81
Views
3
CrossRef citations to date
0
Altmetric
Research Article

Direct electrochemistry and electrocatalysis of hemoglobin on polypyrrole-Fe3O4/dodecyltrimethylammonium bromide-modified carbon paste electrode and its biosensing for hydrogen peroxide

, , &
Pages 313-322 | Received 23 Oct 2012, Accepted 21 Oct 2013, Published online: 25 Nov 2013

References

  • Cai CX, Chen J. 2004. Direct electron transfer and bioelectrocatalysis of hemoglobin at a carbon nanotube electrode. Anal Biochem 325:285–292.
  • Chang MCY, Pralle A, Isacoff EY, Chang CJ. 2004. A selective, cell-permeable optical probe for hydrogen peroxide in living cells. J Am Chem Soc 126:15392–15393.
  • Charradi K, Gondran C, Amara A, Prevot V, Mousty C. 2009. H2O2 determination at iron-rich clay modified electrodes. Electrochim Acta 54:4237–4244.
  • Chen Y, Wang FB, Guo LR, Zheng LM, Xia XH. 2009. Functional interface of ferric ion immobilized on phosphonic acid terminated self-assembled monolayers on a Au electrode for detection of hydrogen peroxide. J Phys Chem C 113:3746–3750.
  • Chen L, Lu GX. 2006. Direct electrochemistry and electrocatalysis of hybrid film assembled by polyelectrolyte–surfactant polymer, carbon nanotubes and hemoglobin. J Electroanal Chem 597:51–59.
  • Cui X, Liu G, Lin Y. 2005. Biosensors based on carbon nanotubes/nickel hexacyanoferrate/glucose oxidase nanocomposites. J Biomed Nanotechnol 1:320–327.
  • Fan H, Pan ZQ, Gu HY. 2010. The self-assembly, characterization and application of hemoglobin immobilized on Fe3O4@Pt core-shell nanoparticles. Microchim Acta 168:239–244.
  • Feng JJ, Xu JJ, Chen HY. 2006. Direct electron transfer and electrocatalysis of hemoglobin adsorbed onto electrodeposited mesoporous tungsten oxide. Electrochem Commun 8:77–82.
  • Hurdis EC, Romeyn H Jr. 1954. Accuracy of determination of hydrogen peroxide by cerate oxidimetry. Anal Chem 26: 320–325.
  • Jia NQ, Lian Q, Wang ZY, Shen HB. 2009. A hydrogen peroxide biosensor based on direct electrochemistry of hemoglobin incorporated in PEO–PPO–PEO triblock copolymer film. Sens. Actuators B Chem 137:230–234.
  • Jian FF, Qiao YB, Zhuang RR. 2007. Direct electrochemistry of hemoglobin in TATP film: Application in biological sensor. Sens Actuators B Chem 124:413–420.
  • Kamin RA, Wilson GS. 1980. Rotating ring-disk enzyme electrode for biocatalysis kinetic studies and characterization of the immobilized enzyme layer. Anal Chem 52:1198–1205.
  • Katz E, Weizmann Y, Willner I. 2005. Magnetoswitchable reactions of DNA monolayers on electrodes: gating the processes by hydrophobic magnetic nanoparticles. J Am Chem Soc 127:9191–9200.
  • Kong YT, Boopathi M, Shim YB. 2003. Direct electrochemistry of horseradish peroxidase bonded on a conducting polymer modified glassy carbon electrode. Biosens Bioelectron 19: 227–232.
  • Laviron E. 1974. Adsorption, autoinhibition and autocatalysis in polarography and in linear potential sweep voltammetry. Electroanal Chem 52:355–393.
  • Laviron E. 1979a. The use of linear potential sweep voltammetry and of a.c. voltammetry for the study of the surface electrochemical reaction of strongly adsorbed systems and of redox modified electrodes. J Electroanal Chem 100:263–270.
  • Laviron E. 1979b. General expression of the linear potential sweep voltammogram in the case of diffusionless electrochemical systems. J Electroanal Chem 101:19–28.
  • Li YP, Cao HB, Zhang Y. 2005. Direct electrochemistry of hemoglobin immobilized on carbon paste electrode modified by carbon nanotubes. Acta Phys Chim Sin 21:187–191.
  • Liu KP, Zhang JJ, Yang GH, Wang CM, Zhu JJ. 2010. Direct electrochemistry and electrocatalysis of hemoglobin based on poly(diallyldimethylammonium chloride) functionalized grapheme sheets/room temperature ionic liquid composite film. Electrochem Commun 12:402–405.
  • Liu MC, Zhao GH, Zhao KJ, Tong XL, Tang YT. 2009. Direct electrochemistry of hemoglobin at vertically-aligned self- doping TiO2 nanotubes: a mediator-free and biomolecule- substantive electrochemical interface. Electrochem Commun 11:1397–1400.
  • Liu SQ, Peng L, Yang XD, Wu YF, He L. 2008. Electrochemistry of cytochrome P450 enzyme on nanoparticle-containing membrane-coated electrode and its applications for drug sensing. Anal Biochem 375:209–216.
  • Liu SQ, Ju HX. 2003. Electrocatalysis via direct electrochemistry of myoglobin immobilized on colloidal gold nanoparticles. Electroanalysis 15:1488–1493.
  • Liu SQ, Ju HX. 2002. Renewable reagentless hydrogen peroxide sensor based on direct electron transfer of horseradish peroxidase immobilized on colloidal gold-modified electrode. Anal Biochem 307:110–116.
