Biosensors: clinical requirements and scientific promise

Pages 51-56 | Published online: 09 Jul 2009

References

  • Updike J. W., Hicks J. P. The enzyme electrode. Nature 1967; 214: 986–988
  • Lowe C. The affinity electrode. FEBS Letters 1979; 106: 405–408
  • Keating M. Y., Rechnitz G. A. Potentio-metric digoxin antibody measurement with antigen-iono-phore based membrane electrodes. Analytical Chemistrv 1984; 56
  • Caras S. D., Petelenz D., Janata J. pH-based enzyme potentiometric sensors. Analytical Chemistry 1985; 57: 1920–1923
  • Caras S. D., Janata J. Penicillin-sensitive field effect transistor. Analytical Chemistry 1985; 57: 1924–1925
  • McKinley B. A., Saffle J., Jordan W. S., Janata J., Moss S. D., Westenskow D. R. In vivo continuous monitoring of K+ in animals using ISFET probes. Medical Instrumentation 1980; 14(2)93–97
  • Mosbach K., Mandenius C. F., Danielsson B. New biosensor devices. Biotech 83. Online Publications, Northwood 1983; 665–668
  • Roedere J. E., Bastiaans G. J. Microgravi-metric immunoassay with piezoelectric crystals. Analytical Chemistry 1983; 55: 2333–2336
  • Mansouri S., Schultz J. S. A miniature optical glucose sensor based on affinity binding. Biotechnology 1984; 885–890
  • Sutherland R., Dahne C, Place J. F., Ringrose A. S. Optical detection of antigen-antibody reactions at a glass-liquid interface. Clinical Chemistry 1984; 30: 1533–1538
  • Wolfson S. K., Tokarsky J. F., Yao S. J., Krupper M. A. Glucose concentration at possible sensor tissue implant sites. Diabetes Care 1982; 5: 162–165
  • Tchobroutsky G. Relation of diabetic control to development of microvascular complications. Diabetologia 1978; 15: 143–152
  • Pickup J. C, Keen H., Parsons J. A., Alberti K. G. M. Continuous insulin infusion: an approach to achieving normoglycaemia. British Medical Journal 1978; 1: 204–207
  • Tang S., Fui N G., Pickup J. C, Bending J. J., Collins A. C. G., Keen H., Dalton N. Hypoglycaemia and counter regulation in insulin-dependent diabetic patients: a comparison of continuous subcutaneous insulin infusion and conventional insulin therapy. Diabetes Care 1986; 9: 221–227
  • Unger R. H. Meticulous control of diabetes: benefits, risks and precautions. Diabetes 1982; 31: 479–483
  • Soldner J. S. Symposium on potentially implantable glucose sensors. Diabetes Care 1982; 5: 147–217
  • Gebhardt U., Luft G., Richter G. J., Von Sturm F. Development of an implantable electrocatalytic glucose sensor. Bioelectrochemistry and Bioenergetics 1978; 5: 607–624
  • Wingard L. B., Liu C. C, Wolfson S. K., Yao S. J., Drash A. L. Potentiometric measurement of glucose concentration with an immobilised glucose oxidase/ catalase electrode. Diabetes Care 1982; 6: 199–202
  • Gough D. A., Leypoldt J. K., Armour J. C. Progress towards a potentially implantable enzyme-based glucose sensor. Diabetes Care 1982; 5: 190–198
  • Nilsson H., Akerlund A. C., Mosbach K. Determination of glucose, urea and penicillin using enzyme pH electrodes. Biochemistry Biophysics Acta 1973; 320: 529–534
  • Romette J. L., Froment B., Thomas D. Glucose oxidase electrode. Measurement of glucose samples exhibiting a high variability in oxygen content. Clinica Chimica Acta 1979; 95: 249–253
  • Clark L. C., Duggan C. A. Implanted electroenzymatic glucose sensors. Diabetes Care 1982; 5: 174–180
  • Cass A. E. G., Davis G., Francis G. D., Hill H. A. O., Aston W. J. F., Iiggins I. J., Plotkin E. V., Scott L. D. L., Turner A. P. F. Ferrocene-mediated enzyme electrode for amperometric determination of glucose. Analytical Chemistry 1984; 56: 667–671
  • Shichiri M., Kawamori R., Yamasaki Y., Hakui X., Abe H. Wearable-type artificial endocrine pancreas with needle-type glucose sensor. Lancet 1982; 2: 1129–1131
  • Shichiri M., Kawamori Y., Goriya Y., Yamasaki Y., Nomura M., Hakui N., Abe H. Glycaemic control in pancreatectomised dogs with a wearable artificial endocrine pancreas. Diabetologia 1983; 24: 179–184
  • Shichiri M., Kawamori R., Hakui X., Yamasaki Y., Abe H. Diabetes 1984; 33: 1200–1202
  • Abel P., Muller A., Fischer U. Experience with an implantable glucose sensor as a prerequisite of an artificial beta cell. Biomed. Biochim. Acta 1984; 43: 577–584
  • Claremont D. J., Penton C., Pickup J. C. Potentially-implantable, ferrocene-mediated glucose sensor. Journal of Biomedical Engineering 1986; 8: 272–274
  • Claremont D. J., Sambrook I. E., Penton C., Pickup J. C. Diabetic Medicine, (in press)
  • March W. F., Engerman R., Rabinovitch B. Optical monitor of glucose. Transactions of the American Society for Artificial Internal Organs 1979; 25: 28
  • March W. F., Rabinovitch B., Adams R., Wise J. R., Melton M. Occular glucose sensor. Transactions of the American Society for Artificial Internal Organs 1982; xxviii: 232–235
  • Parker D., Key A., Davies R. S. Catheter-tip transducer for continuous in vivo measurement of oxygen tension. Lancet 1971; 1: 952
  • Moxham J., Armstrong R. F. Continuous monitoring of right atrial oxygen tension in patients with myocardial infarction. Intensive Care Medicine 1981; 7: 157–164
  • Pollitzer M. J., Souter L., Reynolds E. O. R., Whitehead M. D. Continuous monitoring of arterial oxygen tension infants: Four years of experience with an intravascular oxygen electrode. Paediatrics 1980; 66: 31–36
  • Eberhardt P., Hammacher K., Mindt W. Methode zur Kutanen Messung des Asuerstoff-Druckes. Biomedizinische Tecnik 1973; 6: 216–221
  • Continuous transcutaneous blood gas monitoring, A. Huch, R. Huch, J. R. Lucey. Birth Defects: Original Article Series xv, No. 4, Alan R. Liss, New York and Basel 1979
  • Hutchison D. S.C., Rocca G., Honeybourne D. Estimation of arterial oxygen tension in adult subjects using a transcutaneous electrode. Thorax 1981; 36: 473–477
  • Isenberg S. J., Shoemaker W. C. The transconjunctival oxygen monitor. American Journal of Ophthalmology 1983; 95: 803–806
  • Jamieson W. R. E., Turnbull K. W., Larriea A. J., Dodds W. A., Allison J. C., Tyers G. F. O. Continuous monitoring of mixed venous saturation in cardiac surgery. The Canadian Journal of Surgery 1982; 25(5)538–543
  • Webb S. C, Richards A. F., Poole-Wilson P. A. Coronary artery potassium recorded during coronary angioplasty. British Heart Journal 1983; 50: 146–148
  • Treasure T., Band B. M. A catheter-tip potassium selective electrode. Journal of Medical Engineering & Technology 1977

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.