References
- Chan LM, Westhoff CL. Tubal sterilization trends in the United States. Fertil Steril 2010;94:1–6
- Peterson HB. Sterilization. Obstet Gynecol 2008;111:189–203
- Chapman L, Magos A. Currently available devices for female sterilization. Expert Rev Med Devices 2005;2:623–34
- Hurskainen R, Hovi SL, Gissler M, et al. Hysteroscopic tubal sterilization: a systematic review of the Essure system. Fertil Steril 2010;94:16–19
- Duffy S, Marsh F, Rogerson L, et al. Female sterilisation: a cohort controlled comparative study of Essure versus laparoscopic sterilisation. BJOG 2005;112:1522–8
- Miño M, Arjona JE, Cordon J, et al. Success rate and patient satisfaction with the Essure sterilisation in an outpatient setting: a prospective study of 857 women. BJOG 2007;114:763–6
- Arjona JE, Miño M, Cordon J, et al. Satisfaction and tolerance with office hysteroscopic tubal sterilization. Fertil Steril 2008;90:1182–6
- Bettocchi S, Selvaggi L. A vaginoscopic approach to reduce the pain of office hysteroscopy. J Am Assoc Gynecol Laparosc 1997;4:255–8
- Rogerson L, Hudson H, Duffy S. UK Experience using the ESSURE micro-insert for hysteroscopic sterilisation. Rev Gynaecol Pract 2003;3:1–4
- Essure ESS305 Instructions for Use. Conceptus Inc., Mountain View, CA. Available from: www.essuremd.com/App_Themes/BaseTheme/PDFs/Link%20Essure%20IFU.pdf [last accessed 18 March 2013]
- Arjona JE, Miño M, Cordon J, García-Oliveros I. Essure: the minimally invasive alternative to the laparoscopic tubal sterilization. Obstet Gynecol 2005;105:14S
- Sinha D, Kalathy V, Gupta JK, Clark TJ. The feasibility, success and patient satisfaction associated with outpatient hysteroscopic sterilisation. BJOG 2007;114:676–83
- Levie MD, Chudnoff SG. Prospective analysis of office-based hysteroscopic sterilization. J Minim Invasive Gynecol 2006;13:98–101
- Panel P, Grosdemouge I. Predictive factors of Essure implant placement failure: prospective, multicenter study of 495 patients. Fertil Steril 2010;93:29–34
- Connor VF. Essure: a review six years later. J Minim Invasive Gynecol 2009;16:282–90
- Veersema S, Vleugels M, Moolenaar L, et al. Unintended pregnancies after Essure sterilization in the Netherlands. Fertil Steril 2010;93:35–8
- Moses A, Burgis J, Bacon J, Risinger J. Pregnancy after Essure placement: report of two cases. Fertil Steril 2008;89:724e9–11
- Kartighasu K, Garry R, Hart R. Case report of failed tubal occlusion using Essure™ pbc (permanent birth control) hysteroscopic sterilisation procedure. Aus New Zealand J Obstet Gynaecol 2006;46:365–7
- Trussell J. Contraceptive failure in the United States. Contraception 2004;70:89–96
- Peterson HB, et al. The risk of pregnancy after tubal sterilization: findings from the U.S. collaborative review of sterilization. Am J Obstet Gynecol 1996;174:1161–8
- Palmer SN, Greenberg JA. Transcervical sterilization: a comparison of Essure® permanent birth control system and Adiana® permanent contraception system. Rev Obstet Gynecol 2009;2:84–92
- Adiana Permanent Birth Control System Instruction for Use. Hologic Inc., Marlborough, MA; 2009
- Arjona JE, Serrano JJ, Povedano B, et al. Unintended pregnancy after long-term Essure microinserts placement. Fertil Steril 2010;94:2793–5