REFERENCES
- Herzen J, Todorovic M, Cermers F, Platz V, Albers D, Bartels A, Schmidt R. Dosimetric evaluation of a 2D pixel ionization chamber for implementation in clinical routine. Phys Med Biol 2007;52(4):1197–1208.
- Buonamici FB, Compagnucci A, Marrazzo L, Russo S, Bucciolini M. An intercomparison between film dosimetry and diode matrix for IMRT quality assurance. Med Phys 2007;34(4):1372–1379.
- Bucciolini M, Bounamici FB, Casati M. Verification of IMRT fields by film dosimetry. Med Phys 2004;31(1):161–168.
- Ju SG, Ahn YC, Huh SJ, Yeo IJ. Film dosimetry for intensity modulated radiotherapy: Dosimetric evaluation. Med Phys 2002;29(3):315–325.
- van Elmpt W, McDermott L, Nijsten S, Wendling M, Lambin P, Mijnheer B. A literature review of electronic portal imaging for radiotherapy dosimetry. Radiother Oncol 2008;88:289–309.
- Zhu Y, Jiang XQ, Vandyk J. Portal dosimetry using a liquid ion chamber matrix: Dose response studies. Med Phys 1995;22: 1101–1106.
- Mijnheer none B. State of the art of in-vivo dosimetry. Radiat Prot Dosimetry 2008;131:117–122.
- Martens C, De Wagter C, De Neve W. The value of the LA48 linear ion chamber for characterization of intensity-modulated beams. Phys Med Biol 2001;46(4):1131–1148.
- Stasi M, Baiotto B, Barboni G, Scielzo G. The behavior of several microionization chambers in small intensity modulated radiotherapy fields. Med Phys 2004;31(10):2792–2795.
- Spezi E, Angelini AL, Romani F, Ferri A. Characterization of a 2D ion chamber array for the verification of radiotherapy treatments. Phys Med Biol 2005;50(14):3361–3373.
- Jursinic PA, Nelms BE. A 2-D diode array and analysis software for verification of intensity modulated radiation therapy delivery. Med Phys 2003;30(5):870–879.
- Wagner D, Vorwerk H. Two years experience with quality assurance protocol for patient related Rapid Arc treatment plan verification using a two dimensional ionization chamber array. Radiat Oncol 2011;6:21–28.
- Nelms BE, Zhen H, Tomé WA. Per-beam, planar IMRT QA passing rates do not predict clinically relevant patient dose errors. Med Phys 2011;38(2):1037–1044.
- Boggula R, Lorenz F, Mueller L, Birkner M, Wertz H, Stieler F, Steil V, Lohr F, Wenz F. Experimental validation of a commercial 3D dose verification system for intensity-modulated arc therapies. Phys Med Biol 2010;55(19):5619–5633.
- Boggula R, Jahnke L, Wertz H, Lohr F, Wenz F. Patient-specific 3D pretreatment and potential 3D online dose verification of Monte Carlo-calculated IMRT prostate treatment plans. Int J Radiat Oncol Biol Phys 2011;81(4):1168–1175.
- Korevaar EW, Wauben DJ, van der Hulst PC, Langendijk JA, Van't Veld AA. Clinical introduction of a linac head-mounted 2D detector array based quality assurance system in head and neck IMRT. Radiother Oncol 2011;100(3):446–452.
- Zhen H, Nelms BE, Tomé WA. Moving from gamma passing rates to patient DVH-based QA metrics in pretreatment dose QA. Med Phys 2011;38:5477–5489.
- Korevaar EW, Wauben DJ, van der Hulst PC, Langendijk JA, Van't Veld AA. Clinical introduction of a linac head-mounted 2D detector array based quality assurance system in head and neck IMRT. Radiother Oncol 2011;100(3):446–452.
- Stasi M, Bresciani S, Miranti A, Maggio A, Sapino V. Pretreatment patient-specific IMRT quality assurance: A correlation study between gamma index and patient clinical dose volume histogram. Med Phys 2012;39(12):7626–7634.