References
- Bell I., Goodsell S. & Thornton A.R.D. 1980. A brief communication on bone-conduction artefacts. Brit J Audiol, 14, 73–75.
- British Society of Audiology, 2011. Amended 2012. Recommended Procedure. Pure-tone air-conduction and bone-conduction threshold audiometry with and without masking. Reading: British Society of Audiology.
- BS EN ISO 389-3: 1999. Acoustics. Reference zero for the calibration of audiometric equipment - Part 3: Reference equivalent threshold force levels for pure tones and bone vibrators. Geneva: International Organization for Standardization.
- Coles R.R.A., Lutman M.E. & Robinson D.W. 1991. The limited accuracy of bone conduction audiometry: Its significance in medicolegal assessments. J Laryngol Otol, 105, 518–521.
- das Merces R., de Matos B., de Paula Valle S., Dias A.M.N., Mohmensohn dos Santos et al. 2010. Acoustic radiation effects on bone-conduction threshold measurement. Braz J Otorhinolaryngol, 76, 654–658.
- Flamme G.A., Stephenson M.R., Dieters K.K., Hessenauer A., Van Gessel D.A. et al. 2014. Short-term variability of pure-tone thresholds obtained with TDH-39P earphones. Int J Audiol, 53, S5–S15.
- Frank T. & Crandell C. 1986. Bone-conduction thresholds for different bone vibrator types. J Sp Hear Dis, 53, 295–301.
- Frank T. & Holmes A. 1981. Acoustic radiation from bone vibrators. Ear Hear, 2, 59–63.
- Gelfand S. Essentials of Audiology (2nd ed.). New York: Thieme, 2001.
- Harkrider A.W. & Martin F.N. 1998. Quantifying air-conducted acoustic radiation from the bone-conduction vibrator. J Am Acad Audiol, 9, 410–441.
- Hartley B.P.R., Howell R.W., Sinclair A. & Slattery D.A.D. 1973. Subject variability in short-term audiometric recording. Brit J Ind Med, 30, 271–275.
- Hétu C.L.R. 1997. A study of the reliability of automatic audiometry by the frequency scanning method (Audioscan). Audiol, 36, 1–18.
- Lightfoot G.R. 1979. Air-borne radiation from bone conduction transducers. Brit J Audiol, 13, 53–56.
- Lightfoot G.R. & Hughes J.B. 1993. Bone conduction errors at high frequencies: implications for clinical and medico-legal practice. J Laryngol Otol, 107, 305–308.
- Lundgren H. 2010. Bone Conduction Transducers and Output Variability: Lumped-parameter modelling of state variables. Report No. EX042/2010. Department of Signals and Systems, Biomedical Signals and Systems, Chalmers Institute of Technology, Göteborg, Sweden.
- Margolis R.H., Glasberg B.R., Creeke S. & Moore B.C.J. 2010. AMTAS®: Automated method for testing auditory sensitivity: Validation studies. Int J Audiology, 49, 185–194.
- Margolis R.H. & Moore B.C.J. 2011. Automated method for testing auditory sensitivity: III. Sensorineural hearing loss and air-bone gaps. Int J Audiol, 50, 440–447.
- Margolis R.H., Eikelboom R.H., Johnson C., Ginter S.M., Swanepoel D.W. et al. 2013. False air-bone gaps at 4 kHz in listeners with normal hearing and sensorineural hearing loss. Int J Audiol, 52, 526–532.
- Martin F.N., Champlin C.A. & Chambers J.A. 1998. Seventh survey of audiometric practices in the United States. J Am Acad Audiol, 9, 95–104.
- Schaette R., Turtle C. & Munro K.J. 2012. Reversible induction of phantom auditory sensations through simulated unilateral hearing loss. PLoS One, 7, 6, Article e35238. doi:10.1371/journal.pone.0035238
- Shipton M.S., John A.J. & Robinson D.W. 1980. Air-radiated sound from bone vibration transducers and its implication for bone conduction audiometry. Brit J Audiol, 14, 86–99.
- Steiger J.R. 2005. Audiologic referral criteria: Sample clinic guidelines. Hear J, 58, 38–42.
- Stenfelt S., Håkansson B. & Tjellström A. 2000. Vibration characteristics of bone-conducted sound in vitro. J Acoust Soc Am, 107, 422–432.
- Yacullo W.S. 2004. Masking. In: R. Kent (ed.) MIT Encyclopaedia of Communication Disorders. MIT Press, pp. 500–504.