References

  • Brown B. H., Barber D. C. Electrical impedance tomography; the construction and application of electrical impedance images. Medical Progress through Technology 1987; 13: 69–75
  • Brown B. H., Barber D. C., Seager A. D. Applied potential tomography: possible clinical applications. Clinical Physics and Physiological Measurements 1985; 6(2)109–121
  • Davids S. G. Evaluation of applied potential tomography: a clinician's view. Clinical Physics and Physiological Measurements 1987; 8(Suppl. A)175–180
  • Brown B. H., Barber D. C. Possibilities and problems of real-time imaging of tissue resistivity. Clinical Physics and Physiological Measurements 1988; 9(Suppl. A)121–125
  • Harris N. D. Applications of electrical impedance tomography in respiratory medicine. PhD Thesis, 1991
  • Smith R. W. M., Brown B. H., Freeston I. L., McArdle F. J. (1990) Real-time electrical impedance tomography. Proceedings of the 3rd EC Workshop in EIT, Copenhagen, July, 1990
  • Volpe J. J. Current concepts in neonatal medicine: neonatal intraventricular haemorrhage. New England Journal of Medicine 1981; 304: 886–90
  • Murphy D., Burton P., Coombs R., Tarassenko L., Rolfe P. Impedance imaging in the newborn. Clinical Physics and Physiological Measurements 1989; 8(Suppl. A)131–40
  • Tarassenko L., Pidcock M. K., Murphy D. F., Rolfe P. (1985) The development of impedance imaging techniques for use in the newborn risk for intraventricular haemorrhage. IEEE International Conference Electric and Magnetic Fields in Medicine and Biology, London, December, 1985, 83–87
  • McArdle F. J., Brown B. H., Pearse R. G., Barber D. C. The effect of skull of low-birthweight neonates on applied potential tomography imaging of centralised resistivity changes. Clinical Physics and Physiological Measurements 1988; 9(suppl. A)55–60
  • Cole K. S., Curtis H. J. Electric impedance of the squid giant axon during activity. Journal of General Physiology 1939; 22: 649–70
  • Klivington K. A., Galambos R. Resistance shifts accompanying the evoked potential cortical response in the cat. Science, 157: 211–3
  • Holder D. S. Feasibility of developing a method of imaging neuronal activity in the human brain: a theoretical review. Medical and Biological Engineering and Computing 1987; 25: 2–11
  • Holder D. S., Gardner-Medwin A. R. Some possible neurological applications of applied potential tomography. Clinical Physics and Physiological Measurements, 9(Suppl. A)111–119
  • Holder D. S. Impedance changes during evoked nervous activity in human subjects: implications for the application of applied potential tomography (APT) to imaging neuronal discharge. Clinical Physics and Physiological Measurements 1989; 10(3)267–274
  • McArdle F. J. Investigation of cardiosynchronous images of the heart and head using Applied Potential Tomography. PhD Thesis, University of Sheffield. 1992
  • Harris N. D., Suggett A. J., Barber D. C., Brown B. H. Applied potential tomography; a new technique for monitoring respiratory function. Proceedings of the EEC Workshop on electrical impedance imaging. Clinical Physics and Physiological Measurements 1988; 9(Suppl. A)79–85
  • Harris N. D., Suggett A. J., Barber D. C., Brown B. H. Application of applied potential tomography (APT) in respiratory medicine. Clinicial Physics and Physiological Measurements 1987; 8(Suppl. A)155–165
  • Pomeranz M., Delgado F., Eiseman B. Clinical evaluation of transthoracic electrical impedance as a guide to intrathoracic fluid volumes. Annals of Surgery 1970; 171: 686–691
  • Kira S., Hukushima Y., Kitamura S., Ito A. Transthoracic impedance variations associated with respiration. Journal of Applied Physiology 1971; 30: 820–826
  • Kawakami K., Watanabe A., Kira A., Ikeda K., Kanno R. An analysis of the relationship between transthoracic impedance variations and thoracic diameter changes. Medical and Biological Engineering 1974; 446–453
  • Harris N. D. Applications of electrical impedance tomography in respiratory medicine. PhD Thesis, University of Sheffield. 1991
  • McArdle F. J., Suggett A. J., Brown B. H., Barber D. C. An assessment of dynamic images by applied potential tomography for monitoring pulmonary perfusion. Clinical Physics and Physiological Measurements 1988; 9(Suppl. A)87–91
  • Mohapatra S. N. Non-invasive Cardioavascular Monitoring by Electrical Impedance Techniques. Pitman, London 1981
  • Kubicek W. G., From A. H. L., Patterson R. P., Witsoe D. A., Castende A., Lilleki R. G., Ersek R. Impedance cardiography as a non-invasive means to monitor cardiac function. Journal of the Association for the Advancement of Medical Instrumentation 1970; 4: 79–84
