Inter-electrode tissue resistance is not affected by tissue oedema when electrically stimulating the lower limb of sepsis patients

, &
Pages 227-231 | Received 19 Dec 2013, Accepted 11 Mar 2014, Published online: 23 Apr 2014

References

  • American College of Chest Physicians, 1992, American College of Chest Physicians/Society of Critical Care Medicine Consensus Conference: definitions for sepsis and organ failure and guidelines for the use of innovative therapies in sepsis. Critical Care Medicine, 20, 864–874
  • Ginz, H.F., Bandschapp, O., Urwyler, A., Girard, T., and Iaizzo, P.A., 2010, Tissue oedema is not associated with skeletal muscle weakness in septic patients. Acta Anaesthesiologica Scandinavica, 54, 904
  • Goldenberg, N.M., Steinberg, B.E., Slutsky, A.S., and Lee, W.L., 2011, Broken barriers: A new take on sepsis pathogenesis. Science Translational Medicine, 3(88), 88ps25, DOI:10.1126/scitranslmed.3002011
  • Lattuada, M., Maripuu, E., Segerstad, C.H., Lundqvist H., and Hedenstierna, G., 2012, Evaluating abdominal oedema during experimental sepsis using an isotope technique. Clinical Physiology & Functional Imaging, 32, 197–204
  • Nohé, B., Ploppa, A., Schmidt, V., and Unertl, K., 2011, Volume replacement in intensive care medicine. Anaesthesist, 60, 457–464, 466–473
  • Bracco, D., Revelly, J.P., Berger, M.M., and Chioléro, R.L., 1998, Bedside determination of fluid accumulation after cardiac surgery using segmental bioelectrical impedance. Critical Care Medicine, 26, 1065–1070
  • Jaffrin, M.Y., and Morel, H., 2008, Body fluid volumes measurements by impedance: A review of bioimpedance spectroscopy (BIS) and bioimpedance analysis (BIA) methods. Medical Engineering & Physics, 30, 1257–1269
  • Durfee, W., Iaizzo, P., Burgstahler, B., and Ponkshe, S., 2010, Non-invasive muscle force assessment apparatus for use in the intensive care unit. Engineering in Medicine and Biology Society (EMBC), 2010 Annual International Conference of the IEEE. 5835–5838 (Buenos Aires, Argentina)
  • Ginz, H.F., Iaizzo, P.A., Urwyler, A., and Pargger, H., 2008, Use of non-invasive-stimulated muscle force assessment in long-term critically ill patients: A future standard in the intensive care unit? Acta Anaesthesiologica Scandinavica, 52, 20–27
  • Baker, L.L., Wederich C.L., McNeal D.R., Newsam C.J., and Waters R.L., 2000, NeuroMuscula [email protected] Electrical Stimulation – A Practical Guide, 4th ed., Los Amigos Research and Educational Institute: Downey, CA
  • Bracco, D., Thiébaud, D., Chioléro, R.L., Landry, M., Burckhardt, P., and Schutz, Y., 1996, Segmental body composition assessed by bioelectrical impedance analysis and DEXA in humans. Journal of Applied Physiology, 81, 2580–2587
  • Valentinuzzi, M.E., 1996, Bioelectrical impedance techniques in medicine. Part I: Bioimpedance measurement. First section: General concepts. Critical Reviews in Biomedical Engineering, 24, 223–255
  • Van Marken Lichtenbelt, W.D., Westerterp, K.R., Wouters, L., and Luijendijk, S.C., 1994, Validation of bioelectrical-impedance measurements as a method to estimate body-water compartments. American Journal of Clinical Nutrition, 60, 159–166
  • Winterhalter M., Münte S., Taschenbrecker P., Hecker H., Weilbach C., Osthaus A.W., Gross, M., Piepenbrock, S., and Rahe-Meyer, N., 2009, Skin impedance correlates to sedation grade, plasma propofol concentrations and bispectral index during a target-controlled infusion of propofol. European Journal of Anaesthesiology, 26, 589–596
  • Patterson, R., 2000, Bioelectric impedance measurements. In: Bronzino, J., editors. The Biomedical Engineering Handbook, 2nd edn. (Boca Raton, Florida, USA: CRC Press)
  • Van Boxtel A., 1977, Skin resistance during square-wave electrical pulses of 1 to 10 mA. Medical & Biological Engineering & Computing, 15, 679–687
  • Casley-Smith, J.R., 1988, Lack of correlation of oedema with electrical resistance of tissue. British Journal of Plastic Surgery, 41, 558–559
  • Sauter, A.R., Dodgson, M.S., Kalvøy, H., Grimnes, S., Stubhaug, A., and Klaastad, O., 2009, Current threshold for nerve stimulation depends on electrical impedance of the tissue: A study of ultrasound-guided electrical nerve stimulation of the median nerve. Anesthesia & Analgesia, 108, 1338–1343
  • Petrofsky, J., 2008, The effect of the subcutaneous fat on the transfer of current through skin and into muscle. Medical Engineering & Physics, 30, 1168–1176

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.