221
Views
7
CrossRef citations to date
0
Altmetric
Original Article

Remotely-Controlled Approach for Stereotactic Neurobiopsy

, &
Pages 237-247 | Received 27 Sep 2001, Accepted 16 Aug 2002, Published online: 06 Jan 2010

References

  • Leksell L A. Stereotaxic apparatus for intracerebral surgery. Acta Chir Scand 1949; 99: 229–233
  • Spiegel E A. Development of stereoencephalotomy for extrapyramidal diseases. J Neurosurg 1966; 24: 433–481
  • Spiegel E A., Wycis H T., Marks M, Lee A J. Stereotaxic apparatus for operations on the human brain. Science 1947; 106: 349–350
  • Spiegel E A., Wycis H T., Kletzkin M, Thur C. A new procedure for exploration and elimination of subcortical structures. Electroencephalogr Clin Neurophysiol 1953; 5: 309–311
  • Spiegel E A., Wycis H T., Kletzkin M, Thur C. A universal stereoencephalotome (model V) for use in man and experimental animals. J Neurosurg 1956; 13: 305–309
  • Austin G, Lee A. A plastic ball-and-socket type of stereotaxic director. J Neurosurg 1958; 15: 264–268
  • Rand R W. A stereotaxic instrument for pallidothalamectomy. J Neurosurg 1961; 18: 258–260
  • Guiot P G. Le traitement des syndromes parkinsoniens par la destruction du pallidum interne. Neurochirurgia 1958; 1: 94–98
  • Bleasel K, Harrison J, Miller D. A new approach to stereotaxic localization. Med J Aust 1964; 19: 717–722
  • Markham C H., Rand R W. Stereotaxic surgery in Parkinson's disease. Arch Neurol 1963; 8: 51–61
  • Kelly P J., Kaü B A., Goerss S, Earnest F IV. Computer-assisted stereotaxic laser resection of intra-axial brain neoplasms. J Neurosurg 1986; 64: 427–439
  • Maciunas R J., Galloway R L., Fitzpatrick J M., et al. A universal system for interactive image-directed neurosurgery. Stereotact Funct Neurosurg 1992; 58: 108–113
  • Koivukangas J, Louhisalmi Y, Alakuijala J, Oikarinen J. Ultrasound controlled neuronavigator guided brain surgery. J Neurosurg 1993; 79: 36–42
  • Barnett G H., Kormos D W., Steiner C P., et al. Use of a frameless, armless stereotactic wand for brain tumor localization with 2D and 3D neuroimaging. Neurosurgery 1993; 33: 674–678
  • Golfinos J G., Fitzpatrick B C., Smith L R., Spetzler R F. Clinical use of a frameless stereotactic arm: results of 325 cases. J Neurosurg 1995; 83: 197–205
  • Spetzger U, Laborde G, Gilsbach J M. Frameless neuronavigation in modern neurosurgery. Minim Invasive Neurosurg 1995; 38: 163–166
  • Laborde G, Gilsbach J, Harders A, Klimek L, Mösges R, Krybus W. Computer assisted localizer for planning of surgery and intra-operative orientation. Acta Neurochir (Wien) 1992; 119: 166–170
  • Hata N, Dohi T, Iseki H, Takakura K. Development of a frameless and armless stereotactic neuronavigation system with ultrasonographic registration. Neurosurgery 1997; 41: 608–614
  • Olson J J., Shepherd S, Bakay R AE. The EasyGuide Neuro image-guided surgery system. Neurosurgery 1997; 40: 1092–1096
  • Reinges M HT, Spetzger U, Rohde V, Adams L, Gilsbach J M. Experience with a new multifunctional articulated instrument holder in minimally invasive navigated neurosurgery. Minim Invasive Neurosurg 1998; 41: 149–151
  • Mueller P R., Stark D D., Simeone J F., Saini S. Butch RJ, Edelman RR, Wittenberg J, Ferrucci JT. MR-guided aspiration biopsy: needle design and clinical trials. Radiology 1986; 161: 605–609
  • Lfkin R B., Teresi L, Hanafee W N. A new needle for MR-guided aspiration cytology of the head and neck. AJR 1987; 149: 380–382
