References
- Aitchlson G. U. Use of a FaxitronX-ray cabinet for the rapid detection of the end point of decalcification. Med. Lab. Sci. 1979; 36: 195–196
- Anderson C. Manual for the Examination of Bone. CRC Press, Inc., Boca Raton, FL 1972; 20, 74.
- Butler J. N. Ionic Equilibrium. A Mathematical Approach. Addison-Wesley Publishing Co., Inc., Reading, MA 1964; 210–213.
- Ham A. W. Microscopy and biology of interphase nuclei of functioning specialized cells. Histology. Vol. 7. J. B. Lippincott Co., Philadelphia, PA 1969; 96.
- Hintze J. L. Number Cruncher Statistical System Version 5.03 9/91. NCSS, Kaysville, UT 1991; 1–442.
- Hornbeck C., Emmanual J., Bloebaum R. D. A comparative study of three paraffin media for preparing large decalcified bone sections. J. Histotechnol. 1986; 9: 227–229
- Kiviranta I., Tammi M., Lappalainen R., Kuusela T., Helminen H. J. The rate of calcium extraction during EDTA decalcification from thin bone slices as assessed with atomic absorption spectrophotometry. Histochemistry 1980; 68: 119–127
- Laitinen H. A. Chemical Analysis. An Advanced Text and Reference., W. C. Fernelius, L. P. Hammett, D. N. Hume, J. D. Roberts, H. H. Williams. McGraw-Hill Book Co., Inc., New York, NY 1960; 97–98, 228-235.
- Lillie R. D., Laskey A., Greco J., Jacquier Burtner H., Jones P. Decalcification of bone in relation to staining and phosphatase technics. Am. J. Clin. Pathol. 1951; 21: 711–722
- Luna L. G. Manual of Histologic Staining Methods of the Armed Forces Institute of Pathology. McGraw Hill Book Co., New York, NY 1968; 10, 36.
- Mawhinney W. H. B., Richardson E., Malcolm A. J. Technical methods. Control of rapid nitric acid decalcification. J. Clin. Pathol. 1984; 37: 1409–1415
- Milan L., Trachtenberg M. C. Ultrasonic decalcification of bone. Am. J. Surg. Pathol. 1981; 5: 573–579
- Page K. M. Bone and the preparation of bone sections. Theory and Practice of Histological Techniques., J. D. Bancroft, A. Stevens. Churchill Livingstone, Edinburgh 1982; 306, 309–310, 324-325.
- Poston F. Bone decalcification expedited by ultrasonic sound. J. Med. Technol. 1967; 33: 263–268
- Rosen A. D. End point determination in EDTA decalcification using ammonium oxalate. Stain Technol. 1981; 56: 48–49
- Skedros J. G., Bloebaum R. D., Bachus K. N., Boyce T. M. The meaning of gray levels in backscattered electron images of bone. J. Biomed. Mater. Res. 1993a; 27: 47–56
- Skedros J. G., Bloebaum R. D., Bachus K. N., Boyce T. M., Constantz B. Influence of mineral content and composition on gray levels in backscattered electron images of bone. J. Biomed. Mater. Res. 1993b; 27: 57–64
- Stevens A. The haematoxylins. Theory and Practice of Histological Techniques., J. D. Bancroft, A. Stevens. Churchill Livingstone, New York, NY 1982; 110.
- Thorpe E. J., Bellomy B. B., Sellers R. F. Ultrasonic decalcification of bone. An experimental and clinical study. J Bone Joint Surg. 1963; 45-A: 1257–1259
- Urban K. Routine decalcification of bone. Lab. Med. 1981; 12: 207–212
- Verdenius H. H. W., Alma L. A quantitative study of decalcification methods in histology. J. Clin. Pathol. 1958; 11: 229–236
- Villanueva A. R. Experimental studies in demineralization and its effects on cytology and staining of bone and marrow cells. J. Histotechnol. 1986; 9: 155–161