Clinical assessment of prosthetic valve function

&
Pages 15-22 | Published online: 09 Jul 2009

References

  • McClung J. A., Stein J. H., Ambrose J. A., Herman M. V., Reed G. E. Prosthetic heart valves: a review. Progress in Cardiovascular Disease 1983; 26: 237–270
  • Nanda N. C, Cooper J. W., Mahan E. F., Fan P. Echocardiographic assessment of prosthetic valves. Circulation 1991; 84(Suppl I)I-228–239
  • Rijsterborgh H., Mayala A., Forster T., Vletter W., Van Der Borden B., Sutherland G. R., Roelandt J. The reproducibility of continuous wave Doppler measurements in the assessment of mitral stenosis or mitral prosthetic function: the relative contributions of heart rate, respiration, observer variability and their clinical relevance. European Heart Journal 1990; 11: 592–600
  • Alam M., Serwin J. B., Polanco G. A., Sun I., Silverman H. A. Transesophageal echocardiographic features of normal and dysfunctioning biopros thetic valves. American Heart Journal 1991; 121: 1149–1155
  • Sprecher D. L., Adamick A., Adams D., Kisslo J. in vitro color flow and continuous wave Doppler ultrasound masking of flow by prosthetic valves. Journal of the American College of Cardiology 1987; 9: 1306–1310
  • van den Brink R., Visser C. A., Basart D. C. G., Düren D. R., de Jong A. P., Dunning A. J. Comparison of transthoracic and transesophageal color Doppler flow imaging in patients with a mechanical prosthesis in the mitral position. American Journal of Cardiology 1989; 63: 1471–1474
  • Bursteur D. J., Nishimura R. A., Bailey K. R., Reeder G. S., Holmes D. R., Seward J. B., Tajik A. J. Continuous wave Doppler echocardiographic measurement of prosthetic valve gradients. A simultaneous Doppler-catheter correlative study. Circulation 1989; 80: 504–514
  • Wllkins G. T., Glllam L. D., Kritzer G. L., Levine R. A., Palacios I. F., Weyman A. E. Validation of continuous wave Doppler echocardiographic measurements of mitral and tricuspid prosthetic valve gradients: a simultaneous Doppler-catheter study. Circulation 1986; 74: 786–795
  • Enriquez-Sarano M., Roger V., Vahanian A., Vitoux B., Cazaux O., Acar J. Mesure des gradients transvalvulaires par le Doppler. Enregistrements simultanes Doppler-catheterisme chez 78 patients. Archives des Maladies du Coeur et des Vaissaux 1987; 80: 1593–1601
  • Baumgartner H., Khan S., DeRobertis M., Czer L. S. C, Maurer G. Discrepancies between Doppler and catheter gradients in aortic prosthetic valves in vitro. A manifestation of localized gradients and pressure recovery. Circulation 1990; 82: 1467–1475
  • Ren J. F., Chandrasekaran K., Mintz G. S., Ross J., Pennock R. S., Frankl W. S. Effect of depressed left ventricular function on hemodynamics of a normal St Jude Medical prosthesis in the aortic valve position. American Journal of Cardiology 1990; 65: 1004–1009
  • Hatle L., Angelsen B., Tromsdal A. Non-invasive assessment of atrioventricular pressure half-time by Doppler ultrasound. Circulation 1979; 60: 1096–1104
  • Hatle L., Brubakk A., Tromsdal A., Angelsen B. Noninvasive assessment of pressure drop in mitral stenosis by Doppler ultrasound. British Heart Journal 1978; 40: 131–140
  • Holen J., Simonsen S. Determination of pressure gradient in mitral stenosis with Doppler echocardiography. British Heart Journal 1979; 41: 529–535
  • Chambers J., McLoughlin N., Rapson A., Jackson G. Effect of changes in heart rate on pressure half-time in normally functioning mitral valve prostheses. British Heart Journal 1988; 60: 502–506
  • Dumensil J. G., Honos G. N., Lemieux M., Beau-Chemin J. Validation and applications of mitral prosthetic valvular areas calculated by Doppler echocardiography. American Journal of Cardiology 1990; 65: 1443–1448
  • Wranne B., Ask P., Loyd D. Analysis of different methods of assessing the stenotic mitral valve area with emphasis on the pressure half-time concept. American Journal of Cardiology 1990; 66: 614–620
  • Chafizadeh E. R., Zoghbi W. A. Doppler echocardiographic assessment of the St Jude Medical prosthetic valve in the aortic position using the continuity equation. Circulation 1991; 83: 213–223
  • Reisner S. A., Meltzer R. S. Normal values of prosthetic valve Doppler echocardiographic parameters: a review. Journal of the American Society of Echocardiography 1988; 1: 201–210
