The GlucoWatch® biographer: a frequent, automatic and noninvasive glucose monitor

, , , , , & show all
Pages 632-641 | Published online: 27 Sep 2010

References

  • The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. The Diabetes Control and Complications Trial Research Group. N Engl J Med 1993; 329: 977–86.
  • Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33). UK Prospective Diabetes Study (UKPDS) Group. Lancet 1998; 352: 837–53.
  • Bolinder J, Hagstrom-Toft E, Ungerstedt U, Amer P. Self-monitoring of blood glucose in type 1 diabetic patients: comparison with continuous microdialysis measurements of glucose in subcutaneous adipose tissue during ordinary life conditions. Diabetes Care 1997; 20: 64–70.
  • Retinopathy and nephropathy in patients with type 1 diabetes four years after a trial of intensive therapy. The Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications Research Group. N Engl J Med 2000; 342: 381–9.
  • Ginsberg BH. An overview of minimally invasive technolo-gies. Clin Chem 1992; 38: 1596–600.
  • Gabriely I, Wozniak R, Mevorach M, Kaplan J Aharon Y Shamoon H. Transcutaneous glucose measurement using near-infrared spectroscopy during hypoglycemia. Diabetes Care 1999; 22: 2026–32.
  • Bermeister JJ, Arnold MA, Small GW. Noninvasive blood glucose measurements by near-infrared transmission spec-troscopy across human tongues. Diab Tech Ther 2000; 2: 5–16.
  • Arnold MA, Burmeister JJ, Small GW. Phantom glucose calibration models from simulated noninvasive human near-infrared spectra. Anal Chem 1998; 70: 1773.
  • Wilson GS, Zhang Y, Reach G, Moatti-Sirat G, Poitout V, Thevenot DR, et al. Progress toward the development of an implantable sensor for glucose. Clin Chem 1992; 38: 1613–7.
  • Gross TM, Bode BW, Einhorn D, Kayne DM, Reed JH, White NH, et al. Performance evaluation of the MiniMed continuous glucose monitoring system during patient home use. Diab Tech Ther 2000; 2: 49–56.
  • Kurnik RT, Berner B, Tamada J, Potts RO. Design and simulation of a reverse iontophoretic glucose monitoring device. Electrochem Soc 1998; 145: 4119–25.
  • Singh J, Dinh SM, Berner B. Electrical properties of skin. In: Berner B, Dinh SM, eds. Electronically controlled drug delivery. Boca Raton, LA: CRC Press; 1998: 47–62.
  • Glikfeld P, Hinz RS, Guy RH. Noninvasive sampling of biological fluids by iontophoresis. Pharm Res 1989; 6: 988–90.
  • Rao G, Glikfeld P, Guy RH. Reverse iontophoresis: develop-ment of a noninvasive approach for glucose monitoring. Pharm Res 1993; 10: 1751–5.
  • Tamada JA, Bohannon NJV, Potts RO. Measurement of glucose in diabetic subjects using noninvasive transdermal extraction. Nat Med 1995; 1: 1198–201.
  • Tierney MJ, Jayalakshmi Y, Parris NA, Reidy MP, Uhegbu C, Vijayakumar P. Design of a biosensor for continual, transdermal glucose monitoring. Clin Chem 1999; 45: 1681–3.
  • Tierney MJ, Kim HL, Burns MD, Tamada JA, Potts RO. Electroanalysis of glucose in transcutaneously extracted samples. Electroanalysis 2000; 12: 666–71.
  • Tamada JA, Garg S, Jovanovic L, Pitzer KR, Fermi S, Potts RO. Noninvasive glucose monitoring: comprehensive clinical results. JAMA 1999; 282: 1839–44.
  • Garg SK, Potts RO, Ackerman NR, Fermi SJ, Tamada JA, Chase HP. Correlation of fingerstick blood glucose measure-ments with GlucoWatch biographer glucose results in young subjects with type 1 diabetes. Diabetes Care 22: 1708–14, 1999.
  • Kurnik R, Oliver JJ, Waterhouse SR, Dunn T, Jayalakshmi Y, Lesho M, et al. Application of the mixtures of experts algorithm for signal processing in a noninvasive glucose monitoring system. Sens Act B 1999; 60: 1–8.
  • Tamada JA, Jovanovic L, Garg S, Ackerman NR, Fermi S, Potts RO, et al. Evaluation of the GlucoWatch biographer: an automatic and non-invasive glucose monitor. Diabetes 2000; 49: A127.
  • Tierney MJ, Garg S, Ackerman NR, Fermi SJ, Kennedy J, Lopatin M, et at. Effect of acetaminophen on the accuracy of glucose measurements obtained with the GlucoWatch biographer. Diab Tech Ther 2000; 2: 197–205.
  • Clarke WL, Cox D, Gonder-Frederick LA, Carter W, Pohl SL. Evaluating clinical accuracy of systems for self-monitoring of blood glucose. Diabetes Care 1987; 10: 622–8.
  • Kilpatrick ES, McLeod MJ, Rumley AG, Small M. A ward comparison between the One Touch II and Glucometer II blood glucose meters. Diabet Med 1994; 11: 214–7.
  • Edelman S, Pitzer KR, Desai S, Dunn TC, Jayalakshmi Y. Detection of hypoglycemia and hyperglycemia with the GlucoWatch biographer. Diabetes 2000; 49 (Suppl 1): A104.
  • American Diabetes Association. Standards of medical care for patients with diabetes mellitus. Diabetes Care 2000; 23: S32–42.
  • Harris MI, Eastman RC, Cowie CC, Flegal KM, Eberhardt MS. Racial and ethnic differences in glycemic control of adults with type 2 diabetes. Diabetes Care 1999; 22: 403–8.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.