References
- Pierchon F, Pasquier G, Cotten A, Fontaine C, Clarisse J, Duquennoy A. Causes of dislocation of total hip arthroplasty. CT study of component alignment. J Bone Joint Surg Br 1994; 76: 45–48
- Wines AP, McNicol D. Computed tomography measurement of the accuracy of component version in total hip arthroplasty. J Arthroplasty 2006; 21: 696–701
- Dandachli W, Nakhla A, Iranpour F, Kannan V, Cobb JP. Can the acetabular position be derived from a pelvic frame of reference?. Clin Orthop Relat Res 2009; 467(4)886–893
- Bargar WL, Jamali AA, Nejad AH. Femoral anteversion in THA and its lack of correlation with native acetabular anteversion. Clin Orthop Relat Res 2010; 468(2)527–532
- Maruyama M, Feinberg JR, Capello WN, D’Antonio JA. The Frank Stinchfield Award: Morphologic features of the acetabulum and femur: anteversion angle and implant positioning. Clin Orthop Relat Res 2001; 393: 52–65
- Murtha PE, Hafez MA, Jaramaz B, DiGioia AM. Variations in acetabular anatomy with reference to total hip replacement. J Bone Joint Surg Br 2008; 90(3)308–313
- Tohtz SW, Sassy D, Matziolis G, Preininger B, Perka C, Hasart O. CT evaluation of native acetabular orientation and localization: Sex-specific data comparison on 336 hip joints. Technol Health Care 2010; 18(2)129–136
- Babisch JW, Layher F, Amiot LP. The rationale for tilt-adjusted acetabular cup navigation. J Bone Joint Surg Am 2008; 90(2)357–365
- Parratte S, Pagnano MW, Coleman-Wood K, Kaufman KR, Berry DJ. The 2008 Frank Stinchfield Award: Variation in postoperative pelvic tilt may confound the accuracy of hip navigation systems. Clin Orthop Relat Res 2009; 467(1)43–49
- Zhu J, Wan Z, Dorr LD. Quantification of pelvic tilt in total hip arthroplasty. Clin Orthop Relat Res 2010; 468(2)571–575
- LaVelle M. Natural selection and developmental sexual variation in the human pelvis. Am J Phys Anthropol 1995; 98(1)59–72
- Hakki S. Acetabular center axis: A novel alternative registration point to anterior pelvic plane in navigated THA [abstract]. Proceedings of the 10th Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery (CAOS-International), Paris, France, June 2010. pp 255–256.
- Thornberry RL, Martin JD, Toole GC, Barbu A. Statistical variability of the anterior pelvic plane to the hip center ASIS pelvic plane [abstract]. Proceedings of the 10th Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery (CAOS-International), Paris, France, June 2010. pp 328–330.
- Murphy SB, Ecker TM. Evaluation of a new leg length measurement algorithm in hip arthroplasty. Clin Orthop Relat Res 2007; 463: 85–89
- Woolson ST, Hartfort JM, Sawyer A. Results of a method of leg-length equalization for patients undergoing primary total hip replacement. J Arthroplasty 1999; 14(2)159–164
- Massin P, Schmidt L, Engh CA. Evaluation of cementless acetabular component migration. An experimental study. J Arthroplasty 1989; 4(3)245–251
- Nunn D, Freeman MA, Hill PF, Evans SJ. The measurement of migration of the acetabular component of hip prostheses. J Bone Joint Surg Br 1989; 71-B(4)629–631
- Bowerman JW, Sena JM, Chang R. The teardrop shadow of the pelvis; anatomy and clinical significance. Radiology 1982; 143(3)659–662
- Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am A 1978; 60(2)217–220
- Murray DW. The definition and measurement of acetabular orientation. J Bone Joint Surg Br 1993; 75(2)228–232
- Motzny S. Bestimmung des Rotationszentrums über die Landmarken des Beckens. PhD thesis. Tübingen, 2011.
- Tague RG. Variation in pelvic size between males and females in nonhuman anthropoids. Am J Phys Anthropol 1995; 97(3)213–233