  • Mohr-Kahaly S., Kupferwasser I., Erbel R., Oelert G., Meyer J. Regurgitant flow in apparently normal valve prostheses: improved detection and semi-quantitative analysis by transesophageal two-dimensional colour-coded Doppler echocardiography. Journal of the American Society of Echocardiography 1990; 3: 187–195
  • Klein A. L., Obarski T. P., Stewart W. J., Casale P. N., Pearce G. L., Husbands K., Cosgrove D. M., Salcedo E. E. Transesophageal Doppler echocardiography of pulmonary venous flow: a new marker of mitral regurgitation severity. Journal of the American College of Cardiology 1991; 18: 518–526
  • Perry G. J., Helmcke F., Nanda N. C, Byard C, Soto B. Evaluation of aortic insufficiency by Doppler color flow mapping. Journal of the American College of Cardiology 1987; 9: 952–959
  • Chen C, Thomas J. D., Anconina J., Harrigan P., Mueller L., Picard M. H., Levine R. A., Weyman A. E. Impact of impinging wall jet on color Doppler quantification of mitral regurgitation. Circulation 1991; 84: 712–720
  • Schoenfeld M. H., Palacios I. F., Hutter A. M., Jacoby S. S., Block P. C. Underestimation of prosthetic mitral valve areas: role of transseptal catheterization in avoiding unnecessary repeat mitral valve surgery. Journal of the American College of Cardiology 1985; 5: 1387–1392
  • Stewart S. F. C, Nast E. P., Arabia F. A., Talbot T. L., Proschan M., Clark R. E. Errors in pressure gradient measurement by continuous wave Doppler ultrasound: type, size and age effects in biopros thetic aortic valves. Journal of the American College of Cardiology 1991; 18: 769–779
  • Cannon S., Richards K., Crawford M. Hydraulic estimation of stenotic orifice area: a correction of the Gorlin formula. Circulation 1985; 72: 1170–1178
  • Aschenberg W., Schlüter M., Kremer P., Schröder E., Siglow V., Bleifeld W. Transesophageal two-dimensional echocardiography for the detection of left atrial appendage thrombus. Journal of the American College of Cardiology 1986; 7: 163–166
  • Mögge A., Daniel W. G., Haverich A., Lichtlen P. R. Diagnosis of noninfective cardiac mass lesions by two-dimensional echocardiography. Comparison of the transthoracic and transesophageal approaches. Circulation 1991; 83: 70–78
  • Daniel W. G., Nellessen U., Schröder E., Nonnast-Daniel B., Bednarski P., Nikutta P., Lichtlen P. R. Left atrial spontaneous echo contrast in mitral valve disease: an indicator for an increased thromboembolic risk. Journal of the American College of Cardiology 1988; 11: 1204–1211
  • Black I. W., Hopkins A. P., Lee L. C. L., Walsh W. F., Jacobson B. M. Left atrial spontaneous echo contrast: a clinical and echocardiographic analysis. Journal of the American College of Cardiology 1991; 18: 398–404
  • Beppu S., Nimura Y., Sakakibara H., Nagata S., Park Y.-D., Izumi S. Smoke-like echo in left atrial cavity in mitral valve disease: its features and significance. Journal of the American College of Cardiology 1985; 6: 744–749
  • Sigel B., Coelho J. C. U., Spigos D. G., Flanigan D. P., Schuler J. J., Kasprisin D. O., Nyhus L. M., Capek V. Ultrasonography of blood during stasis and coagulation. Investigative Radiology 1981; 16: 71–76
  • Machi J., Sigel B., Beitler J. C, Coelho J. C. U., Justin J. R. Relation of in vivo blood flow to ultrasound echogenicity. Journal of Clinical Ultrasound 1983; 11: 3–10
  • Pollick C, Taylor D. Assessment of left atrial appendage function by transesophageal echocardiography. Implications for the development of thrombus. Circulation 1991; 84: 223–231
  • Taams M. A., Gussenhoven E. J., Bos E., de Jaegere P., Roelandt J., Sutherland G. R., Bom N. Enhanced morphological diagnosis in infective endocarditis by transoesophageal echocardiography. British Heart Journal 1990; 63: 109–113
  • Erbel R., Rohmann S., Drexler M., Mohr-Kahaly S., Gerharz C. D., Iversen S., Oelert H., Meyer J. Improved diagnostic value of echocardiography in patients with infective endocarditis by transoesophageal approach. A prospective study. European Heart Journal 1988; 9: 43–53
  • Mögge A., Daniel W. G., Frank G., Lichtlen P. R. Echocardiography in infective endocarditis: reassessment of prognostic implications of vegetation size determined by the transthoracic and the transesophageal approach. Journal of the American College of Cardiology 1989; 14: 631–638

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.