35
Views
9
CrossRef citations to date
0
Altmetric
Original Article

Long-Term Evaluation of Orthotopically Implanted Stentless Bioprosthetic Aortic Valves in Juvenile Sheep

, , , &
Pages 175-183 | Received 06 Jan 1998, Accepted 24 Apr 1998, Published online: 09 Jul 2009

References

  • Fisher J, Davies G A. Buckling in bioprosthetic valves. Ann Thorac Surg. 1989; 48: 147–148
  • Ishihara T, Ferrans V J, Boyce S W, et al. Structure and classification of cuspal tears and perforations in porcine bioprosthetic cardiac valves implanted in patients. Am J Cardiol. 1981; 48: 665–677
  • Thubrikar M J, Deck J D, Aouad J, Nolan S P. Role of mechanical stress in calcification of aortic bioprosthetic valves. J Thorac Cardiovasc Surg. 1983; 86: 115–125
  • Vesely I, Boughner D R, Song T. Tissue Buckling as a mechanism of bioprosthetic valve failure. Ann Thorac Surg. 1988; 46: 302–308
  • Angell W W, Angell J D, Oury J H, et al. Long-term follow-up of viable frozen aortic homografts. J Thorac Cardiovasc Surg. 1987; 93: 815
  • Drury P J, Dobrin J, Bodnar E, . Distribution of flexibility in the porcine aortic root and in cardiac support frames. Biologic Bioprosthetic Valve, E Bodnar, M Yacoub, et al. Yorke Medical, New York 1986; 580
  • Vesely I, Boughner D R. A comparison of the bending behavior of fresh and glutaraldehyde treated porcine aortic leaflets. Circulation 1986; 74: 339
  • David T E, Feindel C M, Bos J, et al. Aortic valve replacement with a stentless porcine aortic valve: a six-year experience. J Thorac Cardiovasc Surg. 1994; 108: 1030–1036
  • Sung H W, Le T N, Kingsbury C J, et al. In vitro pulsatile flow evaluation of a stentless porcine aortic bioprosthesis. ASAIOJ 1995; 41: 89–94
  • Walther T, Falk V, Autsch R, et al. Hemodynamic assessment of the stentless Toronto SPV bioprosthesis by echocardiography. J Heart Valve Dis. 1994; 3: 657–665
  • Irwin E, Lang G, Clack R, St Cyr J, Runge W, Foker J, Bianco R W. Long-term evaluation of prosthetic mitral valves in sheep. J Invest Surg. 1993; 6: 133–141
  • Hazekamp M G, Coffin Y A, Huysmans H A. The value of the stentless biovalve prosthesis: an experimental study. furl Cardio-Thoracic Surg. 1993; 7: 514–519
  • David T E, Ropchan G C, Butany J W. Aortic valve replacement with stentless porcine bioprostheses. J Cardiac Surg. 1988; 3: 501–505
  • Brown W M, Jay J L, Gott J P, et al. Placement of aortic valve bioprostheses in sheep via a left thoracotomy: implantation of stentless porcine heterografts. Trans Am Soc Artif Intern Organs 1991; 37: M445–M446
  • Schoen F J, Levy R J, Hilbert S L, Bianco R W. Antimineralization treatments for bioprosthetic heart valves: assessment of efficacy and safety. I Thorac Cardiovasc Surg. 1992; 104: 1285–1288
  • Braunwald N S, Bonchek L I. Prevention of thrombus formation on rigid prosthetic heart valves by the in-growth of autogenous tissue. J Thorac Cardiovasc Surg 1976; 54: 630–638
  • Gallo I, Frater R WM. Experimental atrioventricular bioprosthetic valve insertion: a simple and successful technique. Thorac Cardiovasc Surg. 1983; 331: 288–290
  • Bjork V O, Sternlieb J. Artificial heart valve testing in goats. Scand J Thor Cardiovasc Surg. 1986; 20: 97–102
  • Swan H, Meagher M. Technical aspects of cardiac transplantation in the pig. J Thorac Cardiovasc Surg. 1971; 61: 710–723
  • Hasenkam J M, Ostergaard J H, Pederson E M, et al. A model for acute haemodynamic studies in the ascending aorta in pigs. Cardiovasc Res. 1988; 22: 464–471
  • Swan H, Meagher M. Total body bypass in miniature pigs. J Thorac Cardiovasc Surg. 1971; 61: 956–967
  • Sawyer D C. Factors governing choice of animals for chronic instrumentation studies. Chronically Implanted Cardiovascular Instrumentation, E P McCutcheon. Academic Press, New York 1973; 195–202
