2,099
Views
9
CrossRef citations to date
0
Altmetric
Original Articles

Treatment of Severe Aortic Bleeding Using Hemopatch in Swine on Dual Antiplatelet Therapy

, DVM, PhD, , MSc & , DVM
Pages 343-351 | Received 19 Oct 2015, Accepted 11 Feb 2016, Published online: 22 Mar 2016

REFERENCES

  • Patel PA, Fleisher LA. Aspirin, clopidogrel, and the surgeon. Adv Surg. 2014;48(1):211–222.
  • Kozuma K. Antiplatelet therapy during perioperative period: Double-edged sword. J Cardiol. 2014;64(5):331–333.
  • Yamamoto K, Wada H, Sakakura K, et al. Cardiovascular and bleeding risk of non-cardiac surgery in patients on antiplatelet therapy. J Cardiol. 2014;64(5):334–338.
  • Devereaux PJ, Mrkobrada M, Sessler DI, et al. Aspirin in patients undergoing noncardiac surgery. N Engl J Med. 2014;370(16):1494–1503.
  • Alghamdi AA, Moussa F, Fremes SE. Does the use of preoperative aspirin increase the risk of bleeding in patients undergoing coronary artery bypass grafting surgery? Systematic review and meta-analysis. J Card Surg. 2007;22(3):247–256.
  • Gabay M. Absorbable hemostatic agents. Am J Health Syst Pharm. 2006;63(13):1244–1253.
  • Lewis KM, Spazierer D, Slezak P, et al. Swelling, sealing, and hemostatic ability of a novel biomaterial: A polyethylene glycol-coated collagen pad. J Biomater Appl. 2014;29(5):780–788.
  • TachoSil Prescribing Information. Available from: http://www.tachosilus.com/pdfs/TachoSil_PI.pdf. Cited Jan 1, 2014.
  • Hemopatch Instructions for Use: Available from: http://hemopatch.com/int/pdf/HEMOPATCH_IFU.pdf. Cited Jan 1, 2014.
  • Institute for Laboratory Animal Research. Guide for the Care and Use of Laboratory Animals, 8th ed.; Washington, DC: The National Academies Press; 2011. Available from: https://www.aaalac.org/resources/theguide.cfm
  • Agger P, Langhoff J, Smerup M, et al. Comparison between TachoComb and TachoSil for surgical hemostasis in arterial bleeding: An animal experimental study. J Trauma. 2010;68:838–842.
  • Makkar RR, Eigler NL, Kaul S, et al. Effects of clopidogrel, aspirin and combined therapy in a porcine ex vivo model of high-shear induced stent thrombosis. Eur Heart J. 1998;19(10):1538–1546.
  • R Core Team. R: A Language and Environment for Statistical Computing. Vienna, Austria: R Foundation for Statistical Computing; 2013. URL: http://www.R-project.org/
  • Fay MP, Shaw PA. Exact and asymptotic weighted logrank tests for interval censored data: The interval R package. J Stat Softw. 2010;36(2):1–34.
  • Therneau T. A Package for Survival Analysis in S. R package version 2.37–7. 2014. URL: http://CRAN.R-project.org/package=survival
  • Swindle MM, Makin A, Herron AJ, et al. Swine as models in biomedical research and toxicology testing. Vet Pathol. 2012;49(2):344–356.
  • Byrom MJ, Bannon PG, White GH, et al. Animal models for the assessment of novel vascular conduits. J Vasc Surg. 2010;52(1):176–195.
  • Gutierrez G, Reines HD, Wulf-Gutierrez ME. Clinical review: Hemorrhagic shock. Crit Care. 2004;8(5):373–381.
  • Celiento M, Scioti G, Pratali S, et al. Repair of coronary artery perforation following angioplasty using TachoSil patches. Interact Cardiovasc Thorac Surg. 2010;10(2):328–330.
  • Fiore A, Grandmougin D, Maureira J, et al. Efficacy of TachoSil® as a sutureless hemostatic patch to repair a perforation of the interventricular groove during endocardial radiofrequency ablation. J Cardiovasc Surg. 2014;55(2):295–298.
  • Lewis KM, McKee J, Schiviz A, et al. Randomized, controlled comparison of advanced hemostatic pads in hepatic surgical models. ISRN Surg. 2014;2014:1–7.
  • Lewis KM, Schiviz A, Hedrich HC, et al. Hemostatic efficacy of a novel, PEG-coated collagen pad in clinically relevant animal models. Int J Surg. 2014;12(9):940–944.
  • Matonick JP, Hammond J. Hemostatic efficacy of EvarrestTM, fibrin sealant patch vs. TachoSil® in a heparinized swine spleen incision model. J Investig Surg. 2014;27(6):360–365.
  • Nieswandt B, Watson SP. Platelet-collagen interaction: Is GPVI the central receptor? Blood. 2003;102(2):449–461.
  • Nuyttens BP, Thijs T, Deckmyn H, et al. Platelet adhesion to collagen. Thromb Res. 2011;127(SUPPL. 2):S26– S29.
  • Mädler S, Bich C, Touboul D, et al. Chemical cross-linking with NHS esters: A systematic study on amino acid reactivities. J Mass Spectrom. 2009;44(5):694–706.
  • Wallace DG, Cruise GM, Rhee WM, et al. A tissue sealant based on reactive multifunctional polyethylene glycol. J Biomed Mater Res. 2001;58(5):545–555.
  • Imkamp F, Tolkach Y, Wolters M, et al. Initial experiences with the Hemopatch® as a hemostatic agent in zero-ischemia partial nephrectomy. World J Urol. 2015;33(10):1527–1534.
  • Prestipino F, Nenna A, Casacalenda A, et al. Ventricular perforation by pacemaker lead repaired with two hemostatic devices. Int J Surg. 2014;5(12):906–908.
  • Fingerhut A, Uranues S, Ettorre GM, et al. European initial hands-on experience with Hemopatch, a novel sealing hemostatic patch: Application in general, gastrointestinal, biliopancreatic, cardiac, and urologic surgery. Surg Technol Int. 2014;25:29–35.
  • Jainandunsing JS, Al-Ansari S, Woltersom BD, et al. Novel hemostatic patch achieves sutureless epicardial wound closure during complex cardiac surgery, a case report. J Cardiothorac Surg. 2015;10(1):10–12.
  • Erdas E, Medas F, Podda F, et al. The use of a biologic topical haemostatic agent (TachoSil®) for the prevention of postoperative bleeding in patients on antithrombotic therapy undergoing thyroid surgery: A randomised controlled pilot trial. Int J Surg. 2015;20: 95–100.
  • Aoyagi S, Tayama K, Otsuka H, et al. Sutureless repair for left ventricular free wall rupture after acute myocardial infarction. J Card Surg. 2014;29(2):178–180.