References
- Wich M, Spranger N, Ekkernkamp A. [Intraoperative imaging with the ISO C(3D)]. Chirurg 2004; 75(10)982–987
- Euler E, Heining S, Riquarts C, Mutschler W. C-arm-based three-dimensional navigation: a preliminary feasibility study. Comput Aided Surg 2003; 8(1)35–41
- Grützner PA, Beutler T, Wendl K, von Recum J, Wentzensen A, Nolte LP. [Intraoperative three-dimensional navigation for pedicle screw placement]. Chirurg 2004; 75(10)967–975
- Kendoff D, Geerling J, Mahlke L, Citak M, Kfuri M Jr, Hufner T, Krettek C. [Navigated Iso-C(3D)-based drilling of a osteochondral lesion of the talus]. Unfallchirurg 2003; 106(11)963–967
- Wendl K, von Recum J, Wentzensen A, Grützner PA. [Iso-C(3D0-assisted) navigated implantation of pedicle screws in thoracic lumbar vertebrae]. Unfallchirurg 2003; 106(11)907–913
- Briem D, Linhart W, Lehmann W, Begemann PG, Adam G, Schumacher U, Cullinane DM, Rueger JM, Windolf J. Computer-assisted screw insertion into the first sacral vertebra using a three-dimensional image intensifier: results of a controlled experimental investigation. Eur Spine J 2005; 15(6)757–763
- Kendoff D, Hufner T, Citak M, Geerling J, Mossinger E, Bastian L, Krettek C. Navigated Iso-C(3D)-based percutaneous osteoid osteoma resection: A preliminary clinical report. Comput Aided Surg 2005; 10(3)157–163
- Citak M, Kendoff D, Wanich T, Pearle A, Singhai R, Krettek C, Hufner T. The influence of distance on registration in ISO-C-3D navigation: a source of error in ISO-C-3D navigation. Technol Health Care 2006; 14(6)473–478
- Kotsianos D, Wirth S, Fischer T, Euler E, Rock C, Linsenmaier U, Pfeifer KJ, Reiser M. 3D imaging with an isocentric mobile C-arm: comparison of image quality with spiral CT. Eur Radiol 2004; 14(9)1590–1595
- Hufner T, Geerling J, Kfuri M Jr, Gansslen A, Citak M, Kirchhoff T, Sott AH, Krettek C. Computer assisted pelvic surgery: registration based on a modified external fixator. Comput Aided Surg 2003; 8(4)192–197
- Gebhard F, Kinzl L, Arand M. [Limits of CT-based computer navigation in spinal surgery]. Unfallchirurg 2000; 103(8)696–701
- Nolte LP, Beutler T. Basic principles of CAOS. Injury 2004; 35(Suppl 1)S-A6–S-A16
- Hufner T, Geerling J, Oldag G, Richter M, Kfuri M Jr, Pohlemann T, Krettek C. Accuracy study of computer-assisted drilling: the effect of bone density, drill bit characteristics, and use of a mechanical guide. J Orthop Trauma 2005; 19(5)317–322
- Acosta FL, Jr, Thompson TL, Campbell S, Weinstein PR, Ames CP. Use of intraoperative isocentric C-arm 3D fluoroscopy for sextant percutaneous pedicle screw placement: case report and review of the literature. Spine J 2005; 5(3)339–343
- Arand M, Kinzl L, Gebhard F. [Sources of error and risks in CT based navigation]. Orthopade 2002; 31(4)378–384
- Eschbach L. Nonresorbable polymers in bone surgery. Injury 2000; 31(Suppl 4)22–27
- Ferguson SJ, Visser JM, Polikeit A. The long-term mechanical integrity of non-reinforced PEEK-OPTIMA polymer for demanding spinal applications: experimental and finite-element analysis. Eur Spine J 2006; 15(2)149–156
- Toth JM, Wang M, Estes BT, Scifert JL, Seim HB, 3rd, Turner AS. Polyetheretherketone as a biomaterial for spinal applications. Biomaterials 2006; 27(3)324–334