References
- Baron P. A. Aerosol photometers for respirable dust measurements. Supplement to NIOSH manual of analytical methods, 3rd ed. Cincinnati, OH 1985
- BGI, Inc. WDF-II operating instructions, 2nd ed. BGI, Inc, Waltham, MA 1989
- Box G. E. P., Jenkins G. M. Time series analysis: Forecasting and control. Holden-Day, San Francisco 1970; 123
- Cheng Y. -S., Barr E. B., Benson J. M., Damon E. G., Medinsky M. A., Hobbs C. H., Goehl T. J. Evaluation of a real-time aerosol monitor (RAM-S) for inhalation studies. Fundam. Appl. Toxicol. 1988; 10: 321–328
- Coggins C. R., Ayers P. H., Mosberg A. T., Burger G. T., Sagartz J. W., Hayes A. W. Comparative inhalation study in rats, using a second prototype of a cigarette that heats rather than burns tobacco. Inhal. Toxicol. 1989; 1: 197–226
- Collins G. F. Measurement of variation in output rate from aerosol generators. J. Aerosol Sci. 1975; 6: 169–172
- Crider W. L., Landis D. A., Weaver F. H. Computer-controlled human exposure facilities utilizing water-soluble aerosols. Generation of aerosols and facilities for exposure experiments, K. Willeke. Ann Arbor Science, Ann Arbor, MI 1980; 493–515
- Davis J. W., Irwin V. C. A dry dust generator system for animal exposures at controlled concentrations. Am. Ind. Hyg. Assoc. J. 1982; 43: 704–711
- Gressel M. G., Heitbrink W. A., McGlothlin J. D., Fischbach T. J. Real-time, integrated, and ergonomic analysis of dust exposure during manual materials handling. Appl. Ind. Hyg. 1987; 2: 108–113
- Hemenway D. R., Boudreau K., Miller J. Retrofitting of a Wright dustfeed. Am. Ind. Hyg. Assoc. J. 1986; 47: 301–307
- Hemenway D. R., MacAskill S. M. Design, development and test results of a horizontal flow inhalation toxicology facility. Am. Ind. Hyg. Assoc. J. 1982; 43: 874–879
- Hinds W. C. Dry-dispersion aerosol generators. Generation of aerosols and facilities for exposure experiments, K. Willeke. Ann Arbor Science, Ann Arbor, MI 1980; 171–187
- Hirano S. Automatic control of aerosol concentration in exposure chambers. Am. Ind. Hyg. Assoc. J. 1987; 48: 972–6
- Page S. J., Jankowski R. A. Correlations between measurements with RAM-1 and gravimetric samplers on longwall shearer faces. Am. Ind. Hyg. Assoc. J. 1984; 45: 610–616
- Phalen R. F. Inhalation studies: Foundations and techniques. CRC Press, Boca Raton, FL 1984; 24–27
- Schuurmans C. J. E., Coops A. J. Seasonal mean temperatures in Europe and their interannual variability. Monthly Weather Rev. 1984; 112: 1218–1225
- Smith J. P. Use of scattered light particulate monitors with a foundry air recirculation system. Appl. Ind. Hyg. 1987; 2: 74–78
- Smith J. P., Baron P. A., Murdock D. J. Response characteristics of scattered light aerosol sensors used for control monitoring. Am. Ind. Hyg. Assoc. J. 1987; 48: 219–229
- Willeke K., Baron P. A. Sampling and interpretation errors in aerosol monitoring. Am. Ind. Hyg. Assoc. J. 1990; 51: 160–168
- Willeke K., Degarmo S. J. Passive versus active aerosol monitoring. Appl. Ind. Hyg. 1988; 3: 263–266
- Wright B. M. A new dust-feed mechanism. J. Sci. Instrum. 1950; 27: 12–15