Performance of Subcutaneously Implanted Glucose Sensors: A Review

, , , &
Pages 163-174 | Received 12 May 1998, Accepted 13 May 1998, Published online: 09 Jul 2009

References

  • Diabetes Control and Complications Trial Research Group. The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. N Engl J Med. 1993; 329: 977–986
  • Eggins B. Biosensors: An Introduction. Wiley and Teubner, Chichester 1996
  • Black J. Biological Performance of Materials, Fundamentals of Biocompatibility 2nd ed. Marcel Dekker, New York 1992
  • Wilkins E, Atanasov P. Glucose monitoring: state of the art and future possibilities. Med Eng Phys. 1996; 18(4)273–288
  • Pickup J C, Thevenot D R. European achievements in sensor research dedicated to in vivo monitoring. Advances in Biosensors. JAI Press, London 1993; 201–225, supplement 1
  • Pickup J C. In vivo glucose monitoring: sense and sensorbility. Diabetes Care 1993; 16(2)535–539
  • Kyrolainen M, Rigsby P, Eddy S, Vadgama P. Bio-/ haemocompatibility: implications and outcomes for sensors?. Acta Anaesthesiol Scand 1995; 39(suppl. 104)55–60
  • Koudelka M, Rohner-Jeanrenaud F, Terrettaz J, Bobbioni-Harsch E, de Rooij N F, Jeanrenaud B. In vivo behaviour of hypodermically implanted microfabricated glucose sensors. Biosens Bioelectc 1991; 6: 31–36
  • Ward W K, Wilgus W, Troupe J E. Rapid detection of hyper-glycaemia by a subcutaneously implanted glucose sensor in the rat. Biosens Bioelectr. 1994; 9: 423–428
  • Updike S J, Shults M C, Rhodes R K, Gilligan B J, Luebow J O, von Heimburg D. Enzymatic glucose sensors: improved long-term performance in vitro and in vivo. ASAIO J 1994; 40: 157–163
  • Gilligan B J, Shults M C, Rhodes R K, Updike S J. Evaluation of a subcutaneous glucose sensor out to 3 months in a dog model. Diabetes Care 1994; 17: 882–887
  • Shults M C, Rhodes R K, Updike S J, Gilligan B J. Reining WN. A telemetry-instrumentation system for monitoring multiple subcutaneously implanted glucose sensors. IEEE Trans Biomed Eng. 1994; 41: 937–942
  • Wilkins E, Atanasov P. Integrated implantable device for long-term glucose monitoring. Biosens Bioelectr. 1995; 10: 485–494
  • Moussy F, Harrison D J, Rajotte R V. A miniaturized Nafion-based glucose sensor: in vitro and in vivo evaluation in dogs. Int J Artif Organs 1994; 17: 88–94
  • Moussy F, Harrison D J, O'Brein D W, Rajotte R V. Performance of subcutaneously implanted needle-type glucose sensors employing a novel trilayer coating. Anal Chem. 1993; 65: 2072–2077
  • Moussy F, Jakeway S, Harrison J D, Rajotte R V. In vitro and in vivo performance and lifetime of perfluorinated ionomercoated glucose sensors after high-temperature curing. Anal Chem. 1994; 66: 3882–3888
  • Ertefai S, Gough D A. Physiological preparation for studying the response of subcutaneously implanted glucose and oxygen sensors. J Biomed Eng. 1989; 11: 362–368
  • Cammann K. Implantable electrochemical glucose sensors: state of the art. Horm Metab Res Suppl. 1988; 20: 4–8
  • Gough D A, Armour J C. Development of the implantable glucose sensor: what are the prospects and why is it taking so long?. Diabetes. 1995; 44: 1005–1009
  • Wilkins E S. Towards implantable glucose sensors: a review. J Biomed Eng. 1989; 11: 354–361
  • Fischer U. Fundamentals of glucose sensors. Diabetic Med. 1991; 8: 309–321
  • Kerner W, Kiwit M, Linke B, Keck F, Zier H, Pfeiffer E F. The function of a hydrogen peroxide-detecting electroenzymatic glucose sensor is markedly impaired in human subcutaneous tissue and plasma. Biosens Bioelectc 1993; 8: 473–482
  • Fraser D M. Biosensors in the Body Continuous In Vivo Monitoring. John Wiley & Sons, Chichester 1997
