2
Views
0
CrossRef citations to date
0
Altmetric
Original Article

A microcomputer-based system for the accurate continuous measurement of ventilation and blood pressure parameters under anaesthesia

, &
Pages 243-251 | Published online: 09 Jul 2009

References

  • Wright B.M. A respiratory anemometer. Journal of Physiology 1955; 127: 25
  • Nunn J.F., Ezi-Ashi T.I. The accuracy of the respirometer and ventigrator. British Journal of Anaesthesia 1962; 34: 422–432
  • Bushman J.A. Effect of different flow patterns on the Wright respirometer. British Journal of Anaesthesia 1979; 51: 895–898
  • Conway C.M., Leigh J.M., Preston T.D., Walters F.J.M., Webb D.A. An assessment of three electronic spirometers. British Journal of Anaesthesia 1974; 46: 885–891
  • Adams A.P., Vickers M.D.A., Munroe J.P., Parker C.W. Dry displacement gas meters 1967; 39: 174–183
  • Cooper E.A. The measurement of ventilation. British Journal of Anaesthesia 1969; 41: 718–722
  • Fry D.L., Hyatt R.E., McCall C.B., Mallos A.J. Evaluation of three types of respiratory flowmeters. Journal of Applied Physiology 1957; 10: 210–214
  • Grenvik A., Hedstrand U., Sjogren H. Problems in pneumotachography. Acta Anaesthesiologica Scandinavica 1966; 10: 147–155
  • Deno N.S., Bartlett H.L., Buskirk E.R. Respiratory flow integrator with improved stability. Journal of Applied Physiology 1978; 44: 619–622
  • Scott J.C., Flanagan G.J. Improvement of an infant pneumotachograph. Anaesthesia 1973; 28: 59–65
  • Epstein R.A., Epstein M.A.F. Automatic rezeroing of drifting physiologic signals. Medical and Biological Engineering and Computing 1980; 18: 746–748
  • Beatty P. Zero-drift correction device for a respiratory pneumotachograph. Medical and Biological Engineering and Computing 1983; 21: 109–112
  • Lundsgaard J.S., Gronlund J., Einer-Jensen N. Evaluation of a constant-temperature hot-wire anemometer for respiratory gas-flow measurements. Medical and Biological Engineering and Computing 1979; 17: 211–215
  • Konno K., Mead J. Measurement of the separate volume changes of rib cage and abdomen during breathing. Journal of Applied Physiology 1967; 22: 407–422
  • Mead J., Peterson N., Grimby G., Mead J. Pulmonary ventilation measured from body surface movements. Science 1967; 156: 1383–1384
  • Cohn M.A., Rao A.S.V., Broudy M., Birch S., Watson H., Atkins N., Davis B., Scott F.D., Sackner M.A. the respiratory inductive plethysmograph: a new non-invasive monitor of respiration. Bulletin of European Physiopathology and Respiration 1982; 18: 643–658
  • Ashutosh K., Gilbert R., Auchincloss J.H., Erlebacher J., Peppi D. Impedance pneumograph and magnetometer methods for monitoring tidal volume. Journal of Applied Physiology 1974; 37: 964–966
  • Nunn J.F. Applied Respiratory Physiology, 1st edn. Butterworths, London 1969; 83, 171
  • Cooper E.A. The estimation of minute volume. Anaesthesia 1959; 14: 373–378
  • Stephen G.W., Davie I., Scott D.B. A method of spirometry during general anaesthesia. British Journal of Anaesthesia 1970; 42: 109–112
  • Donald K.W., Christie R.V. A new method of clinical spirometry. Chemical Science 1949; 8: 21–31
  • Nunn J.F. Respiratory measurements in the presence of nitrous oxide. British Journal of Anaesthesia 1958; 30: 254–263
  • Nunn J.F. A new method of spirometry applicable to routine anaesthesia. British Journal of Anaesthesia 1956; 28: 440–449
  • Ditchburn R.K., Hull D., Segall M.M. Oxygen uptake during and after positive-pressure ventilation for the resuscitation of asphyxiated newborn infants. Lancet 1966; 2: 1096–1099
  • O'Connor S.A., Wilkinson D.J., Dickson G.R., Ashley B.J. Wet-wedge spirometer for the accurate continuous measurement of ventilation under anaesthesia. Medical and Biological Engineering and Computing 1985; 23: 258–262
  • Nott M.R., Norman J. Resistance of Heidbrink-type expiratory valves. British Journal of Anaesthesia 1978; 50: 477–480
  • Wilkinson D.J., O'Connor S.A., Dickson G.R., Drake H.F. Meptazinol-A cause of repiratory depression in general anaesthesia. British Journal of Anaesthesia 1985; 57: 1077–1084
  • O'Connor S.A., Wilkinson D.J. A double-blind study of the respiratory effects of Nalbuphine hydrochloride in spontaneously breathing anaesthetised patients. Anesthesia and Analgesia 1988; 67: 324–328
  • Lynn P.A. An Introduction to the Analysis and Processing of Signals. Macmillan Press, London 1973, Part 2, Signal Processing.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.