References
- Tesk J.A., Wiedera O. Stress distribution in bone arising from loading on endosteal dental implants. Journal of Biomedical Materials Research 1973; 4: 251–261
- Privitzer E., Wiedera O., Tesk J.A. Some factors affecting dental implant design. Journal of Biomedical Materials Research 1975; 6: 251–260
- Takahashi N., Kitagami T., Komori T. Analysis of stress on a fixed denture with a blade-vent implant abutment. Journal of Prosthetic Dentistry 1978; 40(2)186–191
- Siegel D., Soltesz U. Numerical investigation of the influence of implant shape on stress distribution in the jaw bone. International Journal of Oral & Maxillofacial Implants 1989; 4(4)333–340
- French A.A., Bowles C.Q., Parham P.L., Eick J.D., Killoy W.J., Cobb C.M. Comparison of periimplant stresses transmited by four commercially available osseointegrated implants. International Journal of Periodontics & Resotrative Dentistry 1989; 9(9)221–230
- Rieger M.R., Adams W.K., Kinzel G.L. A finite element survey of eleven endosseous implants. Journal of Prosthetic Dentistry 1991; 63(4)457–465
- Rieger M.R., Adams W.K, Kinzel G.L., Brose M.O. Finite element analysis of bone-adapted and bone-bonded endosseous implants. Journal of Prosthetic Dentistry 1990; 62: 436–440
- Rieger M.R., Fareed K., Adams W.K. Bone stress distribution for three endosseous implants. Journal of Prosthetic Dentistry 1989; 61(2)223–228
- Rieger M.R., Mayberry M., Brose M.O. Finite element analysis of six endosseous implants. Journal of Prosthetic Dentistry 1991; 63(6)671–676
- Knoell A.C. A mathematical model of an in vitro human mandible. Journal of Biomechanics 1977; 10: 159–169
- Cook S.D., Weinstein A.M., Klawitter J.J. A three dimensional finite element analysis of a porous rooted Co-Cr-Mo alloy dental implant. Journal of Dental Research 1982; 61(1)25–29
- Lavernia C.J., Cook S.D., Weinstein A.M., Klawitter J.J. An analysis of stresses in a dental system. Journal of Biomechanics 1981; 14(8)555–560
- Ko C.C., Kohn D.H., Hollister S.J. Micromechanics of implant tissue interfaces. Journal of Oral Implantology 1992; 18(3)220–230
- Kohn D.H., Ko C.C., Hollister S.J. Localized mechanics of dental implants. BED Bioengineering Conference, ASME 1993; 24: 331–334
- Lee J., Koh C.S., Choi K. Stress analysis of dental implant using homogenization technique. Journal of Korean Dental Association 1994; 32(11)805–814
- Choi K., Kuhn J.L., Ciarelli M.J., Goldstein S.A. The elastic moduli of human subchondral, trabecular, and cortical bone tissue and the sizedependency of cortical bone modulus. Journal of Biomechanics 1990; 23(11)1103–1113