852
Views
20
CrossRef citations to date
0
Altmetric
Biomedical Paper

Respiratory motion compensation for CT-guided interventions in the liver

, , , , , , , , & show all
Pages 125-138 | Received 06 Jun 2007, Accepted 11 Feb 2008, Published online: 06 Jan 2010

References

  • McGahan JP, Dodd GD. Radiofrequency ablation of the liver: Current status. Am J Roentgenol 2001; 176: 3–16
  • Ahmed M, Goldberg SN. Thermal ablation therapy for hepatocellular carcinoma. J Vasc Interv Radiol 2002; 13(9)231–243
  • Rohlfing T, Maurer CR, O’Dell WG, Zhong J. Modeling liver motion and deformation during the respiratory cycle using intensity-based nonrigid registration of gated MR images. Med Phys 2004; 31(3)427–432
  • Clifford MA, Banovac F, Levy E, Cleary K. Assessment of hepatic motion secondary to respiration for computer assisted interventions. Comput Aided Surg 2002; 7(5)291–299
  • Banovac F, Tang J, Xu S, Lindisch D, Chung HY, Levy E, Chang T, McCullough MF, Yaniv Z, Wood BJ, Cleary K. Precision targeting of liver lesions using a novel electromagnetic navigation device in physiologic phantom and swine. Med Phys 2005; 32(8)2698–2705
  • Nicolau S, Garcia A, Pennec X, Soler L, Ayache N. An augmented reality system to guide radiofrequency tumour ablation. Comput Animat Virt W 2005; 16(1)1–10
  • Nagel M, Schmidt G, Petzold R, Kalender WA (2005) A navigation system for minimally invasive CT-guided interventions. Proceedings of the 8th International Conference on Medical Image Computing and Computer-Assisted Intervention (MICCAI 2005), Palm Springs, CA, October, 2005, JS Duncan, G Gerig. Springer, Berlin, 33–40, Part II. Lecture Notes in Computer Science 3750
  • Fichtinger G, Deguet A, Fischer G, Iordachita I, Balogh E, Masamune K, Taylor RH, Fayad LM, de Oliveira M, Zinreich SJ. Image overlay for CT-guided needle insertions. Comput Aided Surg 2005; 10(4)241–255
  • Khan MF, Dogan S, Maataoui A, Wesarg S, Gurung J, Ackermann H, Schiemann M, Wimmer-Greinecker G, Vogl TJ. Navigation-based needle puncture of a cadaver using a hybrid tracking navigational system. Invest Radiol 2006; 41(10)713–720
  • Schweikard A, Glosser G, Bodduluri M, Murphy MJ, Adler JR. Robotic motion compensation for respiratory movement during radiosurgery. Comput Aided Surg 2000; 5(4)263–277
  • Khamene A, Warzelhan JK, Vogt S, Elgort D, Chefd’Hotel C, Duerk JL, Lewin JS, Wacker FK, Sauer F (2004) Proceedings of the 7th International Conference on Medical Image Computing and Computer-Assisted Intervention (MICCAI 2004), Saint-MaloFrance, September, 2004, C Barillot, DR Haynor, P Hellier. Springer, Berlin, 526–533, Part II. Lecture Notes in Computer Science 3217
  • Zhang H, Banovac F, Lin R, Glossop N, Wood BJ, Lindisch D, Levy E, Cleary K. Electromagnetic tracking for abdominal interventions in computer aided surgery. Comp Aid Surg 2006; 11(3)127–136
  • Maier-Hein L, Müller SA, Pianka F, Müller-Stich BP, Gutt CN, Seitel A, Rietdorf U, Meinzer HP, Richter G, Schmied BM, Wolf I. In-vitro evaluation of a novel needle-based soft tissue navigation system with a respiratory liver motion simulator. Proceedings of SPIE Medical Imaging 2007: Visualization, Image-Guided Procedures, and Display, San Diego, CA, February, 2007, KR Cleary, MI Miga, 650916: 6509, SPIE Proceedings 2007
  • Nagel M, Hoheisel M, Petzold R, Kalender WA, Krause UHW. Needle and catheter navigation using electromagnetic tracking for computer-assisted C-arm CT interventions. Proceedings of SPIE Medical Imaging 2007: Visualization, Image-Guided Procedures, and Display, San Diego, CA, February, 2007, KR Cleary, MI Miga, 65090J: 6509, SPIE Proceedings 2007
  • Maier-Hein L, Maleike D, Neuhaus J, Franz A, Wolf I, Meinzer HP. Soft tissue navigation using needle-shaped markers: Evaluation of navigation aid tracking accuracy and CT registration. Proceedings of SPIE Medical Imaging 2007: Visualization, Image-Guided Procedures, and Display, San Diego, CA, February, 2007, KR Cleary, MI Miga, 650926: 6509, SPIE Proceedings 2007
  • Davis MH, Khotanzad A, Flamig DP, Harms SE. A physics-based coordinate transformation for 3-d image matching. IEEE Trans Med Imaging 1997; 16(3)317–328
  • Harder RL, Desmarais RN. Interpolation using surface splines. J Aircraft 1972; 9(2)189–191
  • Bookstein FL. Principal warps: Thin-plate splines and the decomposition of deformations. IEEE T Pattern Anal 1989; 11(6)567–585
  • Nielson GM. Scattered data modeling. IEEE Comput Graph 1993; 13(1)60–70
  • Rohr K. Landmark-Based Image Analysis: Using Geometric and Intensity Models. Kluwer Academic Publishers, DordrechtThe Netherlands 2001
  • Rohr K, Stiehl HS, Sprengel R, Buzug TM, Weese J, Kuhn MH. Landmark-based elastic registration using approximating thin-plate splines. IEEE T Med Imaging 2001; 20(6)526–34
  • Ibañez L, Schroeder W, Ng L, Cates J. The Insight Software Consortium. The ITK Software Guide. Second Edition. 2005, http://www.itk.org
  • Wolf I, Vetter M, Wegner I, Böttger T, Nolden M, Schöbinger M, Hastenteufel M, Kunert T, Meinzer HP. The Medical Imaging Interaction Toolkit. Med Image Anal 2005; 9(6)594–604
  • Horn B. Closed-form solution of absolute orientation using unit quaternions. J Opt Soc Am A 1987; 4(4)629–642
  • Maier-Hein L, Pianka F, Müller SA, Rietdorf U, Wolf I, Schmied BM, Meinzer HP. Atembewegungssimulator für die in-vitro Evaluation von Weichgewebe-Navigations systemen in der Leber. Bildverarbeitung für die Medizin, A Horsch, TM Deserno, H Handels, HP Meinzer, T Tolxdorf. Springer, Berlin 2007; 379–383
  • Zhang H, Banovac F, Glossop ND, Cleary K (2005) Two-stage registration for real-time deformable compensation using an electromagnetic tracking device. Proceedings of the 8th International Conference on Medical Image Computing and Computer-Assisted Intervention (MICCAI 2005), Palm Springs, CA, October, 2005, JS Duncan, G Gerig. Springer, Berlin, 992–999, Part II. Lecture Notes in Computer Science 3750

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.