  • Eyuboglu B. M., Brown B. H., Barber D. C. In vivo imaging of cardiac related impedance changes. IEEE Engineering in Medicine and Biology 1989; 8(1)39–45
  • Henderson R. P., Webster J. G. An impedance camera for spatially specific measurements of the thorax. IEEE Transactions in Biomedical Engineering 1978; BME-25: 250–254
  • Eyuboglu B. M., Brown B. H., Barber D. C., Seager A. D. Localisation of cardiac related impedance changes in the thorax. Clinical Physics and Physiological Measurements 1987; 8(Suppl. A)167–173
  • Eyuboglu B. M., Brown B. H., Barber D. C. Problems of cardiac output determination from electrical impedance tomography scans. Clinical Physics and Physiological Measurements 1988; 9(Suppl. A)71–77
  • Kim Y., Woo H. W., Luedtke A. E. Impedance tomography and its application in deep venous thrombosis detection. IEEE Engineering in Medicine and Biology 1989; 8(1)46–49
  • Brown B. H., Leathard A. D., Sinton A. M., McArdle F. J., Smith R. W. M., Barber D. C. Blood flow imaging using electrical impedance tomography. Clinical Physics and Physiological Measurements 1992; 13 A: 175–179
  • Thomas D. C., McArdle F. J., Rogers V. E., Beard R. W., Brown B. H. The suitability of applied potential tomography for the detection of pelvic congestion in women: a pilot study. Clinical Science 1993, (in press)
  • Avill R., Mangnall Y. F., Bird N. C., Brown B. H., Barber D. C., Seager A. D., Johnson A. G., Read N. W. Applied potential tomography a new non-invasive technique for measuring gastric emptying. Gastroenterology 1987; 92: 1019–1026
  • Mangnall Y. F., Baxter A. J., Avill R., Bird N. C., Brown B. H., Barber D. C., Seager A. D., Johnson A. G., Read N. W. Applied potential tomography: a new non-invasive technique for assessing gastric function. Clinical Physics and Physiological Measurements 1987; 8(Suppl. A)119–129
  • Baxter A. J., Mangnall Y. F., Loj E. H., Brown B. H., Barber D. C., Johnson A. G., Read N. W. Evalution of applied potential tomography as a new non-invasive gastric secretion test. Gut 1988; 29: 1730–1735
  • Evans D. F., Wright J. W. (1990) Is the acid suppression necessary when measuring gastric emptying using applied potential tomography?. Proceedings of the 3rd EC workshop on EIT, Copenhagen, July, 1990
  • Wright J. W., Evans D. F. (1990) Applied potential tomography (APT): a non-invasive method of detecting the migrating motor complex (MMC). Proceedings of the 3rd EC workshop on EIT, Copenhagen, July, 1990
  • Lamont G. L., Wright J. W., Evans D. F., Kapila L. An evaluation of applied potential tomography in the diagnosis of infantile hypertrofic pyloric stenosis. Clinical Physics and Physiological Measurements 1988; 9(Suppl. A)65–69
  • Conway J. Electrical impedance tomography for thermal monitoring of hyperthermia treatment: an assessment using in vitro, in vivo measurements. Clinical Physics and Physiological Measurements 1987; 8(Suppl. A)141–146
  • Cetas T. C. Will thermometric tomography become practical for hyperthermia treatment monitoring?. Cancer Research 1984; 44(Suppl.)4805s–4808s
  • Griffiths H., Ahmed A. Applied Potential Tomography for non-invasive temperature mapping in hyperthermia. Clinical Physics and Physiological Measurements 1987; 8(Suppl. A)147–153
  • Persson B. R. R., Borje B., Weber L. The use of electrical impedance tomography for non-invasive temperature monitoring in hyperthermia treatment of cancer. Proceedings of the 3rd EC workshop on EIT, Copenhagen, July, 1990
  • Amasha H. M., Anderson A. P., Conway J., Barber D. C. Quantitative assessment of impedance tomography for temperature measurements in microwave hyperthermia. Clinical Physics and Physiological Measurements 1988; 9(Suppl. A)49–53
  • Conway J., Hawley S., Seager A. D., Brown B. H., Barber D. C. Applied potential tomography (APT) for non-invasive thermal imaging during hyperthermia treatment. Electronic Letters 1985; 21(19)836–838
  • Conway J., Hawley M., Mangnall Y., Amasha H., Rhoon G. C. Experimental assessment of electrical impedance imaging for hyperthermia monitoring. Clinical Physics and Physiological Measurements 1992; 13 A: 185–189
  • Ritchie I. K., Kulkarni V., Hutchinson J. M. S., Chesney R. B., Gibson P. Impedance osteography: a technique to study the electrical characteristics of fracture healing. Biomedical Sciences Instrumentation, D. Carlson. Instrumentation Society of America, NC 1989; Vol. 25: 59–77
  • Kulkarni V., Hutchinson J. M. S., Mallard J. R. The Aberdeen impedance imaging system. Biomedical Sciences Instrumentation, D. Carlson. Instrumentation Society of America, NC 1989; Vol. 25: 47–58
  • Duck F. A. Physical Properties of Tissue. Academic Press, London 1990

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.