  • Bianco R W, St Cyr J A, Schneider J R, et al. Canine model for long-term evaluation of prosthetic mitral valves. J Surg Res. 1986; 41: 134–140
  • Farer L S. Mycobacterium tuberculosis: bacteriology, epidemiology and treatment. Principles and Practice of Infectious Disease, G Mandell. Wiley, New York 1979; 106
  • Tabor E, Gerety R J, Drucker J A, et al. Transmission of non-A, non-B hepatitis from man to chimpanzee. Lancet. 1978; 1: 463
  • Aasen A O, Resch F, Semb B J, et al. Development of a canine model for long-term studies after mitral valve replacement with the HallKaster prosthesis. fur Surg Res. 1980; 12: 199–207
  • Jones R D, Cross F S, Akao M. Bacteremia and thrombus on prosthetic heart valves in dogs. Circulation 1969; 39(Suppl. 1)253–256
  • Semb B K, Aasen A O, Woxholt G, et al. In vivo haemodynamic evalution of the Hall-Kaster central flow prosthetic valve. Scand J Clin Lab Invest. 1979; 39: 731–736
  • Barnhart G R, Jones M, Lshihara T, et al. Bioprosthetic valvular failure: clinical and pathological observations in an experimental animal model. J Thorac Cardiovasc Surg. 1982; 83: 618–631
  • Tillman P, Carson S N, Talken L. Platelet function and coagulation parameters in sheep during experimental vascular surgery. Lab Anim Sci. 1981; 31: 263–267
  • Sands M P, Rittenhouse E A, Mohri H, Merendino A. An anatomical comparison of human, pig, calf, and sheep aortic valves. Ann Thorac Surg. 1969; 8: 407–414
  • Barnhart G R, Jones M, Ishihara T, et al. Degeneration and calcification of bioprosthetic cardiac valves: bioprosthetic tricuspid valve implantation in sheep. Am J Pathol. 1982; 106: 136–139
  • Jones M, Barnhart G R, Chavez A M, . Experimental evaluation of bioprosthetic valves implanted in sheep. Cardiac Bioprostheses, L H Cohn, V Calluci, et al. Yorke Medical, New York 1982; 275–292
  • Barak J, Einav S, Tadmor A, et al. The effect of colloid osmotic pressure on the survival of sheep following cardiac surgery. Int J Artif Organs 1989; 12: 47–50
  • Cremer J, Boetel C, Fredow G, et al. Radiographic assessment of structural defects in Bjork—Shiley convexo-concave prostheses. Eur J Cardio-Thoracic Surg. 1995; 9: 373–377
  • Shiota T, Jones M, Valdes-Cruz L M, et al. Color flow Doppler determination of transmitral flow and orifice area in mitral stenosis: experimental evaluation of the proximal flow-convergence method. Am Heart J. 1995; 129: 114–123
  • Bianco R W, Phillips R, Mrachek J, Witson J. Feasibility evaluation of a new pericardial bioprosthesis with dye mediated photo-oxidized bovine pericardial tissue. J Heart Valve Dis. 1996; 5: 317–322
  • Gott J P, Pan-Chih Dorsey L MA, et al. Calcification of porcine valves: a successful new method of anti-mineralization. Ann Thorac Surg. 1992; 53: 207–216
  • Liao K, Gong G, Hoffman D, et al. Spontaneous host endothelial growth on bioprosthetic valves and its relation to calcification. Eur J Cardio-Thoracic Surg. 1993; 7: 591–596
  • Schoen F J, Hirsch D, Bianco R W, Levy R J. Onset and progression of calcification in porcine aortic bioprosthetic valves implanted as orthotopic mitral valve replacements in juvenile sheep. J Thorac Cardiovasc Surg. 1995; 108: 880–887
  • Vyavahare N, Hirsch D, Lerner E, et al. Prevention of bioprosthetic heart valve calcification by ethanol preincubation: efficacy and mechanisms. Circulation 1997; 95: 479–488
  • Angell W W, Oury J H, Lamberti J J, Koziol J. Durability of the viable aortic allograft. J Thorac Cardiovasc Surg. 1989; 98: 48–56
  • Walther T, Falk V, Diegeler A, et al. Stentless valve replacement in the small aortic root. Cardiovasc Surg. 1997; 5: 229–234

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.