References
- ANSI S3.21-2004 (R2009). 2009. Methods for manual pure-tone audiometry. American National Standards Institute, New York.
- ANSI S3.1-1999. 1999. Maximum permissible ambient noise levels for audiometric test rooms. American National Standards Institute, New York.
- ANSI S3.6-2010. 2010. Specification for audiometers. American National Standards Institute, New York.
- Brännström K.J., Lantz J. 2010. Interaural attenuation for the Sennheiser HDA 200 circumaural earphones. Int J Audiol, 49, 467–471.
- Dean M.S., Martin F.N. 2000. Insert earphone depth and the occlusion effect. Am J Audiol, 9, 131–134.
- Dirks D.D., Lybarger S.F., Olsen W.O., Billings B.L. 1979. Bone conduction calibration: Current status. J Speech Hearing Dis, 44, 143–155.
- Elpern B., Naunton R. 1963. The stability of the occlusion effect. Arch Otolaryng, 77, 376–384.
- Frank T., Holmes A. 1981. Acoustic radiation from bone vibrators. Ear Hear, 2, 59–63.
- Ho A.T.P., Hildreth A.J., Lindsey L. 2009. Computer-assisted versus manual audiometry. Otol Neurotol, 30, 876–883.
- IEC 60318-1. 1998. Electroacoustics – Simulators of human head and ear – Part 1: Ear simulator for the calibration of supra-aural earphones. Geneva: International Electrotechnical Commission.
- IEC 60318-3. 1998. Electroacoustics – Simulators of human head and ear – Part 3: Acoustic coupler for the calibration of supra-aural earphones used in audiometry. Geneva: International Electrotechnical Commission.
- ISO 389.1. 1998. Acoustics – Reference zero for the calibration of audiometric equipment – Part 1: Reference equivalent threshold sound pressure levels for pure tones and supra-aural earphones. Geneva: International Organization for Standardization.
- ISO 389.3. 1994. Acoustics – Reference zero for the calibration of audiometric equipment – Part 3: Reference equivalent threshold force levels for pure tones and bone vibrators. Geneva: International Organization for Standardization.
- ISO 389-8. 2004. Acoustics – Reference zero for the calibration of audiometric equipment – Part 8: Reference equivalent threshold sound pressure levels for pure tones and circumaural earphones. Geneva: International Organization for Standardization.
- ISO 389-9. 2009. Acoustics – Reference zero for the calibration of audiometric equipment – Part 9: Preferred test conditions for the determination of reference hearing threshold levels. Geneva: International Organization for Standardization.
- Lightfoot G.R., Hughes J.B. 1993. Bone conduction errors at high frequencies: Implications for clinical and medico-legal practice. J Laryngol Otol, 107, 305–308.
- Margolis R.H. 2008. The vanishing air-bone gap: Audiology's dirty little secret. Audiology Online (www.audiologyonline.com/articles), October 20, 2008.
- Margolis R.H., Glasberg B.R., Creeke S., Moore B.C.J. 2010. AMTAS®: Automated method for testing auditory sensitivity: Validation studies. Int J Audiol, 49, 185–194.
- Margolis R.H., Frisina R., Walton J.P. 2011. AMTAS®: Automated method for testing auditory sensitivity: II. Air conduction audiograms in children and adults. Int J Audiol, 50, 434–439.
- Margolis R.H., Saly G.L., Le C., Laurence J. 2007. Qualind™: A method for assessing the accuracy of automated tests. J Amer Acad Aud, 18, 78–89.
- Rudmose W. 1964. Automated audiometry. J. Jerger, Modern Developments in Audiology. New York: Academic Press.
- Stenfelt S., Reinfeldt S. 2007. A model of the occlusion effect with bone-conducted stimulation. Int J Audiol, 46, 595–608.
- Studebaker G.A. 1967. Intertest variability and the air-bone gap. J Speech Hear Dis, 32, 82–86.
- Swanepoel de W., Biagio L. 2011. Validity of diagnostic computer-based air and forehead bone conduction audiometry. J. Occup Environ Hyg, in press.
- Swanepoel de W., Mngemane S., Molemong S., Mkwanazi H., Tutshini S. 2010. Hearing assessment: Reliability, accuracy, and efficiency of automated audiometry. Telemed J E Health, 16, 557–563.