  • Abel P, Muller A, Fischer U. Experience with an implantable glucosc sensor as a prerequisite of an artificial beta cell. Biomed Biochim Acta. 1984; 43: 577–584
  • Abel P, Fischer U, Brunstein E, Ertle R. The GOD-H2O2-electrode as an approach to implantable glucose sensors. Horm Metab Res Suppl. 1988; 20: 26–29
  • Shichiri M, Kawamori R, Yamasaki Y. The development of artificial endocrine pancreas. Med Prog Technol. 1987; 12: 39–50
  • Rebrin K, Fischer U, von Woedtke T, Abel P, Brunstein E. Automated feedback control of subcutaneous glucose concentration in diabetic dogs. Diabetologia. 1989; 32: 573–576
  • Pickup J C, Shaw G W, Claremont D J. In vivo molecular sensing in diabetes mellitus: an implantable glucose sensor with direct electron transfer. Diabetologia. 1989; 32: 213–217
  • Moatti-Sirat D, Capron F, Poitout V, Reach G, Bindra D S, Zhang Y, Wilson G S, Thevenot-DR. Towards continuous glucose monitoring: in vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissue. Diabetologia. 1992; 35: 224–230
  • Moatti-Sirat D, Vehlo G, Reach G. Evaluating in vitro and in vivo the interference of ascorbate and acetaminophen on glucose detection by a needle-type glucose sensor. Biosens Bioelectr 1992; 7: 345–352
  • Moatti-Sirat D, Poitout V, Thome V, Gangnerau M N, Zhang Y, Hu Y, Wilson G S, Lemonnier F, Klein J C, Reach G. Reduction of acetaminophen interference in glucose sensors by a composite Nafion membrane: demonstration in rats and man. Diabetologia. 1994; 37: 610–616
  • Poitout V, Moatti-Sirat D, Reach G, Wilson G S, Lemonnier F, Klein J C. A glucose monitoring system for on line estimation in man of blood glucose concentration using a miniaturized glucose sensor implanted in the subcutaneous tissue and a wearable control unit. Diabetologia 1993; 36: 658–663
  • Poitout V, Moatti D, Vehlo G, Reach G, Sternberg R, Thevenot D R, Bindra D S, Zhang Y, Wilson G S. In vitro and in vivo evaluation in dogs of a miniaturized glucose sensor. ASAIO Trans. 1991; 37: M298–M300
  • Poitout V, Moatti-Sirat D, Reach G. Calibration in dogs of a subcutaneous miniaturized glucose sensor using a glucose meter for blood glucose determination. Biosens Bioelectr 1992; 7: 587–592
  • Johnson K W, Mastrototaro J J, Howey D C, Brunelle R L, Burden-Brady P L, Bryan N A, Andrew C C, Rowe H M, Allen D J, Noffke B W, Mc Mahan W C, Morff R J, Lipson D, Nevin R S. In vivo evaluation of an electroenzymatic glucose sensor implanted in subcutaneous tissue. Biosens Bioelectr. 1992; 7: 709–714
  • Von Woedtke X, Fischer U, Brunstein E, Rebrin K, Abel P. Implantable glucose sensors: comparison between in vitro and in vivo kinetics. Int J Artif Organs 1991; 14: 473–481
  • Velho G, Froguel P, Thevenot D R, Reach G. In vivo calibration of a subcutaneous glucose sensor for determination of subcutaneous glucose kinetics. Diabetes Nutr Metab. 1988; 3: 227–233
  • Pfeiffer E F, Meyerhoff C, Bischof F, Keck F S, Kerner W. On line continuous monitoring of subcutaneous tissue glucose is feasible by combining portable glucose sensor with microdialysis. Horm Metab Res. 1993; 25: 121–124
  • Koudelka M, Rohner-Jeanrenaud F, Terrettaz J, Bobbioni-Harsch E, de Rooij N F, Jeanrenaud B. In vivo response of microfabricated glucose sensors to glycaemia changes in normal rats. Biomed Biochim Acta. 1989; 48: 953–956
  • Koudelka M, Rohner-Jeanrenaud F, Terrettaz J, Bobbioni-Harsch E, de Rooij N F, Jeanrenaud B. In vivo behaviour of hypodermically implanted microfabricated glucose sensors. Biosens Bioelectr 1991; 6: 31–36
  • Bobbioni-Harsch E, Rohner-Jeanrenaud F, Koudelka M, de Rooij N, Jeanrenaud B. Lifespan of subcutaneous glucose sensors and their performances during glycaemia changes in rats. J Biomed Eng. 1993; 15: 457–463
