6
Views
7
CrossRef citations to date
0
Altmetric
Original Article

Design and evaluation of an instrument to measure microcirculatory blood flow and oxygen saturation simultaneously

&
Pages 123-128 | Published online: 16 Apr 2010

References

  • Bonner R. F., Clem T. R., Bowen P. D., Bowman R. L. Laser Doppler continuous real-time monitor of pulsatile and mean blood flow in tissue microcirculation. Scattering Techniques Applied to Supramolecular and Non equilibrium Systems, S. Chen, B. Chu, R. Nossal. NATO Advanced Study Institutes Series, Series B Physics, Plenum Press, New York 1981; 685–701
  • Stern M. D., Lappe D. L., Bowen P. D., Chimosky J. E., Holloway G. A., Keiser H. R., Bowman R. L. Continuous measurement of tissue blood flow by laser-Doppler spectroscopy. American Journal of Physiology 1977; 232: H441–448
  • Yoshiya I., Shimada Y., Tanaka K. Spectrophotometric monitoring of arterial oxygen saturation in the fingertip. Medical and Biological Engineering and Computing 1980; 18: 27–32
  • Mendelson Y., Cheung P. W., Neuman M. R. Noninvasive monitoring of arterial blood oxygen saturation. IEEE/NSF Symposium on Biosensors 1984; 40–43
  • Mendelson Y., Kent J. C, Yocum B. L., Birle M. J. Design and evaluation of a new reflectance pulse oximeter sensor. Medical Instrumentation 1988; 22: 167–173
  • Shimada Y., Nakashima K., Fujiwara Y., Komatsu T., Kawanishi M., Takezawa J., Takatani S. Evaluation of a new reflectance pulse oximeter for clinical applications. Medical and Biological Engineering and Computing 1991; 29: 557–561
  • Nillson G. E., Tenland T., Oberg P. A. A new instrument for continuous measurement of tissue blood flow by light beating spectroscopy. IEEE Transactions on Biomedical Engineering 1980; 27: 12–19
  • Bonner R., Nossal R. Model for laser Doppler measurement of blood flow in tissue. Applied Optics 1981; 20: 2097–2107
  • Shimada Y., Yoshiya I., Oka N., Hamaguri K. Effects of multiple scattering and peripheral circulation on arterial oxygen saturation measured with a pulse-type oximeter. Medical and Biological Engineering and Computing 1984; 22: 475–478
  • Cope M., Delphy D. T. System for long-term measurement of cerebral blood and tissue oxygenation on newborn infants by near infra-red trans-illumination. Medical and Biological Engineering and Computing 1988; 26: 289–294
  • Tremper K. K., Barker S. J. Pulse oximetry. Anesthesiology 1989; 70: 98–108
  • Dougherty T. J., Lawrence G., Kaufman J. H., Boyle D., Weishaupt K. R., Goldfarb A. Photoradiation in the treatment of recurrent breast carcinoma. Journal of the National Cancer Institutes 1977; 62: 231–237
  • Feather J. W., Driver I., Leslie G., Hajizadeh-Saffar M., Gilson D., King P. R., Dixon B. Reflectance spectrophotometric investigation of tissue response in photodynamic therapy of cancer. SPIE Optical Fibers in Medicine III 1988; 906: 162–168
  • Mendelson Y., Ochs B. D. Noninvasive pulse oximetry utilizing skin reflectance photoplethysmography. IEEE Transactions on Biomedical Engineering 1988; 35: 798–805
  • Dougherty G., Barnett N. J., Pettinger S. J. A prototype instrument combining laser Doppler flowmetry and reflection pulse oximetry. Clinical Physics and Physiological Measurement 1992, In press
  • Takatani S., Noda H., Takano H., Akutsu T. A miniature hybrid reflection type optical sensor for measurement of hemoglobin content and oxygen saturation of whole blood. IEEE Transactions on Biomedical Engineering 1988; 35: 187–198
  • Pasyk K. A., Thomas S. V., Hassett C. A., Cherry G. W., Faller R. Regional differences in capillary density of the normal human dermis. Plastic and Reconstructive Surgery 1989; 939
  • Schmidt J. M., Meindl J. D., Mihm F. G. An integrated circuit-based optical sensor for in vivo measurement of blood oxygenation. IEEE Transactions on Biomedical Engineering 1986; 33: 98–107
  • Obeid A. N., Dougherty G., Pettinger S. J. In vivo comparison of a twin wavelength laser Doppler flowmeter using He-Ne and laser diode sources. Journal of Medical Engineering and Technology 1990; 14: 102–110
  • Altman D. G., Bland J. Measurement in medicine: the analysis of method comparison studies. Statistician 1983; 32: 307–317
  • Obeid A. N., Barnett N. J., Dougherty G., Ward G. A critical review of laser Doppler flowmetry. Journal of Medical Engineering and Technology 1990; 14: 178–181
  • Barnett N. J., Dougherty G., Pettinger S. J. Comparative study of two laser Doppler blood flowmeters. Journal of Medical Engineering and Technology 1990; 14: 243–249
  • Ward G., Dougherty G. Frequency control for a synchronous motor infusion pump. Measurement Science and Technology 1991; 2: 818–820
  • Johnson P. The development of breathing. The Physiological Development of the Fetus and Newborn, C. T. Jones. Academic Press, London 1985

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.