References
- An K N, Ueba Y, Chao E Y, Cooney W P, Linscheid R L. Tendon excursion and moment arm of index finger muscles. J. Biomech 1983; 16: 419–425
- Bader K F, Sethi G, Curtin J W. Silicone pulleys and underlays in tendon surgery. Plast Reconstr Surg 1968; 41: 157–163
- Barton N J. Experimental study of optimum location of flexor tendon pulleys. Plast Reconstr Surg 1969; 43: 125–129
- Boyce B. Biologic and synthetic vascular prosthesis: Physical characteristics of expanded polytetrafluoroethylene grafts, J C Stanley. Grune & Stratton, Inc. 1982; 553–561
- Brand P W, Cranor K C, Ellis J C. Tendon and pulleys at the metacarpophalangeal joint of a finger. J Bone Joint Surg 1975; 57-A: 779–784
- Bunnell S. Repair of tendons in the fingers and description of two new instruments. Surg Gynecol Obstet 1918; 26: 103–110
- Cheng J CY, Hsu S YC, Chong Y W, Leung P C. Use of bioprosthetic tendon in digital pulley reconstruction—an experimental study. J Hand Surg 1986; 11–B: 225–230
- Cleveland M. Restoration of the digital portion of a flexor tendon and sheath in the hand. J Bone Joint Surg 1933; 15: 762–765
- Doyle J R, Blythe W. The finger flexor tendon sheath and pulleys: anatomy and reconstruction. AAOS symposium in tendon surgery in the hand. The CV Mosby Co, St Louis 1975; 81–87
- Doyle JR. Tendon surgery in the hand: Dynamics of the flexor tendon pulley system, J M Hunter, L H Schneider, E J Mackin. The CV Mosby Co, St Louis 1987; 20–23
- Dunlap J, McCarthy J A, Manske P R. Flexo tendon pulley reconstructions—a histological and ultrastructural study in non-human primates. J Hand Surg 1989; 14-B: 273–277
- Dunlap J, McCarthy J A, Joyce M E, Manske P R. Biomechanical and histologic evaluations of reconstructions in nonhuman primates. J Hand Surg 1990; 15A: 57–63
- Hunter J M, Cook J F, Ochiai N, Konikoff J J, Merklin R J, Mackin G A. The pulley system. J Hand Surg 1980; 5: 283
- Hunter J M, Cock J F. Difficult problems in hand surgery: The pulley system: rationale for reconstruction, J W Strickland, J B Steichen. CV Mosby Co, St Louis 1982; 94–102
- Hunter J M. Kaplan's functional and surgical anatomy of the hand: Anatomy of flexor tendons-pulley, vincular, synovia, and vascular structures, M Spencer. JB Lippincott Co, Philadelphia 1984; 65–92
- Kain C C, Manske P R, Reinsel T E, Rouse A M, Peterson W W. Reconstruction of the digital pulley in the monkey using biologic and nonbiologic materials. J Orthop Res 1988; 6: 871–877
- Karev A. The “belt loop” technique for the reconstruction of pulleys in the first stage of flex tendon grafting. J Hand Surg 1984; 9A: 923–924
- Karev A, Stahl S, Taran A. The mechanical efficiency of the pulley system in normal digits compared with a reconstructed system using the “belt loop” technique. J Hand Surg 1987; 12A: 596–600
- Kleinert H E, Bennett J B. Digital pulley reconstruction employing the always present rim of the previous pulley. J Hand Surg 1978; 3: 297–298
- Lister G D. Reconstruction of pulleys employing extensor retinaculum. J Hand Surg 1979; 4: 461–464
- Manske P R, Lesker P A. Strength of human pulleys. Hand 1977; 9: 147–152
- Manske P R, Lesker P A. Palmar aponeurosis pulley. J Hand Surg 1983; 8(3)259–263
- Neel H B, III. Implants of Gore-Tex. Arch Otolaryngol 1983; 109: 427–433
- Peterson W W, Manske P R, Lesker P A, Kain C C, Schaefer R K. Development of a synthetic replacement for the flexor tendon pulleys—An experimental study. J Hand Surg 1986; 11A: 403–409
- Peterson W W, Manske P R, Bollinger B A, Lesker P A, McCarthy J A. Effect of pulley excision on flexor tendon biomechanics. J Orthop Res 1986; 4: 96–101
- Solonen K A, Hoyer P. Positioning of the pulley mechanism when reconstructing deep flexor tendons of fingers. Acta Orthop Scand 1967; 38: 321–328
- Widstrom C J, Johnson G, Doyle J R, Manske P R, Inhofe P. A mechanical study of six digital pulley reconstruction techniques: Part 1. Mechanical effectiveness. J Hand Surg 1989; 14A: 821–825
- Widstrom C J, Doyle J R, Johnson G, Manske P R, McGee R. A mechanical study of six digital pulley reconstruction techniques: Part 2. Strength of individual reconstructions. J Hand Surg 1989; 14A: 826–829
- Wray R C, Weeks P M. Reconstruction of digital pulleys. Plast Reconstr Surg 1974; 53: 534–536