  • Sternberg R, Barrau M B, Gangiotti L, Thevenot D R, Bindra D S, Wilson G S, Vehlo G, Froguel P, Reach G. Study and development of multilayer needle-type enzyme-based glucose microsensors. Biosenson. 1988; 4: 27–40
  • Velho G, Froguel P, Thevenot D R, Reach G. Strategies for calibrating a subcutaneous glucose sensor. Biomed Biochim Acta. 1989; 48: 957–964
  • Von Woedtke X, Rebrin K, Fischer U, Abel P, Wilke W, Vogt L, Albrecht G. In situ calibration of implanted electrochemical glucose sensors. Biomed Biochim Acta. 1989; 48: 943–952
  • Park J B, Lakes R S. Biomaterials, An Introduction. 2nd ed. Plenum Press, New York 1992
  • Williams D F. Tissue-biomaterial interactions. J Mater Sci. 1987; 22: 3421–3445
  • Spector M, Cease C, Tong-Li X. The local tissue response to biomaterials. Crit Rev Biocompatibility 1989; 5(3)269–295
  • Remes A, Williams D F. Immune response in biocompatibility. Biomaterials 1992; 13(11)731–743
  • Brash J L, Wojciechowski P W. Interfacial Phenomena and Bioproducts. Marcel Dekker, New York 1996
  • Horbett T A, Brash J L. Proteins at Interfaces: fundamentals and Applications. American Chemical Society, Washington, DC 1995
  • Shichiri M, Kawamori R, Hakui N, Asakawa N, Yamasaki Y, Abe H. The development of wearable-type artificial endocrine pancreas and its usefulness in glycaemic control of human diabetes mellitus. Biomed Biochim Acta. 1984; 5: 561–568
  • Shichiri M, Yamasaki Y, Nao K, Sekiya M, Ueda N. In vivo characteristics of needle-type glucose sensor: measurements of subcutaneous glucose concentrations in human volunteers. Horm Metab Respondent Suppl. 1988; 20: 17–20
  • Muller A, Abel P, Fischer U. Continuous monitoring of subcutaneous glucose concentration using implanted enzyme electrodes. Biomed Biochim Acta. 1986; 45: 769–777
  • Brunstein E, Abel P, Gens A, Eich K, von Woedtke T. Preparation and validation of implantable electrodes for the measurement of oxygen and glucose. Biomed Biochim Acta. 1989; 48: 911–917
  • Rigby G P, Crump P, Vadgama P. Open flow microperfusion: approach to in vivo glucose monitoring. Med Biol Eng Comput. 1995; 33: 231–234
  • Rigby G P, Crump P, Vadgama P. Stabilized needle electrode system for in vivo glucose monitoring based on open flow microperfusion. Analyst. 1996; 121: 871–875
  • Labow R S, Erfle D J, Santerre J P. Neutrophil-mediated degradation of segmented polyurethanes. Biomaterials 1995; 16: 51–59
  • Wilson R, Turner A PF. Glucose oxidase: an ideal enzyme. Biosens Bioelectr 1992; 7: 165–185
  • Rebrin K, Fischer U, von Dorsche Hahn H, von Woetke T, Abel P, Brunstein E. Subcutaneous glucose monitoring by means of electrochemical sensors: fiction or reality?. J Biomed Eng 1992; 14: 33–40
  • Updike S J, Shults M, Ekman B. Implanting the glucose enzyme electrode: problems, progress, and alternative solutions. Diabetes Care 1982; 5(3)207–212
  • Fischer U, Hidde A, Herrmann S, von Woedtke X, Rebrin K, Abel P. Oxygen tension at the subcutaneous implantation site of glucose sensors. Biomed Biochim Acta 1989; 48: 965–971
  • Zhang Y, Wilson G S. In vitro and in vivo evaluation of oxygen effects on a glucose oxidase based implantable glucose sensor. Anal Chim Acta. 1993; 281: 513–520
  • Bessman S P, Thomas L J, Koijma H, Sayler D F, Layne E C. The implantation of a closed-loop artificial beta cell in dogs. Trans Am Soc Artif Intern Organs 1981; 27: 7–17
  • Reach G, Feijen J, Alcock A. BIOMED concerted action chemical sensors for in vivo monitoring. The biocompatibility issue. Biosens Bioelectr 1994; 9(6)21–28
