398
Views
19
CrossRef citations to date
0
Altmetric
Original Article

Image-Based Planning and Validation of C1-C2 Transarticular Screw Fixation Using Personalized Drill Guides

, , , &
Pages 41-48 | Received 15 Oct 1999, Accepted 16 Dec 2001, Published online: 06 Jan 2010

References

  • Magerl F, Seeman P S. Stable posterior fusion of the atlas and axis by transarticular screw fixation. Cervical Spine, P Kehr, A Weidner. Springer Verlag, Vienna 1987; 322–317
  • Grob D, Jeanneret B, Aebi M, et al. Atlanto-axial fusion with transarticular screw fixation. J Bone Joint Surg [Br] 1991; 73: 972–976
  • Smith M D., Phillips W A., Hensinger R N. Complications of fusion to the upper cervical spine. Spine 1991; 16: 702–705
  • Panjabi C G., Dvorak J, Duranceau J, et al. Three-dimensional movements of the upper spine. Spine 1988; 13: 726–730
  • Grob D, Crisco J J., III, Panjabi M. Biomechanical evaluation of four different posterior atlanto-axial fixation techniques. Spine 1992; 17: 480–490
  • Hanson P, Montesano P, Sharkey N, Rauschning W. Anatomic and biomechanical assessment of transarticular screw fixation for atlantoaxial instability. Spine 1991; 16: 1141–1150
  • Montesano P X., Anderson P A., et al. Biomechanics of cervical spine internal fixation. Spine 1991; 16(Suppl)S10–S16
  • Wilke H J., Fischer K, Kuger A, Magerl F, Claes L. Wörsdörfer In vitro investigations of internal fixation systems of the upper cervical spine. II: Stability of posterior atlanto-axial fixation techniques. Eur Spine J 1992; 1: 191–199
  • Brooks A L., Jenkins E W. Atlanto-axial arthrodesis by the wedge compression method. J Bone Joint Surg [Am] 1978; 60: 279–284
  • Gallie W E. Fractures and dislocations of the upper cervical spine. Am J Surg 1939; 46: 495–499
  • Hajek P, Lipka J, Hartline P, Sana S, Albright J. Biomechanical study of C1-C2 posterior arthrodesis techniques. Spine 1993; 18: 173–177
  • Jeanneret B, Magerl F. Primary posterior fusion C1–2 in odontoid fractures: indications, technique and results of transarticular screw fixation. J Spinal Disord 1992; 5: 464–475
  • Madawi A A., Casey A TH, Solanki G A., Tuite G, Veres R, Crockard H A. Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique. J Neurosurg 1997; 86: 961–968
  • Marcotte P, Dickman C A., Sonntag V KH. Posterior atlantoaxial facet screw fixation. J Neurosurg 1993; 79: 234–237
  • McGuire R A., Jr, Harkey H L. Focus on the spine: modification of technique and results of atlantoaxial transfacet stabilization. Orthopedics 1995; 18: 1029–1032
  • Sasso R C., Jeanneret B, Fischer K. Occipitocervical fusion with posterior plate and screw instrumentation. A long-term follow-up study. Spine 1994; 19: 2364–2368
  • Stillerman C B., Wilson J A. Atlanto-axial stabilization with posterior transarticular screw fixation: technical description and report of 22 cases. Neurosurgery 1993; 32: 948–955
  • Radermacher K, Portheine F, Anton M, Zimolong A, Kaspers G, Rau G, Staudte H W. Computer assisted orthopaedic surgery with image based individual templates. Clinical Orthop Rel Res 1998; 354: 28–38
  • Radermacher K, Rau G, Staudte H W. Computer-integrated orthopaedic surgery: connection of planning and execution in surgical intervention. Computer-Integrated Surgery: Technology and Clinical Applications, R H. Taylor, S Lavallée, G C. Burdea, R Mösges. MIT Press, Cambridge MA 1996; 451–463
  • Goffin J, Van Brussel K, Vander Sloten J, Van Audekercke R, Smet M H., Marchal G, Van Craen W, Swaelens B, Verstreken K. 3D-CT based, personalized drill guide for posterior transarticular screw fixation at C1-C2: technical note. Neuro-Orthopedics 1999; 25: 47–56
  • Verstreken K, Van Cleynenbreugel J, Martens K, Marchal G, van Steenberghe D, Suetens P. An image-guided planning system for endosseous oral implants. IEEE Trans Med Imaging 1998; 17: 842–852
  • Maes F, Collignon A, Vandermeulen D, Marchal G, Suetens P. Multimodality image registration by maximization of mutual information. IEEE Trans Med Imaging 1997; 16: 187–198
  • Van Cleynenbreugel J, Schutyser F, Malevez C, Dhoore E, BouSerhal C, Jacobs R, Suetens P, van Steenberghe D. Intra-operative transfer of planned zygomatic fixtures by personalized templates: a cadaver validation study. October, 2001, Presentation at MICCAI 2001, Utrecht, The Netherlands
  • Berlemann U, Monin D, Arm E, Nolte L P., Ozdoba C. Planning and insertion of pedicle screws with computer assistance. J Spinal Disord 1997; 10: 117–124
  • Merloz P, Tonetti J, et al. Computer assisted spine surgery. Clin Orthop Rel Res 1997; 337: 86–96
  • Schwarzenbach O, Berlemann U, et al. Accuracy of computer-assisted pedicle screw placement. An in vivo computed tomography analysis. Spine 1997; 22: 452–458
  • Goffin J, Van Brussel K, Martens K, Vander Sloten J, Van Audekercke R, Smet M H. Three-dimensional computed tomography-based, personalized drill guide for posterior cervical stabilization at C1-C2. Spine 2001; 26: 1343–1347

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.