitt ME, Spisak J, et al. Interactive MRI-guided radiofrequency interstitial thermal ablation of abdominal tumors: Clinical trial for evaluation of safety and feasibility. J Magn Reson Imaging 1998;8:40–7
  • Hindman JC. Proton resonance shift of water in the gas and liquid state. J Chem Phys 1966;44:4582–92
  • Ishihara Y, Calderon A, Watanabe H, Okamoto K, Suzuki Y, Kuroda K, et al. Precise and fast temperature mapping using water proton chemical shift. Magn Reson Med 1995;34:814–23
  • Rempp H, Martirosian P, Boss A, Clasen S, Kickhefel A, Kraiger M, et al. MR temperature monitoring applying the proton resonance frequency method in liver and kidney at 0.2 and 1.5 T: Segment-specific attainable precision and breathing influence. Magn Reson Mater Phys 2008;21:333–43
  • Delannoy J, Chen CN, Turner R, Levin RL, Le Bihan D. Noninvasive temperature imaging using diffusion MRI. Magn Reson Med 1991;19:333–9
  • Peng HH, Huang TY, Tseng WY, Lin EL, Chung HW, Wu CC, et al. Simultaneous temperature and magnetization transfer (MT) monitoring during high-intensity focused ultrasound (HIFU) treatment: Preliminary investigation on ex vivo porcine muscle. J Magn Reson Imaging 2009;30:596–605
  • Rieke V, Pauly KB. MR thermometry. J Magn Reson Imaging 2008;27:376–90
  • Mori K, Fukuda K, Asaoka H, Ueda T, Kunimatsu A, Okamoto Y, et al. Radiofrequency ablation of the liver: Determination of ablative margin at MR imaging with impaired clearance of ferucarbotran – Feasibility study. Radiology 2009;251:557–65
  • Limanond P, Zimmerman P, Raman SS, Kadell BM, Lu DS. Interpretation of CT and MRI after radiofrequency ablation of hepatic malignancies. Am J Roentgenol 2003;181:1635–40
  • Geddes LA, Baker LE. The specific resistance of biological material: A compendium of data for the biomedical engineer and physiologist. Med Biol Eng 1967;5:271–93
  • Grimnes S, Martinsen OG. Bioimpedance and Bioelectricity Basics. London: Academic Press, 2011
  • Pop M, Molckovsky A, Chin L, Kolios MC, Jewett MA, Sherar MD. Changes in dielectric properties at 460 kHz of kidney and fat during heating: Importance for radio-frequency thermal therapy. Phys Med Biol 2003;48:2509–25
  • Haemmerich D, Schutt DJ, Wright AS, Webster JG, Mahvi DM. Electrical conductivity measurement of excised human metastatic liver tumours before and after thermal ablation. Physiol Meas 2009;30:459–66
  • Goldberg SN, Gazelle GS, Dawson SL, Rittman WJ, Mueller PR, Rosenthal DI. Tissue ablation with radiofrequency: Effect of probe size, gauge, duration, and temperature on lesion volume. Acad Radiol 1995;2:399–404
  • Woo EJ, Seo JK. Magnetic resonance electrical impedance tomography (MREIT) for high-resolution conductivity imaging. Physiol Meas 2008;29:R1–26
  • Seo JK, Woo EJ. Magnetic resonance electrical impedance tomography (MREIT). SIAM Review 2011;53:40–68
  • Seo JK, Woo EJ. Electrical tissue property imaging at low frequency using MREIT. IEEE Trans Biomed Eng 2014;61:1390–9
  • Joy MLG, Scott GC, Henkelman RM. In vivo detection of applied electric currents by magnetic resonance imaging. Magn Reson Imag 1989;7:89–94
  • Scott GC, Joy MLG, Armstrong RL, Henkelman RM. Measurement of nonuniform current density by magnetic resonance. IEEE Trans Med Imag 1991;10:362–74
  • Seo JK, Yoon JR, Woo EJ, Kwon O. Reconstruction of conductivity and current density images using only one component of magnetic field measurements. IEEE Trans Biomed Eng 2003;50:1121–4
  • Oh SH, Lee BI, Woo EJ, Lee SY, Cho MH, Kwon O, et al. Conductivity and current density image reconstruction using harmonic Bz algorithm in magnetic resonance electrical impedance tomography. Phys Med Biol 2003;48:3101–16