  • Woodward S C. How fibroblasts and giant cells encapsulate implants: considerations in design of glucose sensors. Diabetes Care 1982; 5: 278–281
  • Sharkawy A A, Klitzman B, Truskey G A, Reichert W M. Engineering the tissue which encapsulates subcutaneous implants. 1. Diffusion properties. J Biomed Mater Res. 1997; 37: 401–412
  • Chang K W, Aisenberg S, Soeldner J S, Hiebert J M. Validation and bioengineering aspects of an implantable glucose sensor. Trans Am Soc Artif Intern Organs 1973; 19: 352–360
  • Shichiri M, Yamasaki Y, Kawamori R, Hakui N. Wearable artificial endocrine pancreas with needle-type glucose sensor. lancet. 1982; 20: 1129–1130
  • Shichiri M, Asakawa N, Yamasaki Y, Kawamori R, Abe H. Telemetry glucose monitoring device with needle-type glucose sensor: a useful tool for blood glucose monitoring in diabetic individuals. Diabetes Care 1986; 9: 298–301
  • Shichiri M, Kawamori R, Goriya Y, Yamasaki Y, Nomura M, Hakui N, Abe H. Glycaemic control in pancreatectomized dogs with a wearable artificial endocrine pancreas. Diabetologia. 1983; 24: 179–184
  • Nishida K, Sakakida M, Ichinose K, Uemura T, Uehara M, Kajiwara K, Miyata T, Shichiri M, Ishihara K, Nakabayashi N. Development of a ferrocene-mediated needle-type glucose sensor covered with newly designed biocompatible membrane, 2-methacryloyloxyethyl phosphorylcholine-co-n-butyl methacrylate. Med Prog Technol. 1995; 21: 91–103
  • Claremont D J, Sambrook I E, Penton C, Pickup J C. Subcutaneous implantation of a ferrocene-mediated glucose sensor in pigs. Diabetologia. 1986; 29: 817–821
  • Pickup J C, Claremont D J, Shaw G W. Responses and calibration of amperometric glucose sensors implanted in the subcutaneous tissue of man. Acta Diabetologia. 1993; 30: 143–148
  • Shichiri M, Kawamori R, Hakui N, Yamasaki Y, Abe H. Closed-loop glycaemic control with a wearable artificial endocrine pancreas: variations in daily insulin requirements to glycaemic response. Diabetes. 1984; 33: 1200–1202
  • Bruckel J, Kerner W, Zier H, Steinbach G, Pfeiffer E F. In vivo measurement of subcutaneous glucose concentrations with an enzymatic glucose sensor and a wick method. Klin Wochenschr. 1989; 67: 491–495
  • Fischer U, Ertle R, Abel P, Brunstein E, von Dorsche Hahn H, Freyse E J. Assessment of subcutaneous glucose concentration: validation of the wick technique as a reference for implanted electrochemical sensors in normal and diabetic dogs. Diabetologia. 1987; 30: 940–945
  • Fischer U, Ertle R, Rebrin K, Freyse E J. Wick technique: reference method for implanted glucose sensors. Artif Organs 1989; 13: 453–458
  • Vehlo G, Froguel P, Sternberg R, Thevenot D R, Reach G. In vitro and in vivo stability of electrode potentials in needle-type glucose sensors. Influence of needle material. Diabetes. 1989; 38: 164–171
  • Mc Kean B D, Gough D A. A telemetry-instrumentation system for chronically implanted glucose and oxygen sensors. IEEE Trans Biomed Eng. 1988; 35: 526–532
  • Matthews D R, Bown E, Beck T W, Plotkin E, Lock L, Gosden E, Wickham M. An amperometric needle-type glucose sensor tested in rats and man. Diabetic Med. 1988; 5: 248–252
  • Quinn C P, Pishko M V, Schmidtke D W, Ishikawa M, Wagner J G, Raskin P, Hubbell J A, Heller A. Kinetics of glucose delivery to subcutaneous tissue in rats measured with 0.3-mm amperometric microsensors. Am J Physiol. 1995; 269: E155–E161
  • Linke B, Kerner W, Kiwit M, Pishko M, Heller A. Amperometric biosensor for in vivo glucose sensing based on glucose oxidase immobilized in a redox hydrogel. Biosens Bioelectr 1994; 9: 151–158
  • Clark L C, Jr, Duggan C A. Implanted electroenzymatic glucose sensors. Diabetes Care 1982; 5(3)174–180

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.