References
- Agilent Technologies (2012). Agilent 85070E Dielectric Probe Kit 200 MHz-50 GHz, Technical Overview. Available online: http://cp.literature.agilent.com/litweb/pdf/5989.0222EN.pdf..
- Chin L, Sherar M. 2001. Changes in dielectic properties of ex vivo bovine liver at 915 MHz during heating. Phys. Med. Biol. 46:197–211.
- Davidson W. 1957. The dielectric properties of Methanol and Methanol-d. Can. J. Chem.. 35 5: 458–473.
- Duhamel F, Huynen I, Vorst A. 1997. Measurements of complex permittivity of biological and organic liquids up to 110 GHz. Microwave Symposium Digest, IEEE MTT-S International. 1:107–110.
- Egot-Lemaire S, Pijanka J, Sulé-Suso J, Semenov S. 2009. Dielectric spectroscopy of normal and malignant human lung cells at ultra-high frequencies. Phys. Med. Biol.. 54:2341–2357.
- Gabriel C, Peyman A. 2006. Dielectric measurement: error analysis and assessment of uncertainty. Phys. Med. Biol.. 51:6033–6046.
- Gabriel S, Lau RW, Gabriel C. 1996. The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. Phys. Med. Biol.. 41:2271–2293.
- Gregory AP, Clarke RN. Tables of the complex permittivity of dielectric reference liquids at frequencies up to 5 GHz. 2012 National Physics Laboratory Report MAT 23. Available online: http://www.npl.co.uk/content/ConPublication/4295.
- Guide to the Expression of Uncertainty in Measurement, published by the International Organisation for Standardisation (ISO), Geneva, Switzerland, ISBN 92-67-10188-9.
- Jordan BP, Sheppard RJ, Szwarnoski S. 1978. The dielectric properties of formamide, ethanediol and methanol. J. Phys. D: Appl. Phys.. 11:695–701.
- Lazebnik M, Converse MC, Booske JH, Hagness SC. 2006. “Ultrawideband temperature-dependent dielectric properties of animal liver tissue in the microwave frequency range. Phys. Med. Biol.. 51:1941–1955.
- Levin VV, Podlovchenko TL. 1971. Dispersion of the dielectric permittivity of ethylene glycol. J. Struct. Chem.. 11 4: 708.
- Peyman A, Rezazadeh AA, Gabriel C. 2001. Changes in the dielectric properties of rat tissue as a function of age at microwave frequencies. Phys. Med. Biol.. 46:1617–1629.
- Peyman A, Gabriel C, Grant EH. 2007. Complex permittivity of sodium chloride solutions at microwave frequencies. Electromagnetics. 28:264–274.
- Peyman A, Holden S, Gabriel C. Dielectric properties of tissues at microwave frequencies. Mobile telecommunications and health research (MTHR) programme. Report. 2009.
- Simon CJ, Dupuy DE, Mayo-Smith WW. 2005. Microwave ablaiton: principles and application. Radiographics. 25 1: S69–S83.
- Taylor BN, Kuyatt CE NIST Technical Note, 1297, 1994 Edition Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results..