  • Ider YZ, Birgul O. Use of the magnetic field generated by the internal distribution of injected currents for electrical impedance tomography (MR-EIT). Elektrik 1998;6:215–25
  • Joy MLG. MR current density and conductivity imaging: The state of the art. Proc 26th Ann Int Conf IEEE EMBS, San Francisco, CA, USA 2004:5315–19
  • Hamamura M, Muftuler L, Birgul O, Nalcioglu O. Measurement of ion diffusion using magnetic resonance electrical impedance tomography. Phys Med Biol 2006;51:2753–62
  • Park C, Lee BI, Kwon O, Woo EJ. Measurement of induced magnetic flux density using injection current nonlinear encoding (ICNE) in MREIT. Physiol Meas 2006;28:117–27
  • Haacke EM, Petropoulos LS, Nilges EW, Wu DH. Extraction of conductivity and permittivity using magnetic resonance imaging. Phys Med Biol 1991;36:723–33
  • Katscher U, Voigt T, Findeklee C, Vernickel P, Nehrke K, Dössel O. Determination of electrical conductivity and local SAR via B1 mapping. IEEE Trans Med Imag 2009;28:1365–74
  • Webster JG. Electrical Impedance Tomography. Bristol: Adam Hilger, 1990
  • Holder D. Electrical Impedance Tomography: Methods, History and Applications. Bristol: IOP, 2005
  • Oh TI, Kim HJ, Jeong WC, Chauhan M, Kwon OI, Woo EJ. Detection of temperature distribution via recovering electrical conductivity in MREIT. Phys Med Biol 2013;58:2697–711
  • Scott GC, Joy MLG, Armstrong RL, Hankelman RM. Sensitivity of magnetic resonance current density imaging. J Magn Reson 1992;97:235–54
  • Sadleir R, Grant S, Zhang SU, Lee BI, Pyo HC, Oh SH, et al. Noise analysis in MREIT at 3 and 11 Tesla field strength. Physiol Meas 2005;26:875–84
  • Minhas AS, Jeong WC, Kim YT, Han Y, Kim HJ, Woo EJ. Experimental performance evaluation of multi-echo ICNE pulse sequence in magnetic resonance electrical impedance tomography. Magn Reson Med 2011;66:957–65
  • Nam HS, Kwon OI. Optimization of multiply acquired magnetic flux density Bz using ICNE-Multiecho train in MREIT. Phys Med Biol 2010;55:2743–59
  • Kwon O, Woo EJ, Yoon JR, Seo JK. Magnetic resonance electrical impedance tomography (MREIT): simulation study of J-substitution algorithm. IEEE Trans Biomed Eng 2002;49:160–7
  • Kim YT, Yoo PJ, Oh TI, Woo EJ. Magnetic flux density measurement in magnetic resonance electrical impedance tomography using a low-noise current source. Meas Sci Technol 2011;22:1–9
  • Oh TI, Jeong WC, McEwan A, Park HM, Kim HJ, Kwon OI, et al. Feasibility of magnetic resonance electrical impedance tomography (MREIT) conductivity imaging to evaluate brain abscess lesion: In vivo canine model. J Magn Reson Imaging 2012;38:189–97
  • Senneville BD, Quesson B, Moonen CTW. Magnetic resonance temperature imaging. Int J Hyperthermia 2005;21:515–31
  • Terraz S, Cernicanu A, Lepetit-Coiffe M, Viallon M, Salomir R, Mentha G, et al. Radiofrequency ablation of small liver malignancies under magnetic resonance guidance: Progress in targeting and preliminary observations with temperature monitoring. Eur Radiol 2010;20:886–97
  • Kim HJ, Jeong WC, Sajib SZ, Kim MO, Kwon OI, Woo EJ, Kim DH. Simultaneous imaging of dual-frequency electrical conductivity using a combination of MREIT and MREPT. Magn Reson Med 2014;71:200–8
  • Kim Y, Rhim H, Cho OK, Koh BH, Kim Y. Intrahepatic recurrence after percutaneous radiofrequency ablation of hepatocellular carcinoma: Analysis of the pattern and risk factors. Eur J Radiol 2006;59:432–41

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.