REFERENCES
- Ko Y, Liu CJ, Hsu W. Varying effects of corneal thickness on intraocular pressure measurements with different tonometers. Eye 2004;19:327–332
- Tonnu P, Ho T, Newson T, et al. The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry. Br J Ophthalmol 2005;89:851–854
- Zadok D, Tran DB, Twa M, et al. Pneumotonometry versus Goldmann tonometry after laser in situ keratomileusis for myopia. J Cataract Refract Surg 1999;25:1344–1348
- Mardelli PG, Piebenga LW, Whitacre MM, Siegmund KD. The effect of excimer laser photorefractive keratectomy on intraocular pressure measurements using the Goldmann applanation tonometer. Ophthalmology 1997;104:945–948
- Whitacre MM, Stein R. Sources of error with use of Goldmann-type tonometers. Surv Ophthalmol 1993;38:1–30
- Orssengo GJ, Pye DC. Determination of the true intraocular pressure and modulus of elasticity of the human cornea in vivo. Bull Math Biol 1999;61:551–572
- Siganos DS, Papastergiou GI, Moedas C. Assessment of the Pascal dynamic contour tonometer in monitoring intraocular pressure in unoperated eyes and eyes after LASIK. J Cataract Refract Surg 2004;30:746–751
- Swarbrick HA. Orthokeratology review and update. Clin Exp Optom 2006;89:124–143
- Mitchell P, Hourihan F, Sandbach J, Wang JJ. The relationship between glaucoma and myopia: the Blue Mountains eye study. Ophthalmology 1999;106(10):2010–2015
- Leske MC, Heijl A, Hussein M, et al. Factors for glaucoma progression and the effect of treatment: the early manifest glaucoma trial. Arch Ophthalmol 2003;121:48–56
- Noecker RS, Dirks MS, Choplin NT, et al. A six-month randomized clinical trial comparing the intraocular pressure-lowering efficacy of bimatoprost and latanoprost in patients with ocular hypertension or glaucoma. Am J Ophthalmol 2003;135:55–63
- Young AL, Leung ATS, Cheng LL, et al. Orthokeratology lens-related corneal ulcers in children: a case series. Ophthalmology 2004;111:590–595
- Lang J, Rah MJ. Adverse corneal events associated with corneal reshaping: a case series. Eye Contact Lens 2004;30:231–233
- Shehadeh-Masháour R, Segev F, Barequet I, et al. Orthokeratology associated microbial keratitis. Eur J Ophthalmol 2009;19:133–136
- Reinstein DZ, Gobbe M, Archer TJ, et al. Epithelial, stromal, and corneal pachymetry changes during orthokeratology. Optom Vis Sci 2009;86:E1006–1014
- Alharbi A, Swarbrick HA. The effects of overnight orthokeratology lens wear on corneal thickness. Invest Ophthalmol Vis Sci 2003;44:2518–2523
- Wolfs RCW, Klaver CCW, Vingerling JR, et al. Distribution of central corneal thickness and its association with intraocular pressure: the Rotterdam Study. Am J Ophthalmol 1997;123:767–772
- Bron AM, Creuzot-Garcher C, Goudeau-Boutillon S, d’Athis P. Falsely elevated intraocular pressure due to increased central corneal thickness. Graef Arch Clin Exp 1999;237:220–224
- Doughty MJ, Zaman ML. Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol 2000;44:367–408
- Aristeidou AP, Labiris G, Katsanos A, et al. Comparison between Pascal dynamic contour tonometer and Goldmann applanation tonometer after different types of refractive surgery. Graef Arch Clin Exp 2011;249:767–773
- Oncel B, Dinc U, Orge F, Yalvac B. Comparison of IOP measurement by ocular response analyzer, dynamic contour, Goldmann applanation, and noncontact tonometry. Eur J Ophthalmol 2009;19:936–941
- Matsumoto T, Makino H, Uozato H, et al. The influence of corneal thickness and curvature on the difference between intraocular pressure measurements obtained with a non-contact tonometer and those with a Goldmann applanation tonometer. Jpn J Ophthalmol 2000;104:317–323
- Papastergiou GI, Kozobolis V, Siganos DS. Assessment of the pascal dynamic contour tonometer in measuring intraocular pressure in keratoconic eyes. J Glaucoma 2008;17:484–488
- Portney LG, Watkins MP. Foundations of Clinical Research: applications to Practice, 3rd ed.; Upper Saddle River, NJ: Pearson/Prentice Hall, 2009
- Kohlhaas M, Boehm AG, Spoerl E, et al. Effect of central corneal thickness, corneal curvature, and axial length on applanation tonometry. Arch Ophthalmol 2006;124:471–476
- Hjortdal JO, Jensen PK. In vitro measurement of corneal strain, thickness, and curvature using digital image processing. Acta Ophthalmol Scand 1995;73:5–11
- Stillitano IG, Chalita MR, Schor P, et al. Corneal changes and wavefront analysis after orthokeratology fitting test. Am J Ophthalmol 2007;144:378–386
- Cheah PS, Norhani M, Bariah MA, et al. Histomorphometric profile of the corneal response to short-term reverse-geometry orthokeratology lens wear in primate corneas: a pilot study. Cornea 2008;27:461–470
- Chen D, Lam AKC, Cho P. A pilot study on the corneal biomechanical changes in short term orthokeratology. Ophthalmic Physiol Opt 2009;29:464–471
- Ishida Y, Yanai R, Sagara T, et al. Decrease in intraocular pressure following orthokeratology measured with a noncontact tonometer. Jpn J Ophthalmol 2011;55:190–195