395
Views
14
CrossRef citations to date
0
Altmetric
Original Article

Radiation Quality Independent Liquid Ionization Chamber for Dosimetry of Electron Radiation from Medical Accelerators

Pages 37-48 | Received 20 Feb 1973, Published online: 08 Jul 2009

References

  • Berger M. J., Seltzer S. M. Tables of energy losses and ranges of electrons and positrons. NASA SP-3012, National Aeronautics and Space Administration, Washington, D.C. 1964
  • Berger M. J., Seltzer S. M. Additional stopping power and range tables for protons, mesons and electrons. NASA SP-3036, National Aeronautics and Space Administration, Washington, D.C. 1966
  • Berger M. J., Seltzer S. M. (a) Calculation of energy and charge deposition and of the electron flux in a water medium bombarded with 20 MeV electrons. High-energy radiation therapy dosimetry, J. S. Laughlin, 1969; 8, Ann. N.Y. Acad. Sci. 161
  • Berger M. J., Seltzer S. M. (b) Quality of radiation in a water medium irradiated with high-energy electron beams. Book of Abstracts. 1969; 127, 12th International Congress of Radiology, Tokyo
  • Blanc D., Mathieu J., Torres L. Relation entre les courbes caractéristiques des chambres d'ionisation remplies d'hexane liquide et l'ionisation spécifique du rayonnement incident, application possible à la mesure du facteur de qualité d'un rayonnement complexe. Nucl. Instr. Meth. 1963; 27: 353
  • Boag J. W. Ionization measurements at very high intensities. Brit. J. Radiol. 1950; 23: 601
  • Casanovas J., Patau J. P., Mathieu U. J., Blanc D. Comparaison entrel'ionisation produite dans le volume sensible d'une chambre d'ionisation à diélectrique liquide et l'énergie qui y est déposée, calculée par la méthode de Monte-Carlo, dam le cas d'irradiation par des électrons monocinétiques de 1.5 et 1.9 MeV. Third symposium on microdosimetry, StresaItaly, 1971; 571, EUR 4810 d-f-e
  • Charalambus S. The response of a liquid ionization chamber to gamma radiation and high-energy neutrons and protons. Nucl. Instr. Meth. 1967; 48: 181
  • Debye P. Reaction rates in ionic solutions. Trans. electrochem. Soc. 1942; 82: 265
  • Dutreix J., Dutreix A. Éude comparée d'une série de chambres d'ionisation dans des faisceaux d'électrons de 20 et 10 MeV. Biophysik 1966; 3: 249
  • Harder D. (1965) Berechnung der Energiedosis aus Ionisations-Messungen bei Sekundärelektronen-Gleichgewicht. Symposium on high-energy electrons, Montreaux. 1964, A. Zuppinger, G. Poretti. Springer Verlag, Berlin
  • Harder D. The effect of multiple electron scattering on the ionization in gas filled cavities. Biophysik 1968; 5: 157
  • Hettinger G., Pettersson C., Svensson H. Displacement effect of thimble chambers exposed to a photon or electron beam from a betatron. Acta radiol. Ther. Phys. Biol. 1967; 6: 61
  • HPA Report Series No. 4: A practical Guide to Electron Dosimetry. The Hospital Physicists Association, London 1971
  • ICRU Report 21. Radiation Dosimetry. Electrons with initial energies between 1 and 50 MeV. International Commission on Radiation Units and Measurements, Washington, D.C. 1972
  • Mathieu J. Thèse de Doctorat ès Sciences 313, 1968, Toulouse
  • Mathieu J., Blanc D., Casanovas J., Dutreix A., Wambersie A., Prignot M. Mesure de la répartition de la dose déposée en profondeur dans un fantôme de Plexiglas irradié par un faisceau d'électrons monocinétiques de 10, 15, 20 ou 30 MeV. Second symposium on microdosimetry, StresaItaly, 1969; 437, EUR 4452 d-f-e
  • NACP. Recommendations of the Nordic Association of Clinical Physics: Procedures in radiation therapy dosimetry with 5 to 50 MeV electrons and roentgen and gamma rays with maximum photon energies between 1 MeV and 50 MeV. Acta radiol. Ther. Phys. Biol. 1972; 11: 603
  • Onsager L. Initial recombination of ions. Phys. Rev. 1938; 54: 554
  • Pettersson C., Hettinger G. Dosimetry of high-energy electron radiation based on the ferrous sulphate dosimeter. Acta radiol. Ther. Phys. Biol. 1967; 6: 160
  • Schmidt W. F., Allen A. O. Yield of free ions in irradiated liquids; determination by clearing field. J. phys. Chem. 1968; 72: 3730
  • Svensson H. Influence of scattering foils, transmission monitors and collimating system on the absorbed dose distribution from 10 to 35 MeV electron radiation. Acta radiol. Ther. Phys. Biol. 1971; 10: 443
  • Svensson H., Pettersson C. Absorbed dose calibration of thimble chambers with high energy electrons at different phantom depth. Ark. Fysik 1967; 34: 377
  • Tewari P. H., Freeman G. R. Dependence of radiation induced conductance of liquid hydrocarbons on molecular structure. J. chem. Phys. 1968; 49: 4394
  • Thomson J. J. The roentgen rays. Nature (Lond.) 1895; 53: 377
  • Wickman G. Townsendkopplad jonkammarutrustning med automatisk kompensering och digital utläsning. (In Swedish.) Nord. Med. 1969; 82: 1264
  • Wickman G. Small gas-tight ionization chambers for absorbed dose control during radiation therapy. Acta radiol. 1972, Suppl. No. 313: 152

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.