- Jansen J A, van der Waerden J PCM, de Groot K. Epithelial reaction to percutaneous implant materials: in vivo and in vitro experiments. J Invest Surg. 1989; 2: 29–49
- Jansen J A, van der Waerden J PCM, van der Lubbe H BM, de Groot K. Tissue response to percutaneous implants in rabbits. J Biomed Mater Res. 1990; 24: 295–307
- Jansen J A, van der Waerden J PCM, de Groot K. Wound-healing phenomena around percutaneous devices implanted in rabbits. J Mater Sci Mater Med. 1990; 1: 192–197
- Albrektsson T, Brånemark P-I, Jacobsson M, Tjellström A. Present clinical applications of osseointegrated percutaneous implants. Plast Reconstr Surg. 1987; 79: 721–730
- Holgers K M, Tjellström A, Bjursten L M, Erlandsson B. F. Soft tissue reactions around percutaneous implants: clinical study on skin-penetrating titanium implants used for bone-anchored auricular prostheses. Int J Oral Maxillofac. Implants 1987; 2: 35–39
- Holgers K M, Tjellström A, Bjursten L M, Erlandsson B. E. Soft tissue reactions around percutaneous implants: a clinical study of soft tissue conditions around skin-penetrating titanium implants for bone-anchored hearing aids. Am J Oto. 1988; 9: 56–59
- Tjellström A, Rosenhall U, Lindströ J, Hallén O, Albrektsson T, Bråanemark P-I. Five-year experience with skin-penetrating bone-anchored implants in the temporal bone. Acta Otolaryngol. 1983; 95: 568–575
- Tjellström A, Jacobsson M, Albrektsson T, Jansson K. Use of tissue integrated implants in congenital aural malformations. Adv Otorhinolaryng. 1988; 40: 24–32
- Tjellström A. Osseointegrated implants for replacement of absent or defective ears. Clin Plast Surg. 1990; 17: 355–366
- de Groot K, Geesink R, Klein C PAT, Serekian P. Plasma sprayed coatings of hydroxylapatite. J Biomed Mater Res. 1987; 21: 1375–1382
- Denissen H W, de Groot K, Makkes P CH, van den Hooff A, Klopper P. J. Tissue response to dense apatite implants in rats. J Biomed Mater Res. 1980; 14: 713–721
- van der Lubbe H BM, Klein C PAT, de Groot K. A simple method for preparing thin (10 μm) histological sections of undecalcified plastic embedded bone with implants. Stain Technol. 1988; 63: 171–177
- von Recum A F. Applications and failure modes of percutaneous devices: a review. J Biomed Mater Res. 1984; 18: 323–336
- Kobashi L I, Raible D. A. Biocarbon urinary conduit: laboratory experience and clinical applications. Urology 1980; 16: 27–32
- Måansson W, Harzmann R. Clinical experience with an alloplastic stoma prosthesis (biocarbon) for urinary conduits and cutaneous ureterostomy. Scand J Urol Nephrol. 1988; 22: 223–226
- Krouskop T A, Brown H D, Gray K, et al. Bacterial challenge study of a porous carbon percutaneous implant. Biomaterials. 1988; 9: 398–404
- Aoki H, Akao M, Shin Y, Tsuzi T, Togawa T. Sintered hydroxyapatite for a percutaneous device and its clinical application. Med Prog Technol. 1987; 12: 213–220
- Daly B DT, Dasse K A, Gould K E, et al. A new percutaneous access device for peritoneal analysis. Trans Am Soc Artif Intern Organs 1987; 33: 664–671
- Cruz C. The peritoneoscopic implantation of a polyurethane percutaneous access device for peritoneal dialysis: preliminary experience. ASAIO Trans. 1988; 34: 941–944
- Jansen J A, van der Waerden J PCM, de Groot K. A new method for the stabilization of percutaneous devices in soft tissues. 16th Annual Meeting of the Society for Biomaterials. 1990; 300
- Kantrowitz A, Freed P S, Ciarkowski A A, et al. Development of a percutaneous access device. Trans Am Soc Artif Intern Organs 1980; 26: 444–449
- Kantrowitz A, Daly B DT, Hermann V M, Twardowski Z J, Cruz C. Development of a new long-term access device for continuous ambulatory peritoneal dialysis. Trans Am Soc Artif Intern Organs 1988; 34: 930–931
- Freed P S, Wasfie T, Bar-Lev A, et al. Long-term percutaneous access device. Trans Am Soc Artif Intern Organs 1985; 31: 230–234
- Dunn G A, Heath J. P. A new hypothesis of contact guidance in tissue cells. Exp Cell Res. 1976; 101: 1–14
- Brunette D. M. The effects of implant surface topography on the behavior of cells. Int J Oral Maxillofac Implants 1988; 3: 231–246
- Chehroudi B, Gould T RL, Brunette D. M. Effects of a grooved titanium-coated implant surface on epithelial cell behavior in vitro and in vivo. J Biomed Mater Res. 1989; 23: 1067–1085
- Chehroudi B, Gould T RL, Brunette D. M. Titanium-coated micromachined grooves of different dimensions affect epithelial and connective-tissue cells differently in vivo. J Biomed Mater Res. 1990; 24: 1203–1219
- Pfingst B E, Albrektsson T, Tjellström A, et al. Chronic skull-anchored percutaneous implants in non-human primates. J Neurosci Methods 1989; 29: 207–216