  • Lu Q, Zhou T, Hu SS. 2007. Direct electrochemistry of hemoglobin in PHEA and its catalysis to H2O2. Biosens Bioelectron 22:899–904.
  • Lu XB, Zhou JH, Lu W, Liu Q, Li JH. 2008. Carbon nanofiber-based composites for the construction of mediator-free biosensors. Biosens Bioelectron 23:1236–1243.
  • Liu Y, Han T, Chen C, Bao N, Yu CM, Gu HY. 2011. A novel platform of hemoglobin on core shell structurally Fe3O4@Au nanoparticles and its direct electrochemistry. Electrochim Acta 56:3238–3247.
  • Matsubara C, Kawamoto N, Takamura K. 1992. Oxo[5, 10, 15, 20-tetra(4-pyridyl)porphyrinato]titanium(IV): an ultra-high sensitivity spectrophotometric reagent for hydrogen peroxide. Analyst 117:1781–1784.
  • Mosbach K, Anderson L. 1977. Magnetic ferrofluids for preparation of magnetic polymers and their application in affinity chromatography. Nature 270:259–261.
  • Safavi A, Maleki N, Moradlou O, Sorouri M. 2008. Direct electrochemistry of hemoglobin and its electrocatalytic effect based on its direct immobilization on carbon ionic liquid electrode. Electrochem Commun 10:420–423.
  • Salimi A, Hallaj R, Soltanian S. 2007. Immobilization of hemoglobin on electrodeposited cobalt-oxide nanoparticles: direct voltammetry and electrocatalytic activity. Biophys Chem 130:122–131.
  • Shan D, Wang SX, Xue HG, Cosnier S. 2007. Direct electrochemistry and electrocatalysis of hemoglobin entrapped in composite matrix based on chitosan and CaCO3 nanoparticles. Electroanal Chem 9:529–534.
  • Sheng QL, Zheng JB, Shang-Guan XD, Lin WH, Li YY, Liu RX. 2010. Direct electrochemistry and electrocatalysis of heme-proteins immobilized in porous carbon nanofiber/room- temperature ionic liquid composite film. Electrochim Acta 55:3185–3193.
  • Shu XH, Chen Y, Yuan HY, Gao SF, Xiao D. 2007. H2O2 sensor based on the room-temperature phosphorescence of nano TiO2/SiO2 composite. Anal Chem 79:3695–3702.
  • Sun W, Wang DD, Gao RF, Jiao K. 2007. Direct electrochemistry and electrocatalysis of hemoglobin in sodium alginate film on a BMIMPF6 modified carbon paste electrode. Electrochem Commun 9:1159–1164.
  • Sun AL, Zhao HY, Zheng JB. 2012. A novel hydrogen peroxide biosensor based on the Sn–ZnNPs/MWNTs nanocomposite film. Talanta 88:259–264.
  • Tan XC, Zhang JL, Tan SW, Zhao DD, Huang ZW, Mi Y, Huang ZY. 2009. Amperometric hydrogen peroxide biosensor based on immobilization of hemoglobin on a glassy carbon electrode modified with Fe3O4/chitosan core-shell microspheres. Sensors 9:6185–6199.
  • Xiong HY, Chen T, Zhang XH, Wang SF. 2007. High performance and stability of a hemoglobin-biosensor based on an ionic liquid as nonaqueous media for hydrogen peroxide monitoring. Electrochem Commun 9:2671–2675.
  • Xu J, Liu CH, Teng YL. 2010a. Direct electrochemistry and electrocatalysis of hydrogen peroxide using hemoglobin immobilized in hollow zirconium dioxide spheres and sodium alginate films. Microchim Acta 169:181–186.
  • Xu YX, Hu CG, Hu SH. 2010b. Electrochemical behavior of biocatalytical composite based on heme-proteins, didodecyldimethylammonium bromide and room-temperature ionic liquid. Anal Chim Acta 663:19–26.
  • Xuan J, Jia XD, Jiang LP, Abdel-Halim ES, Zhu JJ. 2012. Gold nanoparticle-assembled capsules and their application as hydrogen peroxide biosensor based on hemoglobin. Bioelectrochemistry 84:32–37.
  • Yan R, Zhao FQ, Li JW, Xiao F, Fan SS, Zeng BZ. 2007. Direct electrochemistry of horseradish peroxidase in gelatin-hydrophobic ionic liquid gel films. Electrochim Acta 52:7425–7431.
  • Zhao YD, Bi YH, Zhang WD, Luo QM. 2005. The interface behavior of hemoglobin at carbon nanotube and the detection for H2O2. Talanta 65:489–494.
  • Zhao G, Xu JJ, Chen HY. 2006. Fabrication, characterization of Fe3O4 multilayer film and its application in promoting direct electron transfer of hemoglobin. Electrochem Commun 8:148–154.
  • Zheng W, Zheng YF, Jin KW, Wang N. 2008. Direct electrochemistry and electrocatalysis of hemoglobin immobilized in TiO2 nanotube films. Talanta 74:1414–1419.
  • Zhou YZ, Wang H, Dong SY, Tian AX, He ZX, Chen B. 2011. Direct electrochemistry and electrocatalysis of myoglobin in dodecyltrimethylammonium bromide film modified carbon ceramic electrode. Chin J Chem 22:465–468.
  • Zhou YZ, Zhang HY, Chen B, Wang H. 2012. A novel hydrogen peroxide sensor based on immobilization of haemoglobin on nano-TiO2/DTAB composite film. Biocatal Biotransfor 30: 377–384.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.