99
Views
5
CrossRef citations to date
0
Altmetric
Original Article

Bipolar Pacemaker Leads: New Materials, New Technology

&
Pages 75-81 | Received 05 Nov 1997, Accepted 17 Feb 1998, Published online: 09 Jul 2009

References

  • Tyers GFO, Mills P., Clark J., Cheesman M., Yeung-Lai-Wah J. A., Brownlee RR. Bipolar leads for use with permanently implantable cardiac pacing systems: a review of limitations of traditional and coaxial configurations and the development and testing of new conductor, insulation, and electrode design. J Invest Surg. 1997; 10: 1–15
  • Pinchuk L. A Review of the biostability and carcinogeni-city of polyurethanes in medicine and the new generation of ‘biostable’ polyurethanes. J Biomater Sci Polymer Ed. 1994; 6: 225–267
  • Gunatillake P. A., Meijs G. F., Brandwood A., Schindhelm K., Rizzardo E., McCarthy SJ. Long term in vivo stability of novel polyurethanes. Transactions of the 79th Annual Meeting Society for Biomaterial., Birmingham, ALUSA, 1993, 55
  • Meijs G., McCarthy S., Rizzardo E., Chen Y-C, Chatelier R., Brandwood A., Schindhelm K. Degradation of medical grade polyurethane elastomers: the effect of hydrogen peroxide. in vitro. J Biomed Mater Res. 1993; 27: 345–356
  • Zhao Q., Casas-Bejar J., Urbanski P., Stokes K. Glass wool-H2O2/CoCl2 test system forin vitro evaluation of biodegradative stress cracking in polyurethane elastomers. I of Biomed Mater Res. 1995; 29: 467–475
  • Stokes K., Urbanski P., Cobain K. New test methods for the evaluation of stress cracking and metal catalyzed oxidation of implanted polymers. Polyurethanes in Biomedical Engineering, H. Plank. Elsevier Science, New York 1987; 109–128
  • Phillips R., Frey M., Martin R. Longterm performance of polyurethane pacing leads: mechanisms of design related failures. PACE. 1986; 9: 1166–1172
  • Takahara A., Coury A. J., Hergenrother R. W., Cooper S. L. Effect of soft segment chemistry on the biostability of segmented polyurethanesin vitro oxidation. I Biomed Mater Res. 1991; 25: 341–356
  • Stokes K., Coury A., Urbanski P. Autooxidative degradation of implanted polyether polyurethane devices. I Biomater Appl. 1987; 4: 411–448
  • Stokes K., McVenes R., Anderson JM. Polyurethane elastomer biostability. J Biomat Appl. 1995; 9: 321–354
  • 1991, Medtronic Inc. Medtronic Pacing Leads, Progress and Performance.
  • , Medtronic Inc. Important Information about Metal lon Oxidation in Models 4004/4004M/4082 Pacemaker Leads. March 26, 1993
  • , Medtronic Inc. Important Patient Management Medtronic Models 4504/4504M/4582 Atrial Bipolar Leads. October 4, 1996
  • MacGregor D., Pinchuk L., Esquivel M., Martin J., Wilson G. Corethane® as a substitute for Pellethanea for pacemaker lead insulators. PACE. 1991; 14: 694
  • Szycher M., Reed A. Development of a biodurable polyurethane. Transactions of the 20th Annual Meeting Society for Biomateeetingname, Boston, MAUSA, 1994, 43
  • Pinchuk L., Kato Y. P., Eckstein M. L., Wilson G. J., MacGregor DC. Transactions of the 79th Annual Meeting Society for Biomaterial, Birmingham, ALUSA, 1993, 22
  • Szycher M., Reed A. M., Sciliano AA. In vivo testing of a biostable polyurethane. J Biomater Appl. 1991; 6: 110–130
  • Cobian K. Multiconductor versus conventional lead design: a discussion. Medtronic Technical Concept Paper. April, 1995
  • , ASTM D621, Standard Test Method for Deformation of Plastics Under Load. 1988.
  • Jacobs D., Fink A., Miller R., Anderson W., McVenes R., Lessar J., Cobain K., Staffanson D., Upton J., Burbick M. Anatomical and morphological evaluation of pacemaker lead compression. PACE. 1993; 16: 434–444
  • Dunkirk S. G., Gregg S. L., Duran L. W., Monfils J. D., Haapala J. E., Marcy J. A., Clapper D. L., Amos R. A., Guire PE. Photochemical coatings for the prevention of bacterial colonization. J Biomater Appl. 1991; 6: 131–156
  • Park K. D., Kim Y. S., Han D. K., Suh H. H., Choi K. S., Kim YH. Bacterial repellence on modified polyurethanes surfaces using PEG and heparin. Transactions of the 23th Annual Meeting Society Biomaterial. 1997, 111
  • Barbucci R., Albanese A., Magnani A., Tempesti F. Coating of commercially available materials with a new hep-ranizable material. J Biomed Mater Res. 1991; 25: 1259–1274
  • Gombotz W. R., Guanghi W., Horbett T. A., Hoffman A. S. Protein absorption to poly(ethylene oxide) surfaces. J Biomed Mater Res. 1991; 25: 1547–1562
  • Tang Y. W., Santerre J. P., Lablow R. S., Taylor D. G. Use of surface-modifying macromolecules to enhance the biostability of segmented polyurethanes. J Biomed Mater Res. 1997; 35: 371–381
  • Pinchuk L., Martin J. B., Esquivel M. C., MacGregor D. C. The use of silicone/polyurethane graft polymers as a means of eliminating surface cracking of polyurethane prostheses. J Biomater Appl. 1988; 3: 260–296
  • Ward R. S., White K. A., Gill R. S., Bertolet C. A. Surface activity and enhanced in vivo biostability of a segmented polyetherurethane with polydimethylsiloxane end groups. fifth World Biomaterials Congress. 1996, 818

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.