References
- Zeintl, H., Sack, F. U., Intaglietta, M., Messmer, K. (1989). Computer assisted leukocyte adhesion measurement in intravital microscopy. Int. J. Microcirc. Clin. Exp. 8: 293–302.
- Klyscz, T., Jünger, M., Jung, F., Zeintl, H. (1997). Cap Image - a new kind of computer-assisted video image analysis system for dynamic capillary microscopy. Biomed. Tech. Berl. 42(6):168–175.
- Slaaf, D. W., Jeurens, T. J., Tangelder, G. J., Reneman, R. S., Arts, T. (1986). Methods to measure blood flow velocity of red blood cells in vivo at the microscopic level. Ann. Biomed. Eng. 14 (2): 175–186.
- Bloch, E. H. (1962). A quantitative study of the hemodynamics in the living microvascular system. Am. J. Anat. 110 (3): 125–153.
- Tyml, K., Ellis, C. G. (1982). Evaluation of the flying spot technique as a television method for measuring red cell velocity in microvessels. Int. J. Microcirc. Clin. Exp. 1 (2): 145–155.
- Munro, P. A. G. (1966). Advances in Optical and Electron Microscopy, Academic Press New York, 1–40.
- Kiesewetter, H., Radtke, H., Korber, N., Schmid-Schonbein, H. (1982). Experimental calibration of a two-stage prism-grating system for measuring cell velocity. Microvasc. Res. 23 (1): 56–66.
- Wayland, H., Johnson, P. C. (1967). Erythrocyte velocity measurement in microvessels by a two-slit photometric method. J. Appl. Physiol. 22 (2): 333–337.
- Silva, J., Intaglietta, M. (1974). The correlation of photometric signals derived from in vivo red blood cell flow in microvessels. Microvasc. Res. 7 (2): 156–169.
- Arfors, K. E., Bergqvist, D., Intaglietta, M., Westergren, B. (1975). Measurements of blood flow velocity in the microcirculation. Ups. J. Med. Sci. 80 (1): 27–33.
- Slaaf, D. W., Rood, J. P., Tangelder, G. J., Jeurens, T. J., Alewijnse, R., Reneman, R. S., Arts, T. (1981). A bidirectional optical (BDO) three-stage prism grating system for on-line measurement of red blood cells velocity in microvessels. Microvasc. Res. 22 (1): 110–122.
- Fleming, B. P., Klitzman, B., Johnson, W. O. (1985). Measurement of erythrocyte velocity by use of a periodic differential detector. Am. J. Physiol. 249 (4 Pt 2): H899–905.
- Ishikawa, M., Sekizuka, E., Shimizu, K., Yamaguchi, N., Kawase, T. (1998). Measurement of RBC velocities in the rat pial arteries with an image-intensified high-speed video camera system. Microvasc. Res. 56 (3): 166–172.
- Petrak, D., Przybilla, E., Astalosch, F., Kämpfe, L., Hädrich, T. (1989). Fiberoptical spatial filter anemometry, a local measuring technique for multiphase flows. Techn. Messen. tm. 56: 72–83.
- Endrich, B., Asaishi, K., Götz, A., Messmer, K. (1980). Technical report - a new chamber technique for microvascular studies in unanesthetized hamsters. Res. Exp. Med. Berl. 177: 125–134.
- Nolte, D., Menger, M. D., Messmer, K. (1995). Microcirculatory models of ischemia-reperfusion injury in skin and striated muscle. Int. J. Microcirc. Clin. Exp. 15 (Suppl. 1): 9–16.
- NIH. (1985). Guide for the Care and Use of Laboratory Animals.
- Ator, J. T. (1963). Image-velocity sensing with parallel-slit reticles. J. Optical. Soc. 1-12-53 (12): 1416–1422.
- Fiedler, O., Labahn, N., Müller, I., Christofori, K. (1994). Halbleiterbildsensor als Ortsfiltersonde - ein Verfahren zur Messung lokaler Partikelgeschwindigkeiten in zirkulierenden Wirbelschichten. Chem. Ing. Tech. 66 (1): 79–82.
- Dietmayer, K. (1994). On the precision of the remote 2D velocity measurement using CCD sensors. OPTO94 Kongressband, 304–310.
- Borders, J. L., Granger, H. J. (1984). An optical doppler intravital velocimeter. Microvasc. Res. 27 (1): 117–127.
- Fiedler, O., Schulz, K. P., Christofori, K. (1988). Spatial filter anemometry for velocity measurement with a CCD-camera. MSR (Messen,Steuern, Regeln) Berlin 31: 205–209.
- Colantuoni, A., Bertuglia, S. (1997). Correlation between laser Doppler perfusion monitoring and hematocrit in hamster cheek pouch microcirculation. Int. J. Microcirc. Clin. Exp. 17 (1): 33–40.
- Tsai, A. G., Intaglietta, M. (1993). Evidence of flowmotion induced changes in local tissue oxygenation. Int. J. Microcirc. Clin. Exp. 12: 75–88.
- Steinbauer, M., Harris, A. G., Abels, C., Messmer, K. (2000). Characterization and prevention of phototoxic effects in intravital fluorescence microscopy in the hamster dorsal skinfold model. Langenbecks. Arch. Chir. 385: 290–298.
- Sarelius, I. H. (1989). Microcirculation in striated muscle after acute reduction in systemic hematocrit. Respir. Physiol. 78: 7–17.
- Cabrales, P., Tsai, A. G., Intaglietta, M. (2008). Isovolemic exchange transfusion with increasing concentrations of low oxygen affinity hemoglobin solution limits oxygen delivery due to vasoconstriction. Am. J. Physiol Heart Circ. Physiol 295 (5): H2212–H2218.
- Nolte, D., Zeintl, H., Steinbauer, M., Pickelmann, S., Messmer, K. (1995). Functional capillary density: an indicator of tissue perfusion? Int. J. Microcirc. Clin. Exp. 15 (5): 244–249.
- Chang, T. M. (2006). Evolution of artificial cells using nanobiotechnology of hemoglobin based RBC blood substitute as an example. Artif. Cells Blood Substit. Immobil. Biotechnol. 34 (6): 551–566.
- Brauer, K., Hahn, M. (1999). Nonlinear analysis of blood flux in human vessels. Phys. Med. Biol. 44 (7): 1719–1733.
- Fagrell, B. (1986). Microcirculatory methods for the clinical assessment of hypertension, hypotension, and ischemia. Ann. Biomed. Eng. 14 (2): 163–173.
- Einav, S., Berman, H. J., Fuhro, R. L., DiGiovanni, P. R., Fine, S., Fridman, J. D. (1975). Measurement of velocity profiles of red blood cells in the microcirculation by laser doppler anemometry (LDA). Biorheology. 12 (3-4): 207–210.
- Messmer, K. (2000). Orthogonal Polarization Spectral Imaging - A new tool for the observation and measurment of the human microcirculation. Progress in Applied Microcirculation (24): 1–122.