  • van Sonnenberg E, Hajek P, Gylys-Morin V, Vamey R A., Baker L, Casola G. Christensen R, Mattrey RF. A wire-sheath system for MR-guided biopsy and drainage: laboratory studies and experience in 10 patients. AJR 1988; 161: 815–817
  • Lufkin R B. Interventional MR imaging. Radiology 1995; 197: 16–18
  • Silverman S G., Collick B D., Figueira M R., Khorasani R, Adams RW Newman R W., Topulos G P., Jolesz F A. Interventional MR-guided biopsy in an open-configuration MR imaging system. Radiology 1995; 197: 175–181
  • Schenck J F., Jolesz F A., Roemer P B., Cline H E., Lorensen W E., Kikinis R, Silverman S G., Hardy C J., Barber W D., Laskaris E T., Dorri B, Newman R W., Holley C E., Collick B D., Dietz D P., Mack D C., Ainslie M D., Jaskolski P L., Figueira M R., vom Lehn J C., Souza S P., Dumoulin C L., Darrow R D., St Peters R L., Rohling K W., Watkins R D., Eisner D R., Blumenfeld S M., Vosburgh K G. Superconducting open configuration MRI system for image-guided therapy. Radiology 1995; 195: 805–814
  • Minimally Invasive Therapy of the Brain, A A. De Salles, R B. Lufkin. Thieme, New York 1997
  • Liu H, Martin A J., Truwit C L. Interventional MRI at high-field (1.5T): needle artifacts. J Magn Reson Imaging 1998; 8: 214–219
  • van Vaals J J., van Yperen G H., Hoogenboom T LM, et al. Local Look (LoLo): zoom-fluoroscopy of a moving target. In: Proceedings of the First Meeting of the Society of Magnetic Resonance, Dallas, 1994. J Magn Reson Imaging 1994; 4(P)38
  • Dumoulin C L., Souza S P., Darrow R D. Real-time position monitoring of invasive device using magnetic resonance. Magn Reson Med 1993; 29: 411–415
  • Black P M., Moriarty T, Alexander E, et al. Development and implementation of intraoperative magnetic resonance imaging and its neurosurgical applications. Neurosurgery 1997; 41: 831–842
  • Jolesz F A. Image-guided procedures and the operating room of the future. Radiology 1997; 204: 601–612
  • Hall W A., Liu H, Martin A J., Casey S O., Michel E, Pozza C H., Kucharczyk J, McCue M, Nussbaum E S., Maxwell R E., Truwit C L. The safety, efficacy, and functionality of high field strength interventional magnetic resonance imaging for neurosurgery. Neurosurgery 2000; 46: 632–642
  • Sutherland G R., Kaibara T, Louw D, Saunders J. A mobile high field strength magnetic resonance imaging system for neurosurgery. Neurosurg Focus 1999; 6(3), article 6
  • Lewin J S., Metzger A, Selmen W R. Intraoperative magnetic resonance image guidance in neurosurgery. J Magn Imaging 2000; 12: 512–524
  • Hall W A., Martin A J., Liu H, Pozza C H., Casey S O., Michel E, Nussbaum E S., Maxwell R E., Truwit C L. Brain biopsy using high field strength interventional magnetic resonance imaging. Neurosurgery 1999; 44: 807–814
  • Liu H, Hall W A., Martin A J., Maxwell R E., Truwit C L. MR-guided and monitored neurosurgical procedures at 1.5 Tesla. J Comp Assist Tomogr 2000; 24: 909–918
  • Maurer C R., Hill D LG, Martin A J., Liu H, McCue M, Rueckert D, Lloret D, Hall W A., Maxwell R E., Hawkes D J., Truwit C L. Investigation of intraoperative brain deformation using 1.5 Tesla interventional MR system: preliminary results. IEEE Trans Med Imaging 1998; 17: 817–825
  • Hall W A., Martin A J., Liu H, Pozza C H., Casey S O., Michel E, Nussbaum E S., Maxwell R E., Truwit C L. High field strength interventional magnetic resonance imaging for neurosurgery. Pediatr Neurosurg 1998; 29: 253–259

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.