The practical use of thermocouples for temperature measurement in clinical hyperthermia

, &
Pages 1-19 | Received 02 Sep 1985, Published online: 20 Aug 2012

References

  • ANDERSEN, J., BACH, BAUN, A., HARMARK, K., HEINZL, L., RASMARK, P., and OVERGAARD, J., 1984, A hyperthermia system using a new type of inductive applicator. IEEE Transactions. Biomedical Engineering, BME31,21�27.
  • BINI, M. G., IGNESTI, A., MILLANTO, L., OLMI, R., Rubino, N., and VANNI, R., 1984, The poly-acrylamide as a phantom material for electromagnetic hyperthermia studies. IEEE Transactions. Biomedical Engineering, BME31,317–322.
  • BLEANEY, B. I., and BLEANEY, B., 1965, Electricity and Magnetism (Oxford: Clarendon Press), pp. 103–109.
  • BOWMAN, R. R., 1976, A probe for measuring temperature in radiofrequency heated material. IEEE Transactions. Microwave Technology and Techniques, MTT24,43–45.
  • CETAS, T. C, 1975, Temperature measurement in microwave diathermy fields: principles and probes. Proceedings of the International Symposium on Cancer Therapy by Hyper�thermia and Radiation, Washington, D.C., edited by J. E. Robinson and M. J. Wizenberg (Baltimore: American College of Radiology Pr.), pp. 193–203.
  • CETAS, T. C, 1978, Thermometry in strong electromagnetic fields. The Physical Basis of Electromagnetic Interactions with Biological Systems, edited by L. S. Taylor and A. Y. Cheung (College Park, MD: University of Maryland), p. 261.
  • CETAS, T. C, 1981, Thermometry. Therapeutic Heat and Cold, 3rd edn, edited by J. F. Lehmann (Baltimore: Williams and Wilkins), pp. 35–69.
  • CETAS, T. C, and CONNOR, W. G., 1978, Thermometry considerations in localized hyperthermia. Medical Physics, 5, 79–91.
  • CETAS, T. C, 1985, Thermometry and thermal dosimetry. Hyperthermic Oncology 1984, Vol. 2 (London, Philadelphia: Taylor and Francis), pp. 91–112.
  • CETAS, T. C, CONNOR, W. G., and MANNING, M. R., 1980, Monitoring of tissue temperature during hyperthermia therapy. Annals of the New York Academy of Sciences, 335, 281–297.
  • CHAKRABORTY, D. P., and BREZOVICH, I. A., 1982, Error sources affecting thermocouple thermometry in RF electromagnetic fields. Journal of Microwave Power, 17, 17–28
  • CHRISTENSEN, D. A., 1977, A new non-perturbing temperature probe using semiconductor band edge shift. Journal of Bioengineering, 1, 541–545.
  • DICKINSON, R. J., 1985, Thermal conduction errors of manganin-constantan thermocouple arrays. Physics in Medicine and Biology, 30,445�453.
  • FESSENDEN, P., LEE, E. R., and SAMULSKI, T. V., 1984, Direct temperature measurement. Cancer Research, Suppl., 44,4799s–4804s.
  • FRY, W. J., and FRY, R. B., 1954 a, Determination of absolute sound levels and absorption coefficients by thermocouple probes�theory. Journal of the Acoustic Society of America,26,294–310.
  • FRY, W. J., and FRY, R. B., 1954 b, Determination of absolute sound levels and absorption coefficients by thermocouple probes�experiment. Journal of the Acoustic Society of America, 26, 311–317.
  • GAMMAMPILA, K., DUNSCOMBE, P. B., SOUTHCOTT, B. M., and STACEY, A. J., 1981, Thermo�couple thermometry in microwave fields. Clinical Physics and Physiological Measure�ment, 2, 285–292.
  • GIBBS, F. A., 1983, 'Thermal Mapping' in experimental cancer treatment with hyperthermia: description and use of a semi-automatic system. International Journal of Radiation, Oncology, Biology, Physics, 9,1057–1063.
  • Goss, S. A., COBB, J. W., and FRIZZELL, L. A., 1977, Effect of beam width and thermocouple size on the measurement of ultrasonic absorption using the thermocouple technique. IEEE Ultrasonics Symposium Proceedings, Catalogue No. 77 CHI264-1 SU, pp. 206–211.
  • GRIFFITHS, H., SMITH, C. W., and KERBY, J. J., 1985, A thermocouple system for continuous thermometry in radiofrequency hyperthermia. British Journal of Radiology, 58,169–170.
  • HAND, J. W., and DICKINSON, R. J., 1984, Linear thermocouple arrays for in vivo observation of ultrasonic hyperthermia. British Journal of Radiology, 57, 654.
  • HAND, J. W., 1985, Thermometry in hyperthermia. Hyperthermic Oncology 1984, Vol. 2, edited by J. Overgaard (London, Philadelphia: Taylor & Francis), pp. 299–308.
  • HARMARK, K., 1983, Design of multipoint thermometer. Strahlentherapie, 159, 373 (abstract).
  • HYNYNEN, K., MARTIN, C. J., WATMOUGH, D. J., and MALLARD, J. R., 1983, Errors in temperature measurement by thermocouple probes during ultrasound induced hyperthermia. British Journal of Radiology, 56,969–970.
  • JOINER, M. C, 1980, The effect on experimental tumours of hyperthermia in combination with cytotoxic drugs or gamma radiation with special reference to ultrasound as a method ofheating, Ph.D thesis, University of London, section 5.3.4.
  • JONES, C. H., and CARNOCHAN, P., 1985, Infra red thermography and liquid crystal plate thermography. Handbook of Techniques for Clinical Hyperthermia, edited by J. W. Handand J. R. James (Letchworth, Herts.: Research Studies Press) (in the press).
  • LARSEN, L. E., MOORE, R. A., and AKEVEDO, J., 1974, A microwave decoupled brain-temperature transducer. IEEE Transactions. Microwave Technology and Techniques, MTT22,438–444.
  • MARTIN, C. J., and LAW, A. N. R., 1983, Design of thermistor probes for measurement of ultrasound intensity. Ultrasonics, 21, 85–90.
  • MUNRO, P., HILL, R. P., and HUNT, J. W., 1982, The development of improved ultrasound heaters suitable for superficial tissue heating. Medical Physics, 9,888–897.
  • OVERGAARD, J. (editor), 1985, Hyperthermic Oncology 1984, Vols 1 and 2 (London, Philadelphia: Taylor & Francis).
  • SAMULSKI, T. V., LYONS, B. E., and BRITT, R. H., 1985, Temperature measurements in high thermal gradients: II Analysis of conduction effects. International Journal of Radiation, Oncology, Biology, Physics, 11, 963–971.
  • SINGH, B. S., and DYBBS, A., 1976, Error in temperature measurements due to conduction along the sensor leads. Journal of Heat Transfer, 98,491–495.
  • SZWARNOWSKI, S., SHEPPARD, R. J., GRANT, E. H., and BLEEHEN, N. M., 1980, A thermocouple for measuring temperature in biological material heated by microwaves at 2-45 GHz. British Journal of Radiology, 53, 711–715.
  • VOJNOVIC, B., and JOINER, M. C, 1985, A multiple RF heating system for experimental hyper�thermia in small animals. International Journal of Hyperthermia, 1,287–298.
  • WARREN, S. L., 1935, Preliminary study of the effect of artificial fever upon hopeless tumour cases. American Journal of Roentgenology, 33, 75–87.
  • WICKERSHEIM, K. A., and ALVERS, R. V., 1979, Recent advances in optical temperature measurements. Industrial Research and Development, 21